Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: DC12V, Specification: Standard / Lubrication Free / Low Current, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Open, Pipe Port Type: -, Port Size: -, Pressure Rating(MPa): 0.2 to 0.7,

Series: VP500, Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 12VDC, Electrical Entry: Grommet, 300mm Lead Wire Length, Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: w/o Sub-plate, Thread Type: Rc, Actuation Type: N.O., Normally Open, Made to Order: -

Series: VP700, Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 12VDC, Electrical Entry: Grommet, 300mm Lead Wire Length, Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: w/o Sub-plate, Thread Type: Rc, Actuation Type: N.O., Normally Open, Made to Order: -

Series: 344 (VP300), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 6 (12VDC), Electrical Entry: G (Grommet, 300mm Lead Wire Length), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: w/o Sub-plate, Thread Type: Rc, Actuation Type: B (N.O., Normally Open)

Series: 544 (VP500), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 6 (12VDC), Electrical Entry: G (Grommet, 300mm Lead Wire Length), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: w/o Sub-plate, Thread Type: Rc, Actuation Type: B (N.O., Normally Open)

Series: 744 (VP700), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 6 (12VDC), Electrical Entry: G (Grommet, 300mm Lead Wire Length), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: w/o Sub-plate, Thread Type: Rc, Actuation Type: B (N.O., Normally Open)

Fittings & Tubing Air Cylinders Rotary Actuators 0 L0.1 4 x MM Thread depth J 2 x P (Piping port) A G E H G B NN Effective thread length T (R) D X Mounting nut Width across flats C F N ZZ + Stroke S + Stroke W K N F I NA TT 6 T Model MM L K J I H G F E D C B A S NN NA 34 N R 12-REA25 12-REA32 12-REA40 8 46 32 26.4 2 13 7.5 20.5 8 10 70 15 M5 x 0.8 18.5 30 M26 x 1.5 111 10 8 60 32 33.6 2 16

Model Elbow type Straight type In-line type 12-REA25 10-AS2001F-06-X214 10-AS2201F-01-06-X214 10-AS2301F-01-06-X214 12-REA32 10-AS2001F-06-X214 10-AS2201F-02-06-X214 10-AS2301F-02-06-X214 6. Do not use the cylinder with its body fixed. Be sure to secure both head covers (or end covers in case of CY1R) before using the cylinder.

8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4

When the I/alues 01 P1 and P2 are equal 0<" when Pi > P2 but Wlthm 2 digits. the hystereSIs Will be au1omatll~ally set 102 digits for lhe sell/alue 01 PI An error code is displayed when overcurrent, excessive pressure, data error, or pressure during O-clear occurs.

Description Body A Handle Body B Needle Seat ring Needle guide Material Note No.

Controlled flow 0.25 0.3 0.3 0.25 0.25 0.25 0.25 * C and b values are for controlled flow with the needle fully open and free flow with the needle fully closed.

L 46 (24) Double pipe nozzle AIR OIL D C B 12 E A 24 9.5 2 3 57(Max.) 12.5 AIR SMC 27.5 4 10 40 23.5 OIL L Dimension (mm) 20 200 25 250 30 300 35 350 7.5 2 x 4.5 20 4 Symbol Length 17 T0425 (4 x 2.5) Applicable tubing T0604 (6 x 4) Applicable tubing Cross section ABCDE Main Parts List Description Material Aluminum die-casted No.

. : Standard wiring of the manifold is for double-solenoid valves and the output number starts at the A side and then B side in that order as shown in the figure a.

-10AS G46-2-02 G36-2-01 G46-2-02 G46-2-02 G46-2-02 0.2MPa Note 3) GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS Note 1) Assembly includes a bracket and set nuts.

1.0MPa Note 3) GC3-10AS Note 2) GC3-10AS GC3-10AS 1 4 1 8 1 4 Note 1) Pressure gauge G46-2-02 G36-2-01 G46-2-02 Set pressure + 0.05MPa (at relief flow rate of 0.1l/min(ANR)) 5 to 60C (With no condensation) 5m 0.2MPa Note 3) GC3-2AS GC3-2AS GC3-2AS Note 4) AD48 N.O.

Orange Calculation of Connected Plug and Socket Dimension Overall length of connected plug and socket B = Plug (L1 L2) + Socket (L2) + 0.5 Plug Socket Example) Overall length of KK3P-01MS (plug) and KK3S-01MS (socket) when they are connected.

B Locking ' Special Order option t Consult factory for availability NVF 1100-ODO{IT (drx ) Lamp and Sorga Protec-tion Z rv/Lamp/Surge Protection S dsurqe Protection Onlv L.mp and S dsurge Only BRACKET (Sutfix "F') .[ otMEr{stoNs A B c D E F 1.35 (34.41 1.34 (34.11 0.61 115.4) 0.83 Q 1 t 1.76 1.77 (44.9) Millamte.s in Parenthe$s rxfENsroNs A B c D E F G H J K It N o P o R 64.7) 0.83 (21) l.t

Set t i ng at t he t i m e of shi pm ent i s 01. 6 4 6 4 5 5 Set t i ng t he t erm i nat or Set PRO FI BU S com m uni cat i on l i ne t erm i nat or.