The maximum number of stations is determined by the total number of solenoids.
Take measures to prevent the danger caused by the actuator's movements. 10. Ventilation When a valve is used inside a sealed control panel, etc., provide ventilation to prevent a pressure increase caused by exhausted air inside the control panel or a temperature increase caused by the heat generated by the valve. Caution 1.
We discovered that, by maximizing the fluorine content of their FKM, the swelling was reduced. Further enhancement of the physical properties was made by removing the traditional colorant and adding carbon black. Therefore, the normal color of this new FKM is black.
An autoswitch can be mounted to indicate operation of the buffer, operated by a magnet on the piston. By reversing the direction of the switch, NO or NC operation is achievable.
The circulating fluid is sent to the heat exchanger by the pump, and is controlled to a set temperature by the refrigeration circuit, to be discharged to the customer system side again by the thermo-chiller.
When there is such a dangerous case to be touched by hands directly, install a protective cover.
Note that is occupied by 2ch. The name of analog signal without "+" will be 16bit data. No.
Turn the manual override clockwise by 180 to set the mark to A and press it in the direction indecated by the arrow. It will be locked set in a (Passage: P A) state. Turn the manual override counterclockwise by 180 to set the mark to B and press it in the direction indicated by the arrow. It will be reset in a (Passage: P B) state. (It is reset when shipped.)
Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires. This may not only cause broken lead wires, but it may cause internal elements of the switch to be damaged by the stress. 3. Mount switches using the proper tightening torque.
Moreover, due to the fact that bumpers are installed at each end of the piston, overall length is increased by 6mm for 32 and 40, 8mm for 50 and 63, and by 10mm for 80 and 100.
The encoder count value is converted into units [mm] by multiplying the count value by the encoder resolution of the used Card Motor model.
Use caution particularly when lifting items such as glass plates and circuit boards, because a large force will be applied by the wind pressure. When a workpiece which is oriented vertically is transported horizontally, large forces are applied by acceleration when movement is started and stopped.
The port A pressure is fed back to the control circuit by the pressure sensor.
state transition command is sent by setting Bit0-3 and Bit7 of Controlword (6040h).
The manual has been written to be used by trained and competent personnel.
(P2+0.1013) Calculation by Cv factor Q=1972.8.Cv.
Shallow scratches caused by sliding 1. Inside surface of tube Deep scratches Caused by sliding Replace it with new one when it cant be repaired. Scratches caused by seizing Replace with new one. Sliding face of rod Stripping Replace with new one. No problem with operation. Rub them with paper, etc. slightly. Shallow scratches caused by sliding 2.
Has large retaining force while holding force is increased by the collet.
The circulating fluid is sent to the evaporator by the inverter pump, and is controlled to a set temperature by the refrigeration circuit, to be discharged to the users equipment side again by the thermo-chiller.