Indicator light Lead wire Flexible fluorine resin heavy-duty cable, 6, 0.5mm2, 2 cores, 300 mm Impact resistance Switch part : 1000 m/s2, Connector part : 300 m/s2 Insulation resistance 50 M or more at 500 VDC (between lead wire and case) Withstand voltage 1000 VAC for 1 minute (between lead wire and case) Ambient temperature 10 to 60C Enclosure IEC529 standard IP67, JIS 0920 Watertight
VQZ100/200/300 Body Ported How to Order Valve VQZ200/300 VQZ 2 1 2 5 M C6 Series 2 3 VQZ200 Body width15mm VQZ300 Body width18mm Bracket F None With bracket SY SYJ Configuration VK Port size {2(A)port} (A) 2 N.C.
150 150 150 320 400 70 94 58 65 200 200 480 610 220 220 225 238 Model HAA15 HAA22 B C D E F G H J K L M N P Q R S 1B union union 1 2 B 1 HA AT ID AMG AFF AM Misc. 14-15-3
frequency [c.p.m] Weight [g] Model Bore size [mm] MHL2-10DZ 60 20 56 76 280 MHL2-10D1Z 40 40 78 118 355 10 MHL2-10D2Z 60 96 156 430 MHL2-16DZ 60 30 68 98 525 MHL2-16D1Z 40 60 110 170 725 16 MHL2-16D2Z 80 130 210 845 MHL2-20DZ 60 40 82 122 940 MHL2-20D1Z 40 80 142 222 1335 20 Symbol MHL2-20D2Z 100 162 262 1520 Double acting: External grip Double acting: Internal grip MHL2-25DZ 60 50 100 150
When the arms moment of inertia is 1 x 103 kgm2, cylinder speed should be MK20/25: 82 mm/s or less, MK32/40: 150 mm/s or less. For calculating the moment of inertia, refer to page 387. Note) Maximum piston speed is equivalent to approximately 1.6x the average piston speed. (Rough indication) Note) Use 63 within a pressure range from 0.1 to 0.6 MPa.
Stroke Table Long strokes (mm) Max. manufacturable stroke (mm) Bore size (mm) Standard strokes (mm) Note 1) Lock Unlock 20 25, 50, 75, 100, 125, 150, 200 201 to 350 25 301 to 400 32 301 to 450 25, 50, 75, 100, 125, 150, 200, 250, 300 40 1500 301 to 800 50, 63 301 to 1200 80 301 to 1400 Locked condition Unlocked condition 100 301 to 1500 Note 1) Intermediate strokes other than the above are
NIL IDF 100 F 30 4 W C 5 G Size K Size Air compressor size Note) 100kW 125kW 150kW 100 125 150 P R Note) The value is referential. Confirm the capability of the compressor used.
180 210.5 226 250 135 140 155 134 146 162.5 20 24 24 VNC5-32F VNC6-40F VNC7-50F 100 105 120 36 42 54 12 12 14 310.5 326 350 278 293.5 317.5 VX Port size: 65F, 80F Flange connection VN VQ Applicable flange 65 80 Model H F E D C B A 1 4 1 4 405.5 441.5 65 80 140 150 204 235 175 185 305.5 341.5 210 240 VNC81 -65F VNC91 -80F 4.2-25 VNC Construction N.C.
25, 32, 40, 50, 63 Sine Rodless Cylinder Series 12-REA How to Order Clean series 12 Special treatment on sliding part Bore size (mm) 12 R E A 25 300 Cylinder stroke (mm) Type Port type Symbol Nil TN TF Rc NPT G Model Bore size (mm) Maximum manufacturable stroke (mm) Model Port size Lubrication Standard stroke (mm) 12-REA25 12-REA32 25 32 40 Rc1/8 NPT1/8 G1/8 Rc1/4 NPT1/4 G1/4 200, 250, 300
air supply Pressure in the tank New New 20 9.2 4 AV2000-A Current model 30 13.1 7.4 Up to 50% shorter 40 19.2 12.2 50 (Port size 3/4) 34.8 22.6 AV2000-A New New Fill time 50 (Port size 1") 41.3 24.4 Current model For 1(P) R 2(A) Improved adjustability at low speed air supply Needle Valve Flow Rate Characteristics Inlet pressure: 0.5 MPa 400 Air flow rate [L/min (ANR)] 350 Current model 300
Series 12-REA Sine rodless cylinder 25, 32, 40, 50, 63 How to Order Clean series 12 Special treatment on sliding part Bore size (mm) 12 REA 25 300 Cylinder stroke (mm) Type Port type Symbol Nil TN TF Rc NPT G Model Bore size (mm) Maximum manufacturable stroke (mm) Model Port size Standard stroke (mm) Lubrication Rc1/8 NPT1/8 G1/8 Rc1/4 NPT1/4 G1/4 12-REA25 12-REA32 25 32 40 200, 250, 300
operated poppet valve Air/Inert gas 0.7 MPa 0 MPa/101.2 kPa ON: 4 ms 1, OFF: 2 ms 1 10 to 50C Note 2) Valve specifications Electrical specification Minimum operating pressure / Vacuum Response time Note 1) L plug connector Base mounted L plug connector Body ported Ambient and fluid temperature Lubrication Manual override Impact / Vibration resistance Note 3) Not required Non-locking push type 150
Set range is 0 to 300 sec. to Contact input signal 2 OFF detection timer Setting and checking 43. Press the [SEL] key once. The set screen of contact input signal 2 OFF detection timer is displayed on the digital display. PV SV 44. Select contact input signal 2 OFF detection timer from the table below with [] key or [] key, and confirm by pressing SEL.
Set range is 0 to 300 sec. to Contact input signal 2 OFF detection timer Setting and checking 43. Press the [SEL] key once. The set screen of contact input signal 2 OFF detection timer is displayed on the digital display. PV SV 44. Select contact input signal 2 OFF detection timer from the table below with [] key or [] key, and confirm by pressing SEL.
Setting of the contact input signal 1 delay timer of reading Setting range: 0 to 300 seconds to Setting/Checking: Contact input signal 1 OFF detection timer 35. Press the [SEL] key once. Setting screen of contact input signal 1 OFF detection timer is displayed on the digital display. PV SV 36.
Specifications SL5201mmA Operating Parameters SL5201 0.5 to 10 psig (0.0034 to 0.07 MPa) SL5202 0.5 to 30 psig (0.0034 to 0.2 MPa) SL5206 1 to 60 psig (0.007 to 0.4 MPa) SL5210 1 to 100 psig (0.007 to 0.7 MPa) 100 mm Hg absolute to 10 psig (-88kPa to 0.07 MPa) Select compatible materials of construction for the gas Vacuum to 150 psig (1.0 MPa) 500 psig (3.4 MPa) 1000 psig (6.9 MPa) 40 to
VS Surge voltage suppressor mounting part VFN Surge voltage suppressor Electrical entry JIS Symbol G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire D DIN terminal E Grommet terminal T Conduit terminal Manifold Applicable manifold type Accessory Function plate (DXT152-14-1A) Note) Mounting screw (NXT013-3) Model VO307 Common or individual exhaust Note) It is not applied to Continuous
VH600 VR Option VH300 VH410 VH VH300/400 Bottom ported VH210 VHS VH200/300/400 Panel mounted All models applicable Different P port location (On handle side) Note that 1(P) port of VH600 is located on handle side as standard.
2.5 (N) E A (U) S Q D G C C B L1 L2 L3 16 D side U side Stations 1 2 3 4 5 n 21 5.5 16 OUT port n-1/4 n-1/8 H H P=J (pitch) 2 : Thread type L dimensions (mm) n (stations) Model Dimension 2 3 4 6 9 7 5 8 10 L1 69 103.5 138 207 310.5 241.5 172.5 276 345 VV2CL2 L2 81 115.5 150 219 322.5 253.5 184.5 288 357 L3 93 127.5 162 231 334.5 265.5 196.5 300 369 L1 77 115.5 154 231 346.5 269.5 192.5 308
/ When lubricated, use turbine oil #1(ISO VG32) VH600 Optional specifications VH300 Bottom porting VH410 VH300, 400 Panel mount VH200, 300, 400 VH210 Different P port location* All models 1(P) port is located on handle side.