How to Order VR 12 1 1 F 06 Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 1/8 standard 3.2 23 04 06 01 03 07 1/8" 5/32" 1/4" 4 6 Use 1/8" tubing for 3.2.
How to Order ZFB 100 04 IN/OUT applicable tubing O.D.
RCSK-o15 RCSK-02 RCSK-03 RCSK-04 BCSK-05 RCSK-O5 RCSK-08 RCSK-10 Double Hod clevi6 w/ oin(1). retainina rinos{2) RCDK-015RCDK.02 RCDK{3 RCDK-04 RCDK.OS RCDK.05 RCDK-08 RCDK.lO 'Jah nul sold separatly 'For accessory parl dimensions see cat.
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in10R 1/2AS4201FG-04-10AS4211FG-04-10AS4301FG-04-10AS4311FG-04-10
The SYJA3000/5000/7000 series are 4 & 5 port air operated valves with rubber seals. The series is available in base mounted or body ported styles.Bar stock type manifold for SYJ3000 valves, Supply and exhaust ports common (20, 31, 32, 41 types), Valves individually wired, Maximum 20 stations available as standard, 5 port sizes available, SYJ 5 port valve manifold, 4/5 PORT SOLENOID VALVE
AS1001F-23-3 AS1001F-01-3 38 4.5 16.8 37.6 34.4 1/8" 8.4 38 4.5 16.8 37.6 34.4 8.4 3.2 12.7 12.7 12 10.5 8 AS1001F-04-3 AS1001F-03-3 39.2 5.2 17.4 38.2 35 5/32" 9.3 39.2 5.2 17.4 38.2 35 9.3 4 3.5 3.5 12 8 10.5 AS1001F-05-3 AS1001F-06-3 40.7 6.2 18.5 39.3 36.1 13.5 3/16" 11.4 48.7 16.5 6 11.6 39.3 36.1 6.2 18.5 AS1001F-07-3 AS2001F-04-3 40.7 5.2 20.7 48 42.5 12.7 1/4" 12 40.7 13.7 4 9.3 14
Note 1) 2 1/8, 1/4 3 3/8 4 1/2 Type Metric size Inch size 2 Elbow 3 Universal Tubing O.D. 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" Tubing O.D. 23 3.2 Note 2) 04 4 06 6 08 8 10 10 12 12 16 16 Control type 0 Meter-out 1 Meter-in * Meter-out and meter-in types can be visually identified by color of the knob.
Free flow Controlled flow Weight (g) Sonic conductance dm3/(sbar) Sonic conductance dm3/(sbar) Critical pressure ratio Critical pressure ratio Model Port size Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) AS1000-M3 AS1000-M5 AS2000-01 AS2000-02 AS3000-02 AS3000-03 AS4000-02 AS4000-03 AS4000-04 AS5000-02 AS5000-03 AS5000-04 0.06 20 0.06 20 M3 x 0.5 4.7 0.15 0.22 80 0.25 90 M5 x 0.8 33 0.7
Possible to use in vacuum or under low pressures Vacuum: Up to 101.2 kPa Low pressure: 0 to 0.2 MPa Free mounting orientation How to Order 04 4 5 1 VP3 A G 1 VP series 3 port solenoid valve CE-compliant Q CE-compliant Note) Nil Number of solenoids Single Note) Electrical entry: D/DL/DS/DZ only 1 Body size Thread type 1 4 6 8 1 2 1 2 Rc Nil G F 1 NPT N NPTF T Body ported 5 Body type Pilot
Liquid Collector Ejector Type HEP500-04 AL800 AL900 ALF ALT ALD ALB LMU ALIP AEP HEP AEP HEP Resource Saving/Labor Saving Collects and reuses leaked fluids such as valuable cutting oil and grinding oil Specifications Collects leaked fluids such as valuable cutting oil and grinding oil.
-5 Oil distributor Auto feed tank 1047
ALF400 to 900, ALT-5/-9 Series Operating Pressure Range Tank and line pressure How to Order
1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C.
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
AS1001F-23-3 AS1001F-01-3 38 4.5 16.8 37.6 34.4 1/8" 8.4 38 4.5 16.8 37.6 34.4 8.4 3.2 12.7 12.7 12 10.5 8 AS1001F-04-3 AS1001F-03-3 39.2 5.2 17.4 38.2 35 5/32" 9.3 39.2 5.2 17.4 38.2 35 9.3 4 3.5 3.5 12 8 10.5 AS1001F-05-3 AS1001F-06-3 40.7 6.2 18.5 39.3 36.1 13.5 3/16" 11.4 48.7 16.5 6 11.6 39.3 36.1 6.2 18.5 AS1001F-07-3 AS2001F-04-3 40.7 5.2 20.7 48 42.5 12.7 1/4" 12 40.7 13.7 4 9.3 14
1 Metering Valve with Silencer Series ASN2 Superior sound reducing performance Over 20 dB at max. flow rate Cylinder speed easily set Shape of needle is the same as that of speed controller Retainer prevents accidental loss of needle Model Model Port size Effective area (mm 2) Weight (g) ASN2-M5 ASN2-U10/32 ASN2-01 ASN2-02 ASN2-03 ASN2-04 M5 x 0.8 10-32 UNF 1.8 1.8 3.6 6.5 16.6 24.5 5 5 17
(g) 6 20.7 23.5 4.5 38 8.4 1/8" AS1001F-01 AS1001F-23 6 20.7 23.5 4.5 38.0 8.4 3.2 12.7 10 12.7 10 7 21.4 24.2 5.2 39.2 9.3 5/32" AS1001F-03 AS1001F-04 7 21.4 24.2 5.2 39.2 9.3 4 12 48.7 11.4 16.5 3/16" AS1001F-05 AS1001F-06 8 22.4 25.2 6.2 40.7 11.6 6 13.5 10 6.2 25.2 22.4 9 40.7 12 13.7 1/4" AS1001F-07 AS2001F-04 12 27.6 32.6 5.2 40.7 9.3 4 12.7 11.8 12 27.6 32.6 5.2 40.7 9.3 12.7 5/32"
1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C.
/I.D. mm 8/5 9/6 10/6.5 12/8 12.5/8.5 16/11 Symbol 01 02 03 04 06 Symbol 50 60 65 80 85 110 Symbol 04 06 08 10 12 16 Thread size R, Rc 1/8 R, Rc 1/4 R, Rc 3/8 R, Rc 1/2 R, Rc 3/4 Tubing O.D. mm 4 6 8 10 12 16 Construction