Note 2) The dimensions (A + stroke) and (B + stroke) for 10 mm stroke will be the same as those for 15 mm stroke.
As viewed from the end of the rod, the pin is tilted 15 to the left of the center. 3. Supply an air pressure of 0.3 MPa or more to the unlocking port. 4. Rotate the pin 30 to the right with a wooden implement such as the grip of a wooden hammer or a resin stick without scratching.
Port 2 (A) pressure (MPa) Port 2 (A) pressure (MPa) 0.8 0.8 0.8 0.7 0.7 0.7 0.6 0.6 0.6 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 VY1D00-5 VY1B0-5 VY120-5 1 0 1 2 3 4 5 0 1 2 3 4 5 V V V 0 1 2 3 4 5 A VY1D00-6 VY1B0-6 VY120-6 A 1 1 1 1 0 2.5 5 7.5 10 0 2.5 5 7.5 10 V V V 0 2.5 5 7.5 10 VY1D00-7 VY1B0-7 VY120-7 1 A 4 0 8 12 16 20 mA 4 0 8 12 16 20 mA 4 0 8 12 16 20 mA 2 2
Use 0.3 to 0.7 times the thrust (differs depending on the operating speed) as a guide for actual use. g: Gravitational acceleration Dynamic Moment M1 Mounting orientation Dynamic load FE Horizontal Ceiling Wall Vertical Z a 1.4a x x mn x g a 1 3 x FE x Z M1E Dynamic moment Dynamic moment M2E is not generated.
As a rule, it should be turned about 90 past the point at which tightening can be felt.
Use this as a guideline purpose only for model selection because the value varies depending on the material and/or size of a subject.
The proper tightening torque for pipe fittings is as shown in the table. As a rule, they should be tightened 2 to 3 turns with a tool after first tightening by hand. Be careful not to cause damage by over-tightening. Note) Use Series AS-F with -X214 for the throttle valve.
*Loctite 542 (medium strength) or equivalent 2.50 or larger bore size cylinders cannot be dis-as-sembled. When disassembling cylinders with bore sizes of 20 through 40, grip the double flat part of either the head cover or the rod cover with a vise and loosen the other side with a wrench or a monkey wrench, etc., and then remove the cover.
Through the availability of a wide range of series in terms of converter capacity and valve unit flow rate control capability, speed as high as 200 mm/s (throttle valve) can be achieved with a 80 cylinder.
If a magnetic substance is closer than 2.5mm, auto switches may malfunction due to a drop in magnetic force. If this surface is to be used for mounting, a spacer composed of a nonmagnetic substance (aluminum, etc.) is required as shown in the figure below.
Note 2) Allowable rotating torque, and operating range when used as a lifter, are the same as MGPWL series.
Pressure (including vacuum) holding It is not usable for an application such as holding the pressure (including vacuum) inside of a pressure vessel because air leakage is entailed in a valve. 8. When the conduit type is used as equivalent to an IP65 enclosure, install a wiring conduit, etc. 9.
Station 3 2 1 D side U side Stations 02 03 2 stations 3 stations 20 20 stations Note) Maximum of 20 stations Electrical entry Grommet/Plug lead C How to Order Valve S070 A 5 B G Electrical entry Body type Body type Base mounted with clips Symbol A G C Grommet Plug lead with light/surge voltage suppressor Coil voltage Power consumption Pressure specification Flow rate 24 VDC 12 VDC
Actuator drive When an actuator, such as a cylinder, is to be driven using a valve, take appropriate measures to prevent potential danger caused by actuator operation. 5. Pressure (including vacuum) holding It is not usable for an application such as holding the pressure (including vacuum) inside of a pressure vessel because air leakage is entailed in a valve. 6.
) 2-4.5 (mounting holes) 67.5 59 19 17 2 R P P R 34 2.3 7 20 Pg.7 4-Rc(PT) 1/8 (ports P, R) A A A P = 19 13.5 L2 L1 4 1 7 8 26 47.5 Approx. 300 (lead wire length) n-Rc(PT) 1/8, M5 x 0.8 (port A) 7 20 34 2-4.5 (bracket mounting holes) 4-M3 x 0.5, depth 6 (bracket mounting screws) 7 8 47.5 15.5 20 25 49 4 L3 7 7 L: Dimension table n: Stations n L 1 35 27 13 2 54 46 32 3 73 65 51 4 92 84 70
Stations PFA Port size Orifice diameter 3/8 1/2 3/4 1/4 Valve type Symbol Type 8 12 20 4 Basic type N.C. P P P Stations are counted from station 1 on the left side, with the A (OUT) ports in front. PA PB PA P PB A A A N.O. PA PB PA A (OUT) port PB A A A Double acting N.C. N.O. Double acting
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
Note 3) When tightening an auto switch mounting screw (M2.5), use a watchmakers screwdriver with a grip diameter of 5 to 6 mm. Also, set the tightening torque to be 0.05 to 0.15 Nm. As a guide, turn 90 from the position where it comes to feel tight.
Avoid especially the application of pressure above specifications through a water hammer.
For AIR EXH: AN20-02 (: Either Nil or N is entered as a thread symbol.)