270 F 823 G 3 H 797 J 620 AMF801 AMF901 445 12B 570 300 520 1093 3 867 AMF800/900/1000 ORIENTATION holes Label Drain Model Connection (Flange) 2B 8B C 2B, 3B, 4B 500 A 330 B 300 D 1070 E 1200 F 1290 G 20 H 720 M16 x l400 Anchor bolt M20 x l500 AMF800 AMF900 400 550 560 745 300 300 1070 1090 1230 1320 1335 1450 24 24 4B, 6B 870 M20 x l500 AMF1000 14-20-48
/PL / OSSD SIL 2 2 2 3 3 3 3 3 SIL CL 2 2 2 3 3 3 3 3 * 2 2 4 3 4 ** 4 3 Cat. 3 PL d d d e d e e d *:Cat. 3 EN13849-2 2 N.O. **:Cat. 18 No.EX##-OMY0006CN 3.3.8. SI 0 SI 0 A SI 1. 2.I/O 3.SI 4. 5. 10 0 I/O 0 "0"= SI 72 72 SI 72 SI SI 16 SI SI SI SI 0 16 19 No.EX##-OMY0006CN SI SI SI 16 SI SI 20 D 3.3.9. GSDMLFDCML 3.4.
ZSP AWG24-26 (0.14 to 0.2 mm2) AWG24-26 (0.14 to 0.2 mm2) AWG20-22 (0.3 to 0.5 mm2) AWG20-22 (0.3 to 0.5 mm2) PSE510, PSE530 ZS-26-E ZS-26-E-1 ZS-26-E-2 ZS-26-E-3 ISA2 1.4 to 2.0 PSE521 1.0 to 1.4 IS PSE520 1.4 to 2.0 Refer to the following diagram for connecting Series PSE520 to the connector. ZSM PF2 Brown Black Blue N.C. 1 2 3 4 IF Data F.G.
NCMB 075-0400-XB7 ---E-Low tgmperatule Alto-switch capable not avaitable. (E Air Cvlinder Stainlesg Stel Cylinder Series NCM RodBoot sl,c' . Boots are supplied to protect the surface of pigton rod end rod seals in harsh or wet environmenl. . Borc size %.%.1%s,1%.1lz . Action/Double acting only HOWTO ORDER Boot lleterbl %'%'114a Er.)
2 u r e q w No. q w e r t y u i o !0 !1 !2 !3 !4 !5 !6 !7 !8 !
(Use an auto switch rated 24V DC, with a minimum amperage capacity of 10mA.) q q q w w w e e e r (Unit: N) Bore size (mm) 40 50 63 80 100 Operation r Min. sensing weight 26 40 62 100 160 Warning Back-up of the balance pressure data The balance pressure data is backed up by the controller for approximately 5 minutes during a power outage or when the power supply has been turned OFF.
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 450mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewied Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 350mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: Y7BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 1000mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 1000mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: P5DW--Solid State, 2-color Indication, Magnetic Resist., 2 Wire, Lead Wire or Prewied Connector: 3m, Number: 4 pcs.
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 1200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: F5BA--Solid State, Water Resist., 2 Wire, Lead Wire or Prewied Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: B54--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: B54--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: B54--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: 1 pc.
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 175mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: F59F--Solid State, Diagnostic, 4 Wire NPN, Lead Wire or Prewied Connector: 0.5m (Or None in the Case of No Switch), Number: 3 pcs.
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 175mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewied Connector: -, Number: -