C J G5-S 150 cm3/min or less 200 cm3/min or less 300 cm3/min or less Supply pressure 0.1 MPa Total allowable leakage 800 cm3/min or less 1000 cm3/min or less 1200 cm3/min or less Weight/Standard Type: MQQT Supply pressure 0.3 MPa CV 1500 cm3/min or less 2000 cm3/min or less 3000 cm3/min or less Supply pressure 0.5 MPa (g) Note 1) Use clean, dry air with no freezing.
AMD AMH Data A: Inlet Air Temperature Data B: Ambient Temperature Data C: Inlet Air Pressure AME Inlet air temperature Ambient temperature Inlet air pressure MPa psi Correction factor F C Correction factor AMF Correction factor IDFB3E to 37E IDFB55E, 75E 1.31 F C 77 90 95 100 104 25 32 35 37.8 40 75 100 110 120 125 150 175 200 232 0.53 0.70 0.76 0.83 0.86 1.03 1.21 1.38 1.60 1.24 0.95 ZFC
Table 4-1 EX245 24 V DC +20% -15% 1ms IP65 () (IEC60529) 10M -FE 500VAC IEC61131-2 500VAC1 -FE IEC61131-2 -10 to 50 -20 to 60 35%85% RH 80 kPa 108 kPa ( 2000 m ) 66 kPa 108 kPa ( 3500 m ) 10 Hz to 57 Hz 0.75 mm 57 Hz to 150 Hz 49 m/s 2 XYZ 2 XYZ 3 EN 60068-2-27/29 EMC , 2014/30/EU, IEC61326-3-1 , 2006/42/EC, EN 62061, EN ISO 13849 TUV , EN 61508, EN 62061, EN ISO 13849
Piston speed (3) 150 cm3/min or less 200 cm3/min or less 300 cm3/min or less Supply pressure 0.1 MPa Total allowable leakage MQQ M 800 cm3/min or less 1000 cm3/min or less 1200 cm3/min or less Supply pressure 0.3 MPa 1500 cm3/min or less 2000 cm3/min or less 3000 cm3/min or less Supply pressure 0.5 MPa RHC Note 1) Use clean, dry air with no freezing.
Micromist separator AMD900, 1000, 901 Model Connect (Flange) 2B 6B C 2B/3B/4B 400 A 280 B 760 D 150 E 270 F 1033 G 3 H 887 J 620 AMD801 AMD901 12B 445 795 300 520 1318 3 972 AMD800/900/1000 ORIENTATION Mounting Caution q Verify the direction of the flow of the compressed air and the "e" mark that indicates the inlet of the product before connecting.
AMF150 AMF250 AMF350 AMF450 AMF550 AMF650 AMF850 Rated flow (l/min (ANR))(1) 200 500 1000 2000 3500 6000 12000 Port size (Nominal size B) 1/8, 1/4, 3/8 1/4, 3/8, 1/2 3/8, 1/2, 3/4 1/2, 3/4, 1 1, 11/2 11/2, 2 3/4, 1 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note 1) Max. flow capacity at a pressure of 0.7MPa.
160.5 5 113 130.5 150 160.5 6 124.5 142 162.5 173 7 136 153.5 175 185.5 8 147.5 165 187.5 198 9 159 176.5 200 210.5 10 170.5 188 212.5 223 11 182 199.5 225 235.5 12 193.5 211 237.5 248 13 205 222.5 250 260.5 14 216.5 234 262.5 273 15 228 245.5 275 285.5 16 239.5 257 287.5 298 L1 L2 L3 L4 21 5 Port Solenoid Valve Series SQ1000/2000 SQ2000/Flat Cable Kit Stations SS5Q23JD0 L2 L3 L4 5.25 Indicator
Station n L1 L2 L3 L4 Station 20 341 328 304 296 3 69 56 32 24 6 117 104 80 72 8 149 136 112 104 10 181 168 144 136 Station 2 53 40 16 8 4 85 72 48 40 5 101 88 64 56 7 133 120 96 88 9 165 152 128 120 11 197 184 160 152 12 213 200 176 168 13 229 216 192 184 14 245 232 208 200 15 261 248 224 216 16 277 264 240 232 17 293 280 256 248 18 309 296 272 264 19 325 312 288 280 4-4-27 Series SYJ500
Refrigerant R407C (HFC) Series IDF100FS/125FS/150FS Applicable Compressor Size: 100 kW, 125 kW, 150 kW (Max. inlet air temperature: 140F (60C) (Max. ambient temperature: 113F (45C) RoHS How to Order IDF 30 100 FS Nil C K P R V Nil 1 2 3 Size Size Air compressor size Note) 100 100 kW 125 125 kW 150 150 kW Note) Note that the above values are for reference only.
Display LCD LCD with backlight LED Pressure setting range 101 to 10 kPa 101 to 0 kPa Maximum operating pressure 200 KPa Operation indicator light (Lights up when ON) Green OUT1: Green OUT2: Red Response frequency 200 Hz (5 ms) Hysteresis mode Variable (3 digits or more) Variable (can be set from 0) Hysteresis Window comparator mode Fixed (3 digits) Fluid Air, Non-corrosive gas Temperature
mm Height: 5.91 in / 150 mm , Length: 8.07 in / 205 mm, Width: 5.98 in / 152 mm, Height: 5.91 in / 150 mm, Net Weight: 14.33 lbs. / 6.5 Kg Series Configured Datasheet.
CD-P11 CD-P12 Load voltage 24 VDC 100 VAC or less 200 VAC Note) Hysteresis may fluctuate due to the operating environment. Please contact SMC if hysteresis causes an operational problem.
Suitable 20 for m and 0.7 for . 1000 ML2B 6 10 15 20 25 30 40 50 63 80 100 125 140 160 180 200 250 300 0.057 0.099 0.113 0.120 0.184 200 300 400 500 E1 4.9 J In the case of cylinder stroke at load and free horizontal impact, 0.157 0.274 0.314 0.334 0.511 C J G5-S E1 or E substitute respective figures for Data A in order to calculate E1. 100 Impact object weight m or corresponding weight
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.1 0.05 0.01 50 100 300 200 (141) 500 Maximum speed (mm/s) 2. Rod end allowable lateral load Make sure that the lateral load that is applied to the rod end will be no more than the values shown in the tables.
type) Displacement m Displacement m 200 200 150 150 130 120 50 50 MSZA30A (High precision type) MSZA50A(High precision type) D70 60 50 40 30 20 10 0 120 100 80 60 40 20 0 Load N Load N 291 Rotary Table Air Consumption Air consumption is the volume of air which is expended by the rotary tables reciprocal operation inside the actuator and in the piping between the actuator and the switching
0 CG1YB20 -200 Example Smooth cylinder combined with precision regulator (e.g.
3 Port Solenoid Valve Base Mounted Type VQ100 Series Compact Design With Large Flow Rate High Speed Coil (ON: 3.5 ms) Long Service Life (200 million cycles) Innovative Manifold Construction Table of Contents Product Features .5 Specifications .6 How to Order .7-9 Plug-in Non plug-in Dimensional Drawings .10-14 Plug-in Non plug-in Construction .14 Operation Guide .15-18 The Preferred
Bore size/Stroke (mm) 10 25, 50, 75, 100 Cushion (Option) 15 25, 50, 75, 100, 125, 150, 175, 200 With adjusting bolt (2 pcs.) Nil 25 25, 50, 75, 100, 125, 150, 175, 200 B With shock absorber (2 pcs.) For 15 and 25, strokes up to 300 are available as made-to-order. (-XB11) BS With shock absorber (1 pc.)
0 to 60 0 to 250 20 to 150 X X X X The above table covers only general characteristics of subject rubber materials.
100/200 100/200 100/200 100/200 100/200 100/200 100/200 100/200 100/200 ** Non-Standard Product, consult factory for lead time.