Rated Flow Range: 501 (5 to 500 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: R (w/Bracket), Calibration Certificate: A (Yes)
Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: W (w/Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min
Adjustment Valve, Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: L (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04
Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: L2 (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: None), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes)
Valve; w/Stop Valve), Return Unit Flow Range: 20 (2 to 16 L/min), Supply/Return Port Size: 04 (1/2)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes)
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: EB (EtherNet/IPâ„¢ - 16 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 04 Stations, P, E Port Location: U (U Side), SUP/EXH Block: R (External Pilot), A, B Port Size: N7 (ø1/4" One-touch Fitting), Mounting: A (DIN Rail Mounting, Name Plate, w/Station Number)
Body Size: 32, Pilot Type: 2 (Internal Pilot Solenoid), Port: 04 (1/2), Thread: N (NPT), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style or None
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 9 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2), Thread: N (NPT)
Fitting: 11 (Size 1), Tubing Size: 04 (ø4 x ø3)
Function: 1 (2 Position Single), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 04 (Sub-plate Plug-in
Compressor Output 10HP, (7.5kW)], Thread: N (NPT), Port Size: 04 (1/2), Accessory: None, Auto Drain: C (N.C. Auto Drain), Rubber Material: Standard, Air Pressure: Standard, Drain Guide: None, IN-OUT Direction: Standard, Pressure Switch 125VAC, 30VDC: None, Element Service Indicator: T (Yes)
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread: T (NPTF)
10 orifice dia.) , Normally closed (N.C.) , Port size: 01 (1/8), 02 (1/4), 03 (3/8), 04 (1/2), Pilot port thread: Rc, NPT VALVE. VALVE. FLUOROPOLYMER. .88184 lb.
3), 04 (?4), 06 (?6), 08 (?8), 10 (?10), 12 (?12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") VALVE. VALVE. FLUOROPOLYMER. .22046 lb.
10 orifice dia.) , Normally closed (N.C.) , Port size: 01 (1/8), 02 (1/4), 03 (3/8), 04 (1/2), Pilot port thread: Rc, NPT VALVE. VALVE. FLUOROPOLYMER. .15521 lb.
3), 04 (?4), 06 (?6), 08 (?8), 10 (?10), 12 (?12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") VALVE. VALVE. FLUOROPOLYMER. .32262 lb.
Function: 1 (2 Position Single), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 04 (Sub-plate Plug-in Terminal 1/2, Non Plug-in