It may also result in non-conformity to safety standards. Product handling Installation Do not drop, hit or apply excessive shock to the fieldbus system. Otherwise damage to the product can result, causing malfunction. Tighten to the specified tightening torque. If the tightening torque is exceeded the mounting screws may be broken.

Carbon powder which adheres to the inside of the valves may cause malfunction. (4) Grease is applied to the inner parts of the valve. Grease may enter on the downstream side of the valve.

Splash zone Installable Food zone Food may directly contact with air grippers, and is treated as food products. Splash zone Food may directly contact with air grippers, but is not treated as food products. Non-food zone Air grippers do not directly contact food.

If mounted in the wrong direction, the speed adjustment needle may not function and may cause uncontrolled extension of the piston rod. rAdjust needle by opening the needle slowly after having closed it completely. Loose needle valves may cause unexpected sudden actuator extension. When needle valve is turned clockwise, it is closed and cylinder speed decreases.

Using excessive torque may cause damage to the body.

If any of the following practices are applicable, the valve may have some trouble inside.

Please consult with SMC for details, as delivery times may be extended.

Use of metal fittings Do not use metal fittings for piping on taper threads made of resin, as this may cause damage to the threads. 3.

The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 1.

Otherwise, the Card Motor may make an unexpected movement, leading to damage.

The pressure may not reach 0.1MPa when the air compressor discharge flow rate is small. Dehumidified drain may flow into the secondary piping if there is a sudden change of pressure or flow speed. Do not use the product where these conditions are present.

The pressure may not reach 0.1MPa when the air compressor discharge flow rate is small. Dehumidified drain may flow into the secondary piping if there is a sudden change of pressure or flow speed. Do not use the product where these conditions are present.

The pressure may not reach 0.1MPa when the air compressor discharge flow rate is small. Dehumidified drain may flow into the secondary piping if there is a sudden change of pressure or flow speed. Do not use the product where these conditions are present.

The pressure may not reach 14.5psi (0.1MPa) when the air compressor discharge flow rate is small. Dehumidified drain may flow into the secondary piping if there is a sudden change of pressure or flow speed. Do not use the product where these conditions are present.

If condensate enters the secondary side, it may cause malfunction of pneumatic equipment.

If the lubrication amount is excessive, the oil may accumulate inside the valve, causing malfunction or response delay.

Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. Also, the product may have specified durability, running distance or replacement parts. Please 2.

This may damage the bowl. A metal bowl is recommended in these cases. Protect from ultra violet ray and radiation heat by shield. 3 CAUTION AD17-A and AD27-A with auto drain may leak during exhaust of pressure. (This leakage is allowed in their constructions and not failure.) Be sure to connect piping for drain.

Otherwise, the magnetic force within the actuator may be lost, resulting in malfunction of the auto switch. f. Crack on the back of the belt Workpiece Auto switch 5 mm or more 214