SMC Corporation of America
Elite Part Number Search
Search Results "ISE20-P-M5-K"

Note 4) Except valve weight 20 Series SQ1000/2000 SQ1000/Flat Cable Kit Stations SS5Q13JD0 L4 L3 5.25 L2 49.5 47 10.3 L1 M5: External pilot port Indicator light P = 11.5 19.2 47.8 25 20.5 1.5 1.5 Manual override (mounting hole dimension) 113 {double (double solenoid) dual 3 port valve} 108.5 {single, double (latching)} 34 10 4.6 122 (3 position) (108.5) A A A B A B A 2.PUSH 2.PUSH 94 1.TURN

0.2 MHZ2-16D 7 4 M5 x 0.8 M5 x 0.8 M5 x 0.8 14.9 20.9 6.6 12.6 11.6 2.1 4 MHZ2-20D 9 5 M5 x 0.8 M5 x 0.8 M5 x 0.8 16.3 26.3 7.2 17.2 14 2.1 4 MHZ2-25D 6 12 M5 x 0.8 M5 x 0.8 M5 x 0.8 19.3 33.3 8.8 22.8 19 3.5 4 Note) Through-hole mounting is not possible for 10. 925 Standard Type / Series MHZ2 Finger Option 1122Air Preparation Equipment Pressure Control Equipment Flow Control Equipment

A AA C J L L J K (4 locations) Flat washer With 4 pcs.

Pin name 1 2 3 4 DC (+) OUT2 DC () OUT1 1 3 2 x Piping port Z U T S 4 x WX G 2 4 (35.5) 42 H For PF3W721 OUT IN AA G 4 x P K L 2 x Piping port G N DD PF3W504/520/540/511/521 Remote sensor unit Y A E J F 30 W B V 2 x Piping port Z S T U 4 x WX G H 42 (35.5) For PF3W521 IN OUT AA G 4 x P K L 2 x Piping port G N (mm) Bracket dimensions Model Port size A AA B D DD E F G H J K L N P (Rc, NPT,

(mm) Type Port size Model Type Port size Model KQ2H04-M5 KJH04-M5 Male connector Male connector 4 M5 x 0.8 KQ2S04-M5 4 M5 x 0.8 KJS04-M5 Hex. socket head male connector Hex. socket head male connector KQ2L04-M5 KJL04-M5 Male elbow Male elbow Miniature Fitting/Series M Tubing O.D.

adjustment screw Note 3) (inner cover) Plug Plug [P (port e)] [P (port c)] A A LW Plug Operating direction P (port a) P (port b) Auto switch mounting groove [P (port g)] 0.5 Note 2) 0.5 Note 2) Left Right Plug [P (port h)] HI HP H HL HG HT HS HB HA HB HA HG HT HI WB 4-J Depth JK Plug [P (port f)] WB WA TA TA WA R TB Plug TB R W [P (port d)] Inner cover Note 3) holding screw (mm) K 21 20

A R JS20, 32, 40, 63 Center of sphere M M U U D J F H B E G P R A Max. thread depth P Model Center of sphere R Allowable eccentricity U Max. operating tension and compression force (N) (mm) M A B C D E F G H J JS10-4-070 JS16-5-080 0.5 0.5 0.5 0.5 0.75 1 4.7 5.8 7.3 8.5 11.6 14.3 M4 x 0.7 M5 x 0.8 26 34.5 8.5 12 15.5 17.5 18.5 23 9.5 13.5 12 16 21 24 31 41 1.5 2 4.5 5 5 7 4 6 7 8 11 14 4

A R Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com JS20, 32, 40, 63 Center of sphere M M U U D J F H B E G P R A Max. thread depth P Model Center of sphere R Allowable eccentricity U Max. operating tension and compression force (N) (mm) M A B C D E F G H J JS10-4

GC1 MM1 KA (manual unlocking unit) Dust cover NH1 M(D)LUB25,32 (Extension locking) K H2 P ZZ1 + Stroke GB GA Unlocks when pressurized BP unlocking port Front cylinder port GC D GW GY NH (manual unlocking unit) Dust cover P Rear cylinder port NS + Stroke NG NF NJ NJ NI Width across flats KA MM Width across flats B1 EY EY NY C H1 AL 4-ND through 4-ET B A NB NA K 2 x 4-NC counter bore Prepared

NA K 2 x 4-NC counterbore Prepared hole diameter NE H S + Stroke ZZ + Stroke BY BB BS + Stroke BA 2-BT (mm) Stroke range Model A BY D GW GY H H1 B1 C B AL BA BB BP BS BT ET GA GA1 GB GC GC1 EY 22 26 30 35 19.5 23.5 27 32 24 28 32 39 8 6.5 9 12 9 6.5 8 10 17 19 22 27 MLUB25 MLUB32 MLUB40 MLUB50 M5 x 0.8 73 87 87 102.5 M5 x 0.8 depth 7.5 M6 x 1 depth 12 7 8 9 9 12 14 16 20 M5 x 0.8 depth 11

S 55 58 60 74 75 P M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 NY 26 28 36 42 46 NX 6 6.5 8 10 11 NC 7.5 depth 4.5 9 depth 5.5 10.5 depth 6.5 13.5 depth 8.5 17 depth 10.5 MM M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 M18 x 1.5 NS 43 45 44 54 53 N 14 15.5 16 21.5 21.5 KA 10 12 14 18 18 ND M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 M12 x 1.75 NE 4.3 5.1 6.9 8.7 10.5 ZZ 69 72 75 92 96 Model MUB25 MUB32 MUB40

S 55 58 60 74 75 P M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 NY 26 28 36 42 46 NX 6 6.5 8 10 11 NC 7.5 depth 4.5 9 depth 5.5 10.5 depth 6.5 13.5 depth 8.5 17 depth 10.5 MM M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 M18 x 1.5 NS 43 45 44 54 53 N 14 15.5 16 21.5 21.5 KA 10 12 14 18 18 ND M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 M12 x 1.75 NE 4.3 5.1 6.9 8.7 10.5 ZZ 69 72 75 92 96 Model MUB25 MUB32 MUB40

F with effective thread depth G F with effective thread depth G Q Q R D R H E E 4-K through 8-L counter bore 4-K through C B + Stroke J J 8-L counter bore A + Stroke M M CHKDB20 & 25 CHKDB32 to 100 Width across flats f c a b g e h + Stroke Rod end male thread (mm) F L A B C D E G H J K M P Q R Bore size (mm) 20 M8 x 1.25 9.5 depth 5.4 51 43 8 12 10 10 6 30 5.5 43 1/8 16.5 6 25 M10 x 1.5 9.5

mode] In the 3 step setting mode, the set value (P or n) and hysteresis (H) can be changed.

-RA Both ends tapped (CQMA) (mm) Without auto switch With auto switch Stroke range (mm) Bore size (mm) P P EA EB EC B F Q A B F Q A TN TF NN NN TN TF 5 5.5 11.5 M5 x 0.8 M5 x 0.8 40 23 32 10 to 50 50 33 7.5 10.5 45 43 34.4 Rc1/8 NPT1/8 NPT1/8 G1/8 7.5 10.5 G1/8 Rc1/8 NPT1/8 NPT1/8 75, 100 50 33 5 to 50 46.5 29.5 40 Rc1/8 NPT1/8 NPT1/8 G1/8 8 11 G1/8 56.5 39.5 8 11 52 50 41.4 Rc1/8 NPT1

Screw lightly the auto switch mounting screw (M5 x 0.8 x 16 L). 4. Set the whole body to the detecting position by sliding, tighten the mounting screw (M5 x 0.8 x 16 L) to secure the auto switch. (The tightening torque should be about 2 to 3 Nm.) 5. Modification of the detecting position should be made in the state of 3. Auto Switch Mounting Bracket Part No.