AC PB0111-3 (PB0111) DC Manual override (With lock) PB0111-1 Manual override (Non-locking) PB0101 PB0101-1 Note) There is polarity of (1) +, (2) . ( ): With indicator light 4-16-2 3 Series VS3115/3110 Dimensions Body ported VS3115-G VS3115-D 2-6 mounting hole 2-6 mounting hole V100 SY SYJ G 1/2 (Cable 8 to 10) Manual override Manual override VK VZ Courtesy of Steven Engineering, Inc.-230
AR40P-270AS AR30P-270AS AR40P-270AS Set nut AR40P-260S AR30P-260S AR40P-260S G46-10-02 Round Square embedded type Round Square embedded type G46-10-02 G36-10-01 1.0MPa Note 3) GC3-10AS Note 2) GC3-10AS GC3-10AS 1 4 1 8 1 4 Note 1) Pressure gauge G46-2-02 G36-2-01 G46-2-02 Set pressure + 0.05MPa (at relief flow rate of 0.1l/min(ANR)) 5 to 60C (With no condensation) 5m 0.2MPa Note 3) GC3-2AS
Symbol Stations 02 24 Symbol Stations 02 24 D side U side 1 3 2 Stations 2 stations 24 stations 2 stations 24 stations Up to 24 solenoids possible. PG: Flat ribbon cable (20 pins) PH: Flat ribbon cable (10 pins) SUP/EXH block (D side mounting) Note Up to 18 solenoids possible. Note Up to 8 solenoids possible.
Manual override VQC 1/2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 2-position double 3-position exhaust center Nil: Non-locking push type (Tool required) B: Locking type (Tool required) C: Locking type (Manual) (A) 4 (B) 2 (A) 4 (B) 2 VQC 4/5 Metal 4 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQZ 2 2-position double 3-position pressure center (A) 4 (B) 2 (A) 4 (B) 2 Rubber SQ 5 1 (P) 5 (R1) 3 (
(at 25 oC) Model PSE57-02 PSE57-02-28 Fluid Applicable Gas or liquid that will not attack or corrode the materials of parts in contact with fluid Power supply voltage 12 to 24 VDC10% with 10% voltage ripple or less Electrical spec.
Minimum operating pressure 0.02 MPa ASN Ambient and fluid temperature 5 to 60C (No freezing) AQ JIS Symbol Flow Characteristics ASV AK2000-01/-02 AK4000-02 AK How to Order Pressure drop (MPa) Pressure drop (MPa) Pressure drop (MPa) Pressure drop (MPa) ASS Inlet pressure: 0.1 MPa Inlet pressure: 0.1 MPa Inlet pressure: 0.1 MPa AK 2 000 02 0.5 MPa 0.7 MPa 0.5 MPa 0.3 MPa ASR 0.3 MPa 0.7 MPa
Metric sizes Type 04 06 08 10 12 4 6 8 10 12 2 Elbow Control type 0 1 Meter-out Meter-in Port size M5 01 02 03 04 M5 x 0.8 1/8 1/4 3/8 1/2 With One-touch fitting Clean specifications Metal parts material Q G Brass (electoless nickel plated) Stainless steel 304 Needle Valve/Flow Characteristics AS121FP-M5 AS221FP-01 AS221FP-02 08,10 06,08 06 04 04 AS321FP-03 AS421FP-04 12 10 10,12 08 06 15
Regulator for 2 MPa ARX 20 How to Order ARX2 0 01 Regulator Options None Nil 1348112 G36 10 01 G46 10 02 G36 4 01 G46 4 02 G36 P10 N01 G46 P10 N02 G36 P4 N01 G46 P4 N02 1348110A B Regulating pressure range Bracket 0.05 to 0.85MPa 0.05 to 0.30MPa 0 1 ARX20 Nil F ARX21 Nil F Thread type G Pressure gauge Rc NPT G Nil N F ARX20N ARX21N P Port size Panel nut 1/8 1/4 01 02 Option
Note 2) AS1000, AS2000 are not applicable. 8 3 2 1 Bore size 2 1 Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 AS1000 AS1000 AS2000 AS2000/3000/4000/5000 AS3000/4000/5000 AS4000/5000 Thread type Nil Metric thread (M3, M5) Rc NPT G N F Caution Be sure to read before handling.
(N specifications) How to Order AS4200-04 AS3200-03 01 S AS 2 2 0 0 AS2200-02 AS2200-01 Option Body size AS1200-M5 None With seal Nil 1 2 3 4 M3, M5 standard S K N 1 8 1 4 , standard standard standard AS1400-M3 Hexagonal lock nut 8 3 Electroless nickel plated 2 1 If more than one option is required, write option part numbers in the order of S, K, N.
(mm) Universal type Port size in the cylinder side 6 8 12 10 4 (1) AS22 1FE-01 AS23 1FE-01 R 1/8 AS22 1FE-02 AS23 1FE-02 R 1/4 AS32 1FE-03 AS33 1FE-03 R 3/8 AS42 1FE-04 AS43 1FE-04 R 1/2 Note 1) Elbow type only Note 2) Distinction between meter-out/meter-in types by appearance Those are distinguished by the lock nut.
Symbol How to Order 2 1 01 06 2 AS 1 F E S K JIS Symbol Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Applicable tubing O.D. (mm) 04 06 08 10 12 Type 4 6 8 10 12 Port size Elbow Universal 2 3 01 02 03 04 R 1/8 R 1/4 R 3/8 R 1/2 Control type Meter-out Meter-in 0 1 With residual pressure release valve With One-touch fitting 15-9-36
Nil Metric thread (M3, M5) Rc NPT G N F Bore size Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 1/8 1/4 3/8 1/2 AS1000 AS1000 AS2000 AS2000, 3000, 4000, 5000 AS3000, 4000, 5000 AS4000, 5000 650 A
EXH. port Silencer part no. 06 AN10-C06 07 AN10-C07 08 AN15-C08 09 AN15-C08 10 AN20-C10 11 AN20-C11 12 AN30-C12 ZHP ZU Female threads Metric size Inch size 01 Rc1/8 N01 NPT1/8 02 Rc1/4 N02 NPT1/4 03 Rc3/8 N03 NPT3/8 04 Rc1/2 N04 NPT1/2 VQD-V Standard bracket Note Refer to Table 1 and Table 2 for the combination available for SUP., VAC. and EXH. port connection.
Regulator with Mist Separator AMR3000 to 6000 Series (Part number for one piece) How to Order Adapter Assembly 03 AMR 4 0 00 02 E 3 Auto-drain Pressure gauge mounting Port size 02 03 04 06 10 ARJ 1 None With auto drain 0 MR unit Flow direction: Right to left Nil Flow direction: Left to right Applicable model 1/4 3/8 1/2 3/4 1 Nil E2 E3 E4 E6 E10 R 3 4 5 6 AMR3 00-02 to 03 AMR4 00-02 to 04
(A contact) 1 2 1 pc. 2 pcs. 6 6 pcs.
(Not applicable to Gateway unit) VQ7 Connector type manifold Connector wiring diagram (Mixed wiring) 6 A 4 A 3 A 1 A 5 B 2 B Output The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 5 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 5 6 7 8 9 10 All kits use multi-pin
INSTALLATION 2 1 to 2 6 2.1 Installation direction and clearances . 2 2 2.2 Keep out foreign materials . 2 3 2.3 Cable stress . 2 4 2.4 SSCNET cable laying. 2 4 2.5 Inspection items . 2 6 2.6 Parts having service lives . 2 6 3.
Applicable fluid 1 Model Air Water Oil Steam Medium vacuum For Air For Air VX2 0 Page 5 2 For Medium vacuum For Medium vacuum VX2 4 Page 10 2 For Water For Water VX2 2 Page 14 2 2 For Oil For Oil VX2 3 Page 16 Can be used with heated water. 2 2 2 For Steam For Steam VX2 5 Page 18 1 For details, refer to pages 45 and 46. 2 Refer to the individual specifications for each fluid.