.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Vacuum (Option) Body ported Base mounted Component Parts Description Body Adapter plate End plate Retainer Spool valve Piston Spring Sub-plate Note Platinum silver Platinum silver Platinum silver No. q w e r t y u i Material Aluminium die-casted Aluminium

Increased moisture and dust resistance. q w Enclosure against foreign matters and water is conforming to IP67*. Can be used in an atmosphere where the valve or manifold is exposed by water, etc. directly. ( Based on IEC529) (Refer to the catalog contents for details, as some types of connectors do not meet these standards.)

Material Aluminum alloy Note q Description Plate Body Platinum silver Platinum silver Aluminum alloy Aluminum alloy w e Cap r Aluminum alloy Spacer Platinum silver Platinum silver t Stainless steel/Aluminum alloy Spool y 2 position: Aluminum alloy 3 position: Brass Sleeve u 2 position: Resin 3 position: Stainless steel Piston i Resin Center sleeve o Brass, NBR Side poppet Replacement Parts

Electrical entry q Description 01 02 03 01 02 03 01 02 03 Mounting bolt and gasket are not included. Platinum silver Body C: Conduit VS4010-CSSub-plate Platinum silver Aluminum die-casted w T: Conduit terminal VS4010-TSSpool/Sleeve Stainless steel e U: Grommet, D: DIN terminal VS4010-SReplacement Parts Part no. No.

VH600 Cast iron Cast iron q w Cover Body Replacement Parts Part No. of Lock Nut for Panel Mounting Part no. VH200 244026 244026-1 Series VH200 VH300 VH400 Part no. 244010 24418 240258 Material No.

Zinc die-casted Aluminium die-casted Material Note q Description Valve guide Body Chromated Chromated Chromated Selection w e Handle r Brass Valve Zinc alloy Caution 1. The valve must be switched to each position instantly and securely. Stopping the handle between the extreme positions may cause malfunction. 2.

Model: 42 (Dual AC), Bar Length: 16 (160mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6H (ø6 Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 15 (15m), Bar Bracket: w/o Bracket, DIN Rail Bracket for Controller &

Model: 42 (Dual AC), Bar Length: 142 (1420mm), Emmiter Cartridge, Material: V (Energy Saving High-efficiency Cartridge, Tungsten), High-voltage Cable Length: 2 (2m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: P (PNP), Power Supply Cable Length: 5 (5m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller &

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link

Series: 2 (VQZ200), Composite Symbol: 3 (Rubber Seal N.C.), Function: Standard (0.35W DC, AC), Coil Voltage: 5 (24VDC), Lead Wire: Y (DIN Terminal), Manual Override: Non-locking Push Style, IP65 Compliant: W (IP65 Compliant), Port Size: N7T (1/4" One-touch Fitting), Option: None, CE Compliant: Q (CE Marked)

Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N7 (1/4 inch), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate: T (

Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: M (SI units only), Bracket: S (Bracket (mounting position: Stream side))

Rated Control Flow Range: 11 (1 to 100 L/min), Port Size: N2 (1/4 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: M (SI units only), Bracket: S (Bracket (mounting position: Stream side))

Model: 21 (1.8 m³/min), Input/Output: NPN, Input/Output, Power Supply Cable, AC Adapter: Q (w/AC Adapter, w/AC cord), Bracket: None, Automatic Cleaning Unit, Louver: W (w/Adjustable Louver)

Model: 42 (Dual AC Type), Bar Length: 16 (160mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6H (ø6 Straight), Plug Position: Q (High-voltage Cable Side)

Series: 5 (JSY5000), Type: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: Q [DeviceNetâ„¢ (Version A)], SI Unit Common, End Plate: 4 (Power Supply w/M12 Connector, PNP), I/O Unit Stations: None, Valve Stations: 4 Stations, P,E Port, SUP/EXH Assembly: U (Internal Pilot, U Side, 2 to 10 Stations), A,B Port Size: C10 (ø10 One-touch Fitting), Mounting: D (DIN Rail Mounting), DIN Rail Option

Series: 1 (JSY1000), Type: 10S (Side-Ported, Serial Interface, EX250), SI Unit: Q (DeviceNetâ„¢, Negative Common), Input Block Stations: None, Input Block Type: A (PNP Sensor Input, M12, 2 Inputs), Valve Stations: 16 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C4 (ø4 One-touch Fitting)

Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX250), SI Unit: Q (DeviceNetâ„¢, Negative Common), Input Block Stations: None, Input Block Type: A (PNP Sensor Input, M12, 2 Inputs), Valve Stations: 8 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C6 (ø6 One-touch Fitting)

Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX250), SI Unit: Q (DeviceNetâ„¢, Negative Common), Input Block Stations: None, Input Block Type: B (PNP Sensor Input, M12, 4 Inputs), Valve Stations: 8 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C6 (ø6 One-touch Fitting)