1.3 x 10-10 P.526 XVD2-02S 522 Smooth Vent Valve (Supply Line) XVD Series RoHS How to Order 02 XVD 2 V Fitting type Smooth vent valve V S For VCR For Swagelok Space-saving Valve / needle valve integrated construction requires only 1/4 the piping space of previous models.

For the function, refer to P.5-29,P.5-30 [Temperature range monitoring function setting example]. Temperature range monitor start time HRR Series 5.5 Advanced setting mode 5-31 HRX-OM-X071 Chapter 5 Display and Setting of Various Functions 24. Press the [] key.

Unit switching Real-time switch output ( ) For air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES CFM x 10-2, CFM x 10-1 ft3 x 10-1 OFF P-1 P-2 High flow rate CFM=ft3/min "P" Window comparator mode H : Hysteresis High Flow Rate Type (For Air) H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON NO OFF P-1 P-2 ft3, ft3 x 103, ft3 x 106 CFM

VER2000 is V type. (Refer to Best Pneumatics Vol. 3 for further information.)

Hysteresis 0 to variable 7 Withstand pressure 600 kPa Detection nozzle 1.5 4 Current flow 5 L/min or less 12 L/min or less 22 L/min or less Power supply voltage 24 VDC 10%, Ripple(p-p) 10% or less (with power supply polarity protection) Current consumption 25 mA or less Switch output 2 output (NPN or PNP) Max. load current 10 mA Max. applied voltage 26.4 V Residual voltage 1 V or less (at

RUN1 input circuit at external input operation v Note) : This circuit is not necessary for READY signal. Controller (VYU5-D) External appearance of exclusive controller RUN1 STOP START SEL. SW RESET RUN2 RUN1 OV INPUT 6 7 5 8 4 + 9 3 SET UP A 2 B 1 0 C D 1 E F 0 to 10V V R 1 OUTPUT SET UP BALANCE CONTROLLER VYU5-D 2 V R 2 OV ERR.

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread)

Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread)

Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread)

For the function, refer to P.5-29,P.5-30 [Temperature range monitoring function setting example]. HRR Series 5.5 Advanced setting mode 5-31 HRX-OM-X084 Chapter 5 Display and Setting of Various Functions Temperature range monitor start time 24. Press the [] key.

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -