12.5 3 15 20 Angle adjustment screw 32 15 17.5 20 4 25 30 30 12.5 15 (mm) 3 L Max. 32 Max. 31.5 Size 32 40 20 15 40 Possible to Change the Specifications from the Basic Style to -X5 17.5 20 4 25 Specify the part number for hexagon socket head cap screw for angle adjustment referring to the list below. 30 30 Size 32 40 Part no.
) 50 (63) 5 3 1 32 (42) 38 (53) 1 23 (30) 2-Rc3/8, 1/2, 3/4 Ports R1, R2 Rc1/8 Port X (PE) 30 (42) 30 (42) 2-Rc3/8, 1/2, 3/4 Ports R1, R2 Rc3/8, 1/2, 3/4 Port P Rc1/8 Port X (PE) 30 (42) 30 (42) Rc3/8, 1/2, 3/4 Port P Dimensions inside ( ) are for Rc3/4 Dimensions inside are for rubber seals Dimensions inside ( ) are for Rc3/4 19 Series VQ7-8 Prewired Connector Type 2 position/Single : VQ7
(assuming approximately 30% dispersion.)
(mm) (mm) 5 20 25 30 10 15 Stroke 50 40 75 100 Y 15 15 20 20 25 12.5 12.5 17.5 15 30 Q 30 20 20 20 73.5 E 66 71 63.5 63.5 63.5 58.5 61 61 61 MRQFS32SMRQ32, #3 (Flange only) 1.5-13 Series MRQ Size40 Basic Style/MRQBS40 The dimensions below shows an actuator with a rotation angle of 80 to 100 style.
142 63 M10 x 1.5 9 M10 x 1.5 WA WB Bore size (mm) VB X XA XB XC XL YY YL Z st25 25
Air dryer model IDF100FS-30-R IDF125FS-30-R IDF150FS-30-R Breaker capacity 20 A 30 A Sensitivity current: 30 mA Corrosion is not covered under warranty. Option symbol V With a timer controlled solenoid valve type auto drain Option symbol Float type heavy duty auto drain is changed to the solenoid valve type auto drain.
/301 Pulse output (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V) Output Voltage output Note 5) 1 to 5 V Analog Linearity: 2% F.S. or less, allowable load resistance: 100 k or more specifications output Current output Note 6) 4 to 20 mA Linearity: 2% F.S.or less, allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC Power supply voltage
Ratio of resistance [k m] 100 10 50 Particle ratio [number/cc] 1 0 5 10 15 20 25 30 Duration of flow [min] 2 or 3 particles/cc Tube 00 10 20 30 40 50 60 70 Duration of flow [min] The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16Mcm of deionized water at class 10 clean room (1l/min flow rate).
-4A-6 1 2) / 1) 2) 300 4 DC24V 6 600 10 1000 15 1500 20 2000 25 2500 30 3000 50 5000 ZL3/ZL6 SY100-30-A *x2 17 No.ZL3-OM00801-A ZL3/ZL6 ZS-39-5G ZL3-LW1-N-A 1 1) N NPN P PNP 2 ZL3/ZL6 ZL3-EJ1-H-A 1 2) 1) M 0.35 MPa H 0.50 MPa 4 M4x110 2)1 :0.760.84Nm V * 1 3 ZL3 ZL3-SC1-A 4 ZL3 ZL3-SE1-A 1 2 18 No.ZL3-OM00801-A 5 ZL6 ZL6-SC1-A () * 6 ZL3/ZL6 ZL3-EP1-1 -A 1 1
Standard Strokes Bore size [mm] Standard stroke [mm] 12, 16 5, 10, 15, 20, 25, 30 20, 25, 32, 40 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 50, 63, 80, 100 10, 15, 20, 25, 30, 35, 40, 45, 50 Intermediate strokes are available as a special order.
Lead wire length Nil 6 10 15 20 25 30 300 mm (Standard) 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm How to order When requiring a vacuum unit equipped with valves with lead wires of 600 mm or more, specify the vacuum module valves without the standard connectors and order the required connector ass'ys separately. Example) ZR120S1-K15MZ-EC . 1 pc.
Standard Strokes Symbol Rubber bumper Bore size [mm] Standard stroke [mm] 12 (10 x 2) 16 (12 x 2) 10, 20, 30, 50, 100 20 (16 x 2) 25 (20 x 2) 20, 30, 50, 100, 150 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) 25, 50, 100, 150, 200 Intermediate strokes are available as a special order. Refer to pages 10 and 11 for cylinders with auto switches.
The right side of the common port provides plug. 4.1-55 VVX31/32/33 Dimensions Model Station Symbol 2 96 84 126 108 3 132 120 172 154 4 168 156 218 200 5 204 192 264 246 6 240 228 310 292 7 276 264 356 338 8 312 300 402 384 9 348 336 448 430 10 384 372 494 476 L1 L2 L1 L2 VVX31 VVX32 VVX33 Model VVX31 VVX32 VVX33 A 40 44 44 B 20 22 22 C 9 10 10 D 22 24 24 F 33 34 34 H 24 25 25 J 30 40 40
0.5MPa 0.5MPa Gripping force N Gripping force N 0.4MPa 0.4MPa 150 150 F 0.3MPa 0.3MPa 100 100 0.2MPa 0.2MPa 50 50 0.1MPa 0.1MPa 0 0 10 10 20 20 30 30 40 40 50 50 Gripping point L mm Gripping point L mm MHS2-50D MHS2-50D F 400 400 Internal gripping Pressure 0.6MPa Pressure 0.6MPa 300 300 Gripping force N 0.5MPa 0.5MPa Gripping force N 0.4MPa 0.4MPa 200 200 0.3MPa 0.3MPa 1N: Approx. 0.102kgf
36.9 43.9 47.3 JC 43 39 36 32 NA 26 32 38 41 I 26 31 38 47 H 44 48 51 54.5 N 22 27 27 30 WH ZZ 252 257 265 277 5.8 to 8.8 6.8 to 11.3 4.10-9 Series RHC Construction u q !
Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% 1 Electric spec.
Copper extension nozzle/KNL (mm) Model Nozzle size D Outside diameter L1 Weight (g) KNL3-06-150 KNL3-06-200 KNL3-08-200 KNL3-08-250 KNL3-10-250 KNL3-10-300 KNL6-06-150 KNL6-06-200 KNL6-08-200 KNL6-08-250 KNL6-10-250 KNL6-10-300 1.5 2 2 2.5 2.5 3 1.5 2 2 2.5 2.5 3 6 6 8 8 10 10 6 6 8 8 10 10 300 300 300 300 300 300 600 600 600 600 600 600 43 43 61 61 94 94 84 84 117 117 183 183 O.D.
IN side, OUT side 4 10 22 20 22 30 30 50 30 75 39 75 39 Series ZFB Model ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 6 6 8 8 10 Metric size 3/16" 20 22 20 22 30 30 75 40 100 62 ZFB101-05 ZFB101-07 ZFB201-07 ZFB301-11 ZFB401-13 1/4" 1/4" Inch size (2) 3/8" 1/2" Specifications Fluid Air/Nitrogen Negative pressure 0.5MPa 0 to 60C (Non-freezing) 30m 0.15MPa Nylon/Soft Nylon/Polyurethane
Changes from the standard type are: KT10F KT10H KT10R KT10J KT10L KT10N KT10P Option Other Parameters HF Source pressure Cv 6000 psig (41.4 MPa) 0.12 Wetted Parts Material S B 316 SS 316 SS Brass Bronze 300 SS series Vespel (Option: PEEK) PCTFE Viton (Option: Polyurethane, Buna-N, Ethylene propylene) PTFE C 300 SS series 316 SS Wetted Parts Body Inlet filter Piston and trim Seat, main valve
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) When equipped with DC solenoid/surge voltage suppressor, a delay of about 20 to 30 m/sec. occurs in the OFF response time.