03, 04 100 200 01, 23 100 0 0 5 10 0 0 5 10 Number of needle rotations Number of needle rotations AS4201F, AS4211F AS4301F, AS4311F AS3201F, AS3211F AS3301F, AS3311F 10, 11, 12 12, 13, 16 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 1500 1000 08, 09 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) 06, 07 1000 500 500 0 0 5 10 0 0 5 10 Number of needle rotations Number of needle rotations
D-M9W 10 2 pcs. D-M9WV D-M9AV 5 Note 2) 1 pc. 10 2 pcs. 5 Note 2) 1 pc. D-M9A 10 Note 2) 2 pcs. 5 1 pc. D-M9V 5 2 pcs. 5 1 pc. D-A9V 10 2 pcs. 5 1 pc. D-A9 10 2 pcs. 1 pc. 15 D-P3DWA 2 pcs. 15 Note 1) Confirm that it is possible to secure the minimum bending radius of 10 mm of the auto switch lead wire before use.
P. 11 IDF1E-10 to IDF8E-10 IDU3E-10, IDU4E-10 Base integrated with a transformer A dedicated base for integrating the separately installed transformer and the air dryer.
closed center/exhaust center/pressure center: SYJA3 40-M5 3 4 5 3 4 5 7.1 9 10 2-M3 X 0.5 (Pilot port) 1.8 10 4 A B 1.5 8.2 7 19 2-M3 X 0.5 (Pilot port) (Mounting holes) 3.2 222 3 49 2.5 (Mounting holes) 3.2 2A B 1.5 18.5 11 17.5 (Non-locking) Manual override A B 1.5 33 16 18.9 18.5 21 54.5 13.5 15 Manual override (Non-locking) 21.6 54.5 28.5 R2 P P1 21 1(Bleed port) 2P R R 13 11 0.5 10 5
Width across flat Effective area (mm2) Weight (g) L M d Model 2 x Applicable tubing H1 H2 I.D. 2.5 3 4 6 7.5 8 9 10 13 H1 H2 H2 4 4 6 8 10 10 12 12 16 KFG2H0425-00 KFG2H0403-00 KFG2H0604-00 KFG2H0806-00 KFG2H1075-00 KFG2H1008-00 KFG2H1209-00 KFG2H1210-00 KFG2H1613-00 1.8 2.3 3.3 5.3 6.8 7.3 8 9 12 7 11 25 43 42 44 42 71 1.6 2.6 6 17 30 35 45 57 101 8 8 21.8 5 d 10 14 10 14 24.8 28.6 5.8 6.6
12 10,11 10,11,12 08,09 1000 10 15 8 500 06,07 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 15-9-101 11 Construction ASD230F ASD330F/430F ASD530F/630F ASD530F-02 !
Note) Metric size Inch size With One-touch fitting 01 03 05 07 09 11 04 06 08 10 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 4 6 8 10 For low speed control Note) For applicable tubing O.D. selection, refer to the Model on page 727. Thread type Port size M5 U10/32 01 02 Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT M5 x 0.8 10-32 UNF 1/8 1/4 N Made to Order Lubricant: Vaseline X12 Ex.)
M Weight (g) AS AS221F-U01-23 AS221F-U01-04 AS221F-U01-06 AS221F-U01-08 AS221F-U01-10 AS221F-U02-04 AS221F-U02-06 AS221F-U02-08 AS221F-U02-10 AS321F-U02-06 AS321F-U02-08 AS321F-U02-10 AS321F-U02-12 AS321F-U03-06 AS321F-U03-08 AS321F-U03-10 AS321F-U03-12 AS421F-U04-10 AS421F-U04-12 3.2 4 6 8 10 4 6 8 10 6 8 10 12 6 8 10 12 10 12 7.8 8.9 11.0 15.2 18.5 8.9 11.0 15.2 18.5 11.0 15.2 18.5 20.9
LE CP 1 B A1 1 2 5 6 (17.7) (10.2) (14) (18) A6 B1 B3 A1 A3 B6 (13.5) 1 2 Cable length (L) [m] 15 16 Connector B Connector D (14.7) (30.7) L (11) 1 1.5 3 3 5 5 8 8*1 (10) 8 A B C LE-CP/Cable length: 8 m, 10 m, 15 m, 20 m (*1 Produced upon receipt of order) Controller side (5.5) (6.3) (5.7) (14.2) Connector C A 10*1 Actuator side (Terminal no.)
Outlet: 60 Hz Outlet: 60 Hz 20 20 0.1 0.1 10 10 Outlet: 50 Hz Outlet: 50 Hz Return port Allowable operating range Return port Allowable operating range 0 0 0 5 10 15 20 25 30 0 5 10 15 20 25 30 Circulating fluid flow rate [L/min] Circulating fluid flow rate [L/min] 202 Thermo-chiller Basic Type HRSE Series Dimensions HRSE012/018/024-A-10/20/23 Ventilation air outlet Ventilation air inlet
KFV-04 KFV-06 KFN-04 KFN-06 KFW-04 KFW-06 KFS-04 KFS-06 4/2.5 6/4 KFV-08U 8/5 KFV-08N 8/6 KFV-10U 10/6.5 KFV-10N 10/7.5 KFV-12U 12/8 KFV-12N 12/9 4 6 KFN-08 8 KFN-10 10 KFN-12 12 4/2.5 6/4 KFW-08U 8/5 KFW-08N 8/6 KFW-10U 10/6.5 KFW-10N 10/7.5 KFW-12U 12/8 KFW-12N 12/9 4 6 KFS-08 8 KFS-10 10 KFS-12 12 Precautions Be sure to read before handling.
effective thread depth 8 10 (11) Rod end male threads M M 48 24.5 D D 10 10 2-5.5 through 4-9 counter bore depth 7 36 36 8 20 2-Rc 1/8 (port size) 20 57 + Stroke 5 5 + Stroke 67 + 2 strokes C X L C X L + Stroke 47 32 to 100 2-P (port size) Approx.
1ANR 65% 2 7 3 7 1 8 C 8 C 8-1 8-2 1) 2) 8-3 8 1 9 G G 9-1 9 1 10 H 10 H 10-1 ( ) 10-2 () AD48-2-A 10 IDFA6E-20-H N.O. () 0.151.0MPa 10 1 10 H IDF-S1941 () 1 AD48-2-A 1 1) 2019 3 2019 2 SERIAL No.XP IDF-S1940 IDF-S1938 IDF-S0002 1 C42FP-260S 1 10 2 11 K 11 K 11-1 ( ) 11-2 1.6Mpa AD48-8-A-X2112 10 KQ2H10-02AS IDFA6E-20-K N.O. () 0.151.6MPa 11 1 11 K IDF-S1926
opening [Number of rotations] 2 4 6 8 10 11 1 3 5 7 9 12 0 * The flow rate is not the flow rate output from the vacuum port.
Type Metric size Inch size Elbow Universal 2 3 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 23 3.2 4 6 8 10 12 03 05 07 09 11 13 04 06 08 10 12 Control type Meter-out Meter-in 0 1 Use 1/8" tube.
Model Gripping force per finger Gripping force Note 1) Open/ Close stroke (Both sides) mm Bore size mm 10 16 20 25 Note 2) Weight g Model External Internal 60 125 250 455 4 6 10 14 17 40 66 104 9.8 30 42 65 11-MHZ2-10D 11-MHZ2-16D 11-MHZ2-20D 11-MHZ2-25D In-line electrical entry Lead wire type Explanatory drawing L Note 1) Values based on pressure of 0.5 MPa, gripping point L = 20 mm, at
5.5 M3 x 0.5 8 L 12 7 M4 x 0.7 8 10 A 15 8.5 M5 x 0.8 1214
10 15 15 20 20 2 pcs. 5 10 15 10 20 15 Auto Switch Mounting Bracket Part Nos.
Through-hole/Both ends tapped common (Basic) 10 0.1 0.2 Q 12 (Rod size) G M5 x 0.8 (2 locations) (Port size) Auto switch Minimum bending radius of lead wire 10 R 4 3 E Yh9 S T 3 F M8 x 1.25 Effective thread depth 11 6.8 (The dimension on the opposite side is the same.) 5.5 (2 locations) 13.6 7 10 7 10 M6 x 1 (2 locations) Flat washer With 2 pcs. 9 (2 locations) (The dimension on the opposite