5 15 10 10 2 pcs. 10 15 20 2 pcs. 5 10 15 15 20 20 25 15 32, 40, 50 32, 40, 50 5 15 10 5 1 pc. 10 10 20 1 pc. 5 5 10 15 15 20 25 15 Besides the models listed in How to Order, the following auto switches are applicable.
Note 7) The display unit is comformed to CE mark. 4 Series PF2A Flow Characteristics (Pressure Loss) PF2A710,510 PF2A750,550 PF2A711,511 3.0 1.0 10 Pressure loss (kPa) Pressure loss (kPa) Pressure loss (kPa) 2.5 0.8 8 2.0 6 0.6 1.5 0.4 4 1.0 0.2 2 0.5 Flow rate (l/min) 0 100 10 25 50 75 5 2.5 7.5 0 5 10 15 20 25 30 40 35 45 50 0 1 10 Flow rate (l/min) Flow rate (l/min) PF2A721,521 PF2A751,551
Table 1 Moment of inertia Size Allowable kinetic energy (J) 10 0.00015 15 0.00025 20 0.0004 30 0.015 40 0.03 How to calculate the load energy E : Kinetic energy (J) I : Moment of inertia (kg m Speed (rad/s) : Rotation angle (rad) 1803.14 rad t : Rotation time (s) 1 E = I 2 2 2 = t Table 2 Safety operable rotation time adjustment range Size Rotation time ( s / 90) 10 0.03 to 0.5 15
Applicable bore size A D L MM N R W Flat type Round type CJ-CF010 CJ-CR010 10 8 10 13 M4 x 0.7 6 10 8 Part no.
10 12 Only R is available.
DS STROKE Bore E B1 B2 B3 TG1 T L1 L3 I1 I2 FL H d1 d2 d3 CN XD 32 45 14 34 3.3 32.5 3 11.5 41 5 5.5 22 10 30 10.5 6.6 10 142 40 55 16 40 4.3 38 4 12 48 5 5.5 25 10 35 11 6.6 12 160 50 65 21 45 4.3 46.5 4 14 54 5 6.5 27 10 40 15 9 16 170 63 75 21 51 4.3 56.5 4 14 60 5 6.5 32 12 45 15 9 16 190 80 95 25 65 4.3 72 4 16 75 5 10 36 16 45 18 11 20 210 100 115 25 75 6.3 89 4 16 85 5 10 41 16 55
J KA KB L M N OB RA RB S U Z , TN, TF , TN, TF 38 10 5 60 58.5 4.5 28 19.8 7 34 5.5 9 7 58.5 31.5 10 M5 x 0.8 10-32UNF M6 x 1.0 1/4-20UNC 14 46 10 5 69 67.5 5 33 23.3 7 40 5.5 9 7 66 35 10 M5 x 0.8 10-32UNF M6 x 1.0 1/4-20UNC 14 58 12 6 86 84.5 7 42 29.7 8 50 6.6 11 8 80 41 14 M6 x 1.0 1/4-20UNC M8 x 1.25 5/16-18UNC 19 7-5-8 9 Series CQM Compact Cylinder: Guide Rod Type Double Acting, Single
Purchasing order is available in units of 10 pieces.
set unit Note 1) Accumulated pulse flow rate exchange value (Pulse width: 50 ms) Note 1) 0.1 l/pulse 0.5 l/pulse 1 l/pulse 2 l/pulse 5 l/pulse l/min, CFM x 10-2 l, ft3 x 10-2 l/min, CFM x 10-1 l, ft3 x 10-1 Display units Real-time flow rate Accumulated flow Note 1, 2) 0 to 9 l, 0 to 9 ft3 x 10-2 0 to 9 l, 0 to 9 ft3 x 10-1 Accumulated flow range Note 1) Power supply voltage Current consumption
M8 x 1.25 5 8 22 16 13 14 12 M8 x 1.25 5 10 22 16 Basic Style (mm) Bore size (mm) A B C D E F H I K L M N OA OB Q RA RB T 20 25 43 37 10 10 36 5.5 M6 x 1.0 43 8 6 22 4.5 M5 x 0.8 7.5 13 10 5 0.8 45 39 10 12 40 5.5 M6 x 1.0 48 10 6 26 4.5 M5 x 0.8 7.5 13 10 5 0.8 6 Series C55 Dimensions 32 to 63 2-G1/8 Port size Auto switch Z Q F 2 x 4-OB counterbore RB H thread effective depth C J E I 4-
They can be ordered in multiples of 10 pieces.
0.06 ST 15, 20 0.04 0.04 ST 15, 20 0.04 ST 5, 10 0.02 0.02 0.02 ST 5, 10 0.00 0 5 10 15 0.00 0 5 10 15 0.00 0 5 10 15 Load [N] Load [N] Load [N] MXZ16 MXZ16 MXZ16 0.15 0.15 0.15 Table displacement [mm] Table displacement [mm] Table displacement [mm] ST 25, 30 ST 25, 30 ST 25, 30 ST 15, 20 0.10 0.10 0.10 ST 15, 20 ST 15, 20 ST 5, 10 0.05 0.05 0.05 ST 5, 10 ST 5, 10 0.00 0 5 10 15 20 25 0.00
VXF(A)2160 Tank 41l 6 x 10 pcs. VXF(A)2160 Tank 41l 6 x 6 pcs. 10 x 12 pcs. 10 x 12 pcs. Without tube (VXF2280) Without tube Without tube (VXF2280) Flow rate Q (Nl) 10 x 12 pcs. 10 x 8 pcs. 10 x 12 pcs. 10 x 8 pcs. VXF(A)2280 Tank 70l 10 x 8 pcs. VXF(A)2280 Tank 70l 10 x 8 pcs. 10 x 10 pcs. 10 x 10 pcs. 100 mm 100 mm 10 x 10 pcs. 10 x 10 pcs. 10 x 8 pcs. 10 x 8 pcs.
Minimum Stroke for Auto Switch Mounting (mm) D-M9 10 D-M9V 5 D-M9W 15 D-M9WV 10 D-A9 10 D-A9V 5 Number of auto switches mounted Bore size (mm) 32 1, 40 50 2, 63 1 10 5 15 15 10 10 2 1 The outline dimensions for 5 mm stroke will be the same as those for 10 mm stroke. 2 The outline dimensions for 10 mm stroke will be the same as those for 15 mm stroke. 7 Prior to Use Auto Switches Common Specifications
M 10 M IDU8E/11E/15E1-10/20 10-1 ( ) IDU Series 10-1 10 1 IDX-OM-W023 10 M 10-2 ADM200 IDU8E15E1-10-M IDU8E15E1-20-M IDF-S0087 IDF-S0090 1.0MPa 1 1 2 / AC100V(50/60Hz) AC200V(50/60Hz) 4W (R1/2) (Rc3/8) Rc1/2 26 Rc1/2 IDU Series 10-2 10 2 IDX-OM-W023 10 M 10-3 Rc1/2 32 25 1) 2830Nm 30 (5) (17)(30) 2 2 Rc1/2 10-4 1-1 IDU Series 10-3 10 3 IDX-OM-W023 11 R
M10 x 1.25 M14 x 1.5 M16 x 1.5 12 M4 10 10 7 5.5 5.5 6.5 M4 set screw (1 pc.) 30 10 16 22 60 46 30 12 M4 10 10 7 5.5 5.5 6.5 36 12 16 30 80 56 40 12 M5 12 13 7 9 7 10 M5 set screw (1 pc.) 44 12 24 30 88 64 43 16 M5 12 13 9 9 10 10 Y-type double knuckle joint Bracket pin 20: Y-020B 25: Y-032B 32: Y-04D 40: Y-04B 2 x D drill through RR1 RR1 C1 Chamfer NDH10 NDH10 MM C E1 E1 C1 Chamfer NZ NZ
One-touch fitting 06 08 10 6 One-touch fitting 8 One-touch fitting 10 One-touch fitting Power supply cable Refer to the table below for selection of One-touch fittings.
10-ASD330F-01-08 10-ASD230F-M5-06 2.
Throttle valves and dual speed controllers for recommended speed adjustment of CYP cylinders Model CYP15 CYP32 Series Throttle valve 10-AS2200-01-X214 Elbow type 10-AS1200-M5-X216 Metal body piping type 10-AS2000-01-X209 In-line type 10-AS1000-M5-X214 10-AS2201F-01-04-X214 10-AS1201F-M5-04-X214 Operation Elbow type (throttle valve) 10-AS2201F-01-06-X214 10-AS1201F-M5-06-X214 10-AS2201F-01