AW-OMX0057-A PRODUCT NAME Filter Regulator MODEL / Series / Product Number AW20(K)-(F,N)01(F,N)02(B,C,E,E1,E2,E3,E4,G,H,M)(-1,2,6,C,J,N,R,Z,ZA)-D AW30(K)-(F,N)02(F,N)03(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AW40(K)-(F,N)02(F,N)04(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AW40(K)-(F,N)06(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AW60(K)-(F,N)06(F,N)10(B,C,

Note 2) Cable (7) external: 6 to 8 mm y t r e How to Calculate the Flow Rate 3.

AC 110 12 2 12 3 q e w e t y 220 10 1 10 1.5 440 6 1 3 1 550 5 0.8 2 0.5 r b contact w a contact r q DC 24 3 2.5 3 2.5 C C 48 1.5 1.2 1.5 1.25 When rising pressure q w = ON e r = OFF When rising pressure q e r y = ON q w r t = OFF 110 0.5 0.25 0.5 0.2 220 0.25 0.1 0.25 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 2000 VAC/1 min. 16-9-5 Series

Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with a switching element or when a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the leakage voltage passing through the C-R circuit. The suppressor residual leakage voltage should be as follows. 4.

2 IN OUT IN OUT u r t i u r t i Component Parts Material AWG20K AWG30K AWG40K Note No. Description Body 1 ZDC ADC Platinum silver Bonnet 2 PBT Black Handle 3 POM Black Replacement Parts Part no. AWG20K No.

AW-OMZ0061 PRODUCT NAME Mist Separator Regulator MODEL / Series / Product Number AWM20-(F,N)01(F,N)02(B,C,E,E1,E2,E3,E4,G,H,M)(-1,2,6,C,J,N,R,Z,ZA)-D AWM30-(F,N)02(F,N)03(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AWM40-(F,N)02(F,N)04(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D Contents Page 1. Safety Instructions 2-8 2. Application 9 3. Standard Specifications 9 4.

AW-OMZ0062 PRODUCT NAME icro Mist Separator Regulator MODEL / Series / Product Number AWD20-(F,N)01(F,N)02(B,C,E,E1,E2,E3,E4,G,H,M)(-1,2,6,C,J,N,R,Z,ZA)-D AWD30-(F,N)02(F,N)03(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AWD40-(F,N)02(F,N)04(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D Contents Page 1. Safety Instructions 2-8 2. Application 9 3.

If not, insert a R 1/8 plug. Note 2) In the case of external pilot, supply air pressure from X port.

Auto switch types D-A3, D-A44 D-G39, D-K39 D-A5, D-A6, D-A59W, D-F5, D-J5 D-F5W, D-J59W, D-F5NT, D-F5BA, D-F5F D-B5, D-B6 Bore size (mm) 40 50 63 80 100 BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M BA-04 BA-05 BA-08 BA-10 BT-04 BT-06 BT-06 BT-08 BT-08 Standard Strokes Standard strokes (mm) Bore size (mm) 40 50 63 80 100 125 160 25 to 800 25 to 800 25 to 800 25 to 1000 25 to 1000 25 to 1000 50

6 @2 r y w t e t @2 u i !0 @0 !5 y !9 ZL6 Without valve or pressure switch, Silencer exhaust ZL6 With valve and pressure switch, Port exhaust @1 !2 !3 !1 !6 !8 !7 q !4 r y w t e t u i @0 !5 y !9 Component Parts No. Description Material Note No.

R and S (Because S function is also included in R.) S and T (Because S function is also included in T.) Note 2) Voltage symbol 20 (200 VAC) is the terminal block connection as standard. Option S cannot be chosen. Voltage symbol 10 (100 VAC) is the power cable with plug as standard.

VX B 1 2 1 2 VX3 A VXA B NL R VN R LED B NL: Neon light R: Resistor LED: Light emitting diode R: Resistor LVC Caution LVA Valve Mounting After confirming the gasket is correctly placed under the valve, tighten the mounting screws with the appropriate torque (0.2 to 0.23 Nm).

IDFA6E-20 12 2 12-3 Installation of heavy duty auto drain IDX-OM-W089 Air Dryer 13 Specification for Option R 13 Specification for Option R Option R installs a Ground Fault Circuit Interrupter (GFCI), it will shut off the power supply in case the product should have over current or current leakage.

Applicable pilot valve (4) 00 M5 00 M5 01 00 01 02 00 02 03 04 M5 01 02 02 03 04 04 06 10 10 12 14 20 Without sub-plate M5 Without sub-plate M5 D B 1 8 Without sub-plate Base mounted Symbol 2 1 8 1 4 Internal pilot VY1D0 (5) Without sub-plate 1 4 4 3 8 1 2 (3) (3) A M5 3(R) 1 8 2(A) 1(P) (3) (3) 1 1 4 1 4 3 8 3 External pilot 1 2 Body ported 1 2 5 3 4 P1 1 1 VY1B0 (5) 7 1 1 4 1 4 1 1 2 1

INP = 1 indicates that the target location has been reached. 12 Repeat steps 9-10 After settling time, the operation of step data No.20 is 13 completed. 14 01 10 9103 0002 04 0 2710 01 10 9103 0002 Step Data No. 20 target position changed to 10 mm.

Model symbol (In-line filters) Element size 125mm 65 x 250mm Bore size 04 06 Rc 1/2 Rc 3/4 2.

AR-OMT0015 PRODUCT NAME REGULATOR MODEL/ Series AR20K-(F,N)01 (F,N)02(B,E,G,H,M)(-1,N,R,Y,Z)-B AR25K-(F,N)02 (F,N)03(B,E,G,H,M)(-1,N,R,Y,Z)-B AR30K-(F,N)02 (F,N)03(B,E,G,H,M)(-1,N,R,Y,Z)-B AR40K-(F,N)02 (F,N)04(B,E,G,H,M)(-1,N,R,Y,Z)-B AR40K-(F,N)06(B,E,G,H,M)(-1,N,R,Y,Z)-B AR50K-(F,N)06 (F,N)10(B,E,G,M)(-1,N,R,Y,Z)-B AR60K-(F,N)10(B,E,G,M)(-1,N,R,Y,Z)-B Contents PAGE 1.

BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon receipt of order.

R: Right (OUT side) L: Left (IN side) -X L R 20Made to Order Specifications (For details, refer to page 8-31-1.) Theoretical Output Dual rod cylinder produces double the thrust of standard cylinder.