42 22 21 150.5 8 M8 x 1.25 25 to 800 25 to 650 50 35 12 13 10 59 40 27 11 27 21 52 20 10 17 9 32 80.5 70 46 24 28.5 162.5 11 M8 x 1.25 25 to 800 25 to 650 60 35 15 18 10 67 40 26 27 23 64 20 13 17 9 32 98.5 85 48.5 24 28.5 174 11 M10 x 1.25 13.5 25 to 750 25 to 600 70 40 17 23 14 72 52 30 32 23 78 25 15 21 11 37 117.5 102 55 26.5 36 189 13 M12 x 1.75 16.5 25 to 750 25 to 600 80 40 19 25
A Graph 1 Graph 2 120 60 110 B 100 50 C P1 63 63 90 80 40 70 Regulator Circuit C Load weight (kg) Load weight (kg) P2 60 30 50 50 A 50 Regulator valve 40 20 40 40 30 B 32 32 20 10 C P1 10 0 0 0.4 0.3 0.3 0.5 0.6 0.7 Operating pressure (MPa) 0.4 0.5 0.6 0.7 Operating pressure (MPa) Selection example Confirmation of allowable kinetic energy Selection conditions: Transfer direction: Vertical
Lead wire length symbols: 0.5 mNil(Example) C73C 3 m L (Example) C73CL 5 m Z (Example) C73CZ None N (Example) C73CN CA2 CS1 For details about auto switches with pre-wire connector, refer to page 6-16-60.
650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX 2-M5 x 0.8 DCylinder port -X 20Data 2 x 2-M5 x 0.8 Thread depth 10 4-4.3 through 4-8 counterbore depth 4.5 2 x 2-5H7 depth 6 +0.012 0 2-RB0805-X552 Shock absorber (mm) Model F ZZ Z SS S Q P L CXWM16-50 CXWM16-75 CXWM16-100 CXWM16-125 CXWM16-150 CXWM16-175 CXWM16-200 188 152 100 52 164 30 63 35 238 202 125 77 214 60
M6 x P0.5 5.5 M5 x P0.5 4.5 9.5 8.5 71 (17.7) 124 92 Bleed 52.5 63 Exhaust 46 Bleed OUT(2) SUP(1) 43 G OUT 2 SUP(1) OUT(2) 30 50 50 2 x Rc 1/8 9.5 60 35 EXH Pressure gauge port 43 2 x Rc 1/8 Pressure gauge port 35 2 x Rc 1/8 Port size 2 x Rc 1/4 Port size IR300-0 82 60 Mounting hole 12.5 2.3 48 Bracket (Option) Panel mounting hole Max.4 Pressure gauge (Option) Panel When mounting on a panel
(Reduce power consumption by approx. 60%.) 1/1000 1/100 The number of applied pressure errors 3 Setting Modes 3-Step Setting Mode Simple Setting Mode Function Selection Mode Select the setting mode that best meets your needs.
Adsorbent for low dew point Symbol Port size Symbol Size Applicable standard size Power supply voltage Thread type 20 30 40 60 Symbol Description 02 04 06 1 4 1 2 3 4 Symbol Nil Type Rc Single phase 100 VAC (50 Hz) 100 to 110 VAC (60 Hz) Single phase 110 VAC (50 Hz) Single phase 200 VAC (50 Hz) 200 to 220 VAC (60 Hz) Single phase 220 VAC (50 Hz) 0 F G N NPT 1 5 6 134 Heatless Air Dryer ID
Note 2) Drain guide is G1/8 (applicable to size 20), and G1/4 (applicable to size 30 to 60). Note 3) Bracket is not assembled and is supplied loose at the time of shipment. Note 4) Without a valve function. Note 5) For NPT thread type. This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan).
Compressed Air Preparation Filter Compressed Air Purity Class ISO 8573 Main Line Filter AFF Series 1 m Water droplet removal Mist Separator AM Series 0.1 m Oil mist separation and removal Micro Mist Separator AMD Series 0.01 m Oil mist separation and removal Flow Capacity 20% improvement 14.5 m3/min (ANR) *1 AFF AMD AM Pressure Drop 60% reduction 5 kPa or less (For AMD) Weight 52% reduction
Setting range: 0.1/0.2/0.5/1/2/5/10/30/60 s (Initial value 1 s) The analogue input update time is set for every wireless slave unit. Analogue input update time Define the address assignment direction of the EX600 I/O units connected to the wireless master unit. The address assignment direction is changed by mode 1/mode 2. Be careful about the I/O map.
Setting range: 0.1/0.2/0.5/1/2/5/10/30/60 s (Initial value 1 s) The analogue input update time is set for every wireless slave unit. Analogue input update time Define the address assignment direction of the EX600 I/O units connected to the wireless master unit. The address assignment direction is changed by mode 1/mode 2. Be careful about the I/O map.
Thermostat working temp. : 60+/-5 C (at radiating water side) Thermostat ERR14 Alarm 90+/-5 C (at recirculating fluid side) After alarm occurrence : The unit (temp. control, pump) stop.
If operated beyond the limiting ranges, excessive impact will occur and this may cause damage to equipment. 2.00 25 1.50 20 1.00 0.50 0.00 20 30 40 50 60 70 80 90 100 Stroke (mm) Cushion Needle Adjustment Caution : Operating pressure 0.5MPa : Operating pressure 0.4MPa Graph 1 1.
50 Mounting hole IR300-0 IR2120-02 36 2 Bracket (optional) 30 82 Mounting hole Pressure gauge (optional) 60 2.3 48 Bracket (optional) 5.5 9.5 M5 depth 7 75 83 Approx. 119 18 1 1 SMC IN Bleed Pressure gauge (optional) Exhaust SUP(1) OUT(2) OUT 43 Approx. 60 50 50 2-Rc(PT) 1/4 Port size Rc(PT) 1/8 Pressure gauge port M6 x P0.5 15.5 9 82 60 IR3120-0 Mounting hole 48 2.3 76 Approx. 148 22
Output deviation (%F.S.) 0.5 0.5 Out VE 40 0 0 Return VY G 60 0.5 0.5 AL 80 1.0 1 0 2 4 6 8 10 0 25 50 75 100 0 25 50 75 100 Input signal (%F.S.) Input signal (%F.S.)
80 100 120 140 0 10 20 30 40 50 60 70 80 90 100 Flow rate l/min (ANR) Flow rate l/min (ANR) SRP1-01 SRP1101-01 Conditions/Upstream pressure: 0.5MPa Conditions/Upstream pressure: 0.7MPa 0.25 0.50 0.20 0.40 Downstream pressure MPa Downstream pressure MPa 0.15 0.30 0.10 0.20 0.05 0.10 0.00 0.00 0 20 40 60 80 100 120 140 160 180 200 0 20 40 60 80 100 120 140 Flow rate l/min (ANR) Flow rate l
80 100 120 140 0 10 20 30 40 50 60 70 80 90 100 Flow rate l/min (ANR) Flow rate l/min (ANR) SRP1-01 SRP1101-01 Conditions/Upstream pressure: 0.5MPa Conditions/Upstream pressure: 0.7MPa 0.25 0.50 0.20 0.40 Downstream pressure MPa Downstream pressure MPa 0.15 0.30 0.10 0.20 0.05 0.10 0.00 0.00 0 20 40 60 80 100 120 140 160 180 200 0 20 40 60 80 100 120 140 Flow rate l/min (ANR) Flow rate l
Hz 00 01 Without sub-plate Rc 1/8 (6A) Accessory 2 200 VAC, 50/60 Hz Without sub-plate (For manifold) 4 Indicator light (DC is possible only for DL.)
(mm) U H I J K L O Z M N P S A C D E F B Bore size (mm) 32 31.5 M10 x 1.5 60 4.5 14 8.5 9 depth 7 14 34 5.5 Rc 1/8 58.5 73.5 12 16 45 20 65 40 35 M10 x 1.5 69 5 14 8.5 9 depth 7 14 40 5.5 Rc 1/8 66 75.5 12 16 52 22 67 50 41 M12 x 1.75 86 7 18 11 11 depth 8 19 50 6.6 Rc 1/4 80 87 15 20 64 25 76 63 47.5 M12 x 1.75 103 7 18 11 14 depth 10.5 19 60 9 Rc 1/4 93 91 15 20 77 27 80 80 57.5 M16 x 2
Contents 125 CLS125-PS A set of above Nos. 60, 62, 63, 64, 65 & 67. 140 CLS140-PS 160 CLS160-PS Since the lock section for Series CLS is normally replaced as a unit, replacement seal kits are for the cylinder section only.