Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: B (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5), 1st
Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5), 1st Selection Supply Valve
Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 2 (ø1.0), 1st Selection Supply
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Speed Controller with Uni One-touch Fitting AS Series How to Order 2 2 1 U02 06 AS 1F Hexagon lock nut Round lock nut J Nil Lock nut option Body size AS-F AS-F 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard Made to Order TMH X260 Antistatic type Refer to page 635 for details. ASD None Electroless nickel plated N Nil Option AS Type Elbow Universal 2 3 AS-FE Applicable tubing O.D.
Valve: None; Stop Valve: None, Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
S) D H VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 VXA VN A port LVC 2-G LVA LVH SMC LVD SMC (J) C LVQ LQ E LVN TI/ TIL PA F K B port E PAX PB A B C D E F G H J K S LVN20 LVN30 LVN40 Model 48 60 72 2.4 7.5 8.0 18 24 30 20 26 33 14 25 25 4 5 6 6 9 11 34.5
/analog output 3 rotations, PNP output T54 Rated voltage Standard supply pressure 5 24VDC 0.5MPa 0.35MPa 0.45MPa H M S Valve K Air supply valve/Vacuum release valve Thread type Nil T F Rc NPTF G How to Order Ejector Manifolds ZZMA 06 06 R Mixed mounting is possible with vacuum ejector series ZM.
How to Order Manifold Example/Valve T C VV3QZ15 08 N7 VQZ215R 5M 02 Thread (Cylinder ports and P, R ports) External pilot specification Example/Manifold VV3QZ25 Rc(PT) 06C6C R N NPT T NPTF F G(PF) External pilot specification Cylinder ports (1) Symbol N1 N3 N7 N9 N11 NM M5 01 02 External pilot port 3/8" 1/8" 5/32" 1/4" 5/16" Mix M5 1/8 Tube O.D.
Thread type Common EXH port size 04 1/2 Nil T F Rc NPTF G 06 3/4 S Silencer dedicated for ZZMA (ZZM-SA) Indicate the ejector model no. below the manifold base no. Example) Manifold model no.: ZZMA04-SR (1 pc.)
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)