SMC Corporation of America
Elite Part Number Search
Search Results "25A-PFM750-N01-E-MA-W"

(Fig. 1-2) w Bend the reinforcing plate on the nut (M3) side, as shown in Fig. 1-3. e Pass the clip of the switch holder (a) through the square hole in the side of the reinforcing plate that was not bent in step w. (Fig. 1-4 and Fig. 1-5) r Place the switch holder on the cylinder tube in the state of step e. t Wrap the band around the cylinder tube.

V Port G GB HN 2-Rc(PT)P Cushion valve HR MM MO RF D E WL E MB LL Width across flats Effective thread DL MA lC 2 X 4-J F K A N NB lB H S + Stroke ZZ + Stroke Locking at rod end: MBBB Rl Bore size Stroke Locking at both ends: MBBB Wl Bore size Stroke Hl/Rl (mm) Width across flats Bore size (mm) Effective thread length Stroke range (mm) MM MB MA LL K J HN HR H GB G F E DL D lC lB A 32 40 50

ON (+)ON 1 OFF ()ON OFF DC(+)DC(-) 2 ON 80 mA 3 () DC(+)DC(-) NPN PNP ( ) 4 OFF () ( ) 5 () DIN 6 -24No.PS-OMF0005CN-E No. 7 / ( 8 () ) -25No.PS-OMF0005CN-E ISA2-G1 ISA2-G5 ISA2-H1 ISA2-H5 0.010.25 mm 0.030.50 mm (5 m) 30200 kPa 50200 kPa 1.5 20 50 kPa 5 10 L/min (ANR) 100 kPa 8 15 200 kPa 12 22 DC1224 V10 (p-p)10() 15 mA NPN PNP NPN PNP 1 1 1 80 mA 30 V(

Material Replacement Parts Material Note Component Parts VQZ No. q w e r t y No. !0 !

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: L (Bottom), Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None)

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None)

Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None)

Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: L (Bottom), Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: L (Bottom), Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm. When tightening, do not hold the pressure switch body with a spanner. or longer simultaneously.

Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm. When tightening, do not hold the pressure switch body with a spanner. or longer simultaneously.

Over current error The switch output load current is 80 mA or more. , During zero clear operation, pressure greater than 7%F.S. is present. Note that the mode is returned to measurement mode automatically 1 sec. later. The zero clear range varies by 1%F.S. due to variation between individual products.

Over current error The switch output load current is 80 mA or more. Wiring Wiring connections Connections should be made with the power supply turned off. Use a separate route for the product wiring and any power or high voltage wiring. Otherwise, malfunction may result due to noise.

Maintenance Bracket A or D(Model: ZS-24-A/ZS-24-D) Bracket B (Model: ZS-24-B) [01/N01 type] [W1/WF1 type] Operator How to reset the product after power cut or forcible de-energizing The setting of the product will be retained as it was before a power cut or de-energizing.