To operate a relay as a load, use the relay shown in the table below or the equivalent, in order to extend the life of the switch. qWhen handling the product, do not drop an object on it, gouge it, or apply an excessive impact on it. wDo not operate it in an area in which a large amount of magnetism is present.

Origin Home Switch Infotmation LX series actuators are available with an optional photo micro sensor as an origin home switch to detect when the actuator is fully retracted. The LCOC seies positioning drjver requires an input from the origin home switch or some other sensor when homing the actuator.

VVQ5000-25A1 5 Intermediate stop Drop prevention Can hold an intermediate cylinder position for an extended time. When combined with a double check spacer with built-in double check valve, it is unaffected by air leakage between the spool valves, making it possible to hold a cylinder at an intermediate stopping position for an extended time.

When the hydraulic pressure of an air-hydro unit must be raised. 7. When the pressure must be raised in an explosion-proof environment. 8.

Install an after-cooler, air dryer or water separator, etc. Air that contains excessive drainage can cause malfunction of valves and other pneumatic equipment. To prevent this, install an after-cooler, air dryer or water separator, etc. 3. Use the product within the range of specifications for fluid and ambient temperature.

DNote) When the digital filter setting (ON/OFF) is changed, an error count will occur. Reset the count value.

Wa = 1 x 1.2 = 1.2 Allowable load weight coefficient b: Graph (1) = 1 Max. allowable load weight Wmax: Table (2) Wmax = 1.2 1 = 0.2 / 1.2 = 0.17 1 = W/Wa Find the load factor of the load weight 1. 3-2 Load Factor of the Static Moment M = W x 9.8 (Ln + An)/1000 Moment center position distance compensation amount An: Table (3) Find the static moment M (Nm). Examine Mr.

An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 1.

Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 2. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause a malfunction of pneumatic equipment such as valves.

As a guide, an acceptable tightening level is reached by tightening the screw an additional 90 degrees (1/4 turn) from the point at which the screw is snug. (Refer to Figure 3.)

H G I J K L A B C D E F M R Size Tolerance +0.058 0 -0.1 -0.2 -0.1 -0.2 -0.1 -0.3 -0.1 -0.3 AD-FI-20 AD-FI-25 AD-FI-32 AD-FI-40 +0.027 0 +0.027 0 +0.027 0 +0.027 0 9 9 16 16 36 38 55 55 16 18 22 22 9 9 12 12 20 25 32 40 10 10 15.5 15.5 20 20 24 24 14 14 20 20 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 20 25 32 40 46 46 56 64 28 30 40 43 60 60 80 88 22 22 30 30 16 16 16 24 10 10 12 12 30 30

How to manually change from an unlocked state to a locked state To change from an unlocked state to a locked state: Unlike the procedure for manually disengaging the lock, never rotate the pin by striking it, as it could bend or damage the pin. The lock is disengaged at the time of shipment.

The unit body can be fixed by tightening four holding bolts evenly at an arbitrary position. However, there is a possibility that the adjustment mechanism will be tilted due to high impact energy. Since the holder mounting bracket for adjustment is available as an option for -X416, -X417, we recommend that you use it.

Rod end thread type is an optional product. (Refer to page 281).

Please contact SMC if hysteresis causes an operational problem.

solid state auto switch is available after receiving an order. 18

Do not use the air cylinder as an air-hydro cylinder. The use of turbine oil as a fluid for an air cylinder may result in oil leakage. 4. The oil stuck to the cylinder is grease. 5. The base oil of the grease may seep out.

With air cushion FT F 4 x FD 0 E0.05 FX0.15 B B FX0.15 (mm) Bore size 40 B 61 E 25 F 2 FX 46 FD 6.6 FT 8 50 63 76 92 30 32 2 2 58 70 9 11 9 9 Note) End boss is machined on the flange for E. Other dimensions are the same as basic type.