Lateral 0.2 0.1 200 300 500 100 Load point distance mm LJ1H20 LJ1H30 20 10 Lateral load 100% 10 5000 Lateral load 50% 5000 2000 Horizontal load 100% 2000 Horizontal load 50% 1000 Horizontal load 100% 1000 Horizontal load 50% 500 500 Amount of deflection m Amount of deflection m 200 200 100 100 50 50 20 20 10 Lateral load 100% 10 5 Lateral load 50% 5 Horizontal empty weight deflection 2 2
40 80 50 50 20 20 Load mass m (kg) Load mass m (kg) Load mass m (kg) 20 10 10 10 63 63 63 5 5 5 50 50 50 [Example ] 40 40 40 1 1 1 70 100 300 500 1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.
Load voltage Lead wire length (m) Applicable load Perpendicular In-line Perpendicular In-line Direct mount Rail mount Indicator light Type Special function Wiring (output) Electrical entry DC AC 20 to 50 32 to 50 0.5 (Nil) 3 (L) 5 (Z) None (N) 3 wire (NPN equiv.)
to 63 50 to 63 Approx.
Remove the side panel and the plug 5 in the body, and open the stop valve 4. 4. Be sure to mount the plug 5 after draining the water, and close the stop valve 4 in the body. 5. Return the panel to the original position. 4. Stop valve in the body 5. Plug 4. Stop valve in the body Automatic fluid filling valve 5. Plug 2. 3.
Note 5) Value clear 0.01 psi in psi display.
Max. load current or load current range (mA) D-A53 None PLC 5 to 50 24VDC 5 to 50 24VDC 5 to 25 100VAC Relay, PLC D-A54 5 to 12.5 200VAC None D-A56 20 IC circuit 4 to 8VDC 50 24VAC/DC or less None D-A64 25 100VAC Relay, PLC 12.5 200VAC None 30 Max. 24VDC None IC circuit, PLC D-A67 (2 color indication) 5 to 40 Relay, PLC 24VDC D-A59W None PLC 5 to 50 D-A33 24VDC 5 to 50 24VDC D-A34
With (1) DIN connector DIN terminal without connector DIN connector DIN terminal without connector Without Coil voltage (1) With (1) 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC Others 1 2 3 4 5 6 9 With (w/o light) (1) YOS Note 1) DIN is applicable to VQZ2000, 3000.
W Fulcrum L Front matter 5 Series CKZ3 Model Selection Model Selection CKZ3N North American Type Made to Order European Type CKZ3T 3 Clamp arm 50 63 300 150 280 140 Distance from pivot point L(mm) Distance from pivot point L(mm) 260 130 240 120 220 110 200 100 180 90 160 80 140 70 120 60 100 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 50 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
23 55 53 28 M8 x 1.25 10 86 6.9 9.5 16 PA Bore size (mm) M MM (N) (NA) NN PB PW Q QW RB RW S T U W X Y Z 12 M4 x 0.7 M8 x 1.0 6 8 27 30 60 80 85 26 RB0806 17.5 96 13 1 77 22 7.5 5 16 M5 x 0.8 M8 x 1.0 8 8 27 45 70 95 90 40 RB0806 15 103 13 2 92 22 7.5 5 20 M6 x 1 M10 x 1.0 10 10 29 60 100 120 105 46 RB1007 26 122 17 2 117 29.5 9 5.5 25 M6 x 1 M14 x 1.5 10 12 50 60 100 130 105 50 RB1411
(Load current at 100 mA) Output signal Voltage output 1 to 5 V (Connect a 10 k or larger load.) 50 to 2000 mm (Sensing DC mode: 200 to 2000 mm) 0 to 50C 35 to 80% Rh (No condensation) Cover of ionizer: ABS, Emitter: Tungsten, Single crystal silicon, Stainless steel Durability 50 Hz Amplitude 1 mm XYZ each 2 hours 10 G Effective distance of static neutralization Ambient temperature, Fluid
(n 2) 2 D-C7 D-C80 D-H7C D-C73C D-C80C D-G5/K59 D-G5W/K59W D-G59F/G5BA/G5NT D-B5/B64 50 + 45 (n 2) (n = 2, 3, 4, 5) 10 15 50 D(n = 2, 4, 6) Note 3) 15 + 50 (n 2) 2 65 + 50 (n 2) (n = 2, 3, 4, 5) 10 15 65 15 + 50 (n 2) 2 75 + 55 (n 2) (n = 2, 3, 4, 5) 10 15 75 (n = 2, 4, 6) Note 3) (n = 2, 4, 6) Note 3) 20 + 50 (n 2) 2 75 + 55 (n 2) (n = 2, 3, 4, 5) D-B59W 15 20 Note 3) When n is
Shock absorber specifications cannot be changed by replacing or adding parts. 50 to 500 80 245 80 245 10 to 60 1.96 3.83 15 1.96 4.22 15 Spring force N Extended Compressed Weight g Minimum Strokes for Auto Switch Mounting (mm) Applicable auto switch models Number of auto switches mounted 1 pc. 2 pcs. 5 10 5 10 5 5 D-A9, D-A9V D-F9, D-F9V D-F9W, D-F9WV D-F9BA 2 Series MXP Table Deflection
Auto switches / Proper mounting position for stroke end detection Electrical entry direction: Inward Electrical entry direction: Outward B D C A (mm) D-Z73 D-Y59A,D-Y59B A B C D Bore size D 0.5 4 0.5 3 5 5 C 16.5 23 34 46 46.5 56 6 20.5 27 38 50 50.5 60 -1 2.5 -1 1.5 3.5 3.5 32 15 21.5 32.5 44.5 45 54.5 4.5 8 4.5 7 8.5 9 10 15 20 25 Note 1) The above mentioned values are indicated as a guide
mm 0.01 mm 0 0 0 50 100 150 200 250 0 50 100 150 200 250 Supply pressure (kPa) Supply pressure (kPa) Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 2.0 Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 2.0 0.6 0.4 0.5 mm 0.25 mm 0.5 Detection distance (mm) Detection distance (mm) 0.3 0.4 0.3 0.2 0.15 mm 0.2 0.15 mm 0.1 0.1 0.03 mm 0.01 mm 0 0 0 50 100 150 200 250 0 50
0 10 20 30 40 50 60 0 10 20 30 40 50 F F Gripping point L mm Gripping point L mm MRHQ16D MRHQ16D Pressure 0.7MPa External gripping 60 50 0.6MPa 50 Pressure 0.7MPa Gripping force N Gripping force N 0.5MPa 40 0.4MPa 0.5MPa 0.6MPa 40 0.4MPa 30 30 0.3MPa 0.3MPa 20 20 0.2MPa 0.2MPa 10 10 L L 0 10 20 30 40 50 60 0 10 20 30 40 50 60 Gripping point L mm Gripping point L mm MRHQ20D MRHQ20D Internal
100 100 150 150 200 200 1500 0 150 300 450 600 750 900 1050 1200 1350 1500 0 150 300 450 600 750 900 1050 1200 1350 Distance [mm] Distance [mm] 5) Supply pressure: 0.4 MPa Flow rate consumption: 316 L/min (ANR) 6) Supply pressure: 0.5 MPa Flow rate consumption: 390 L/min (ANR) 200 200 2 s 150 150 1.5 s 100 100 50 50 0.5 s 1 s 1.5 s 0.5 s 1 s 50 50 100 100 150 150 200 200 1500 0 150 300 450
5% ON OFF [F 2] OUT2 36 ON OFF 50% 5% OUT1 ON OFF 50 5 -26No.PF-OMM0004-D / [F3] 42 1 [F10] 43 [F20] 47 [F22] 48 OFF [F30] 50 OFF[] [F80] 51 [] [F81] 52 OFF [F82] 53 [*] [F90] 54 OFF [F98] 55 OFF [F99] 56 OFF 30 [F10](43 ) (4 L/min ) OUT2 -27No.PF-OMM0004-D [F 1] OUT1 OUT1 1.