port regulator) ARB310-00-B ARB210-00-B Can be made into manifold with series VV72.
4 (B) 2 Note 1) According to JISB8375-1981.
Flow Characteristics/Weight Flow characteristics 1 2 (P A) 2 3 (A R) 3 2 (R A) 2 1 (A P) Port size Weight Valve model Grommet C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VT307 VT307V (Vacuum spec. type) VT307E (Continuous duty type) VT307Y (Energy-saving type) VT307W (Energy-saving, Vacuum spec. type) VT307 VT307V (Vacuum spec. type) VT307E
Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VT325 VT325V (Vacuum spec. type) VT325 VT325V (Vacuum spec. type) 0.55 kg (For AC) 0.60 kg (For DC) Note) Values for a single valve unit.
) The IN air passes the check valve to pressure boosting chambers A and B.
T Body size Pilot type Valve stations Port size 1 22 2 stations P , R A Internal pilot 0 1 For VY1B0 B 01 1 8 2 Common external pilot 210 2 10 stations 2 stations 1 Internal pilot 0 1 For VY120 2 1 4 02 2 Common external pilot 8 2 8 stations 3 8 1 4 A B C 2 stations 1 Internal pilot 0 1 For VY140 3 8 4 2 Common external pilot 3 8 1 2 6 Dimensions 6 stations VVEXB Connection mark All types
(kg) -E 0.21 0.21 0.21 -EL 0.26 0.26 0.26 -M 0.27 0.27 0.27 -ML 0.32 0.32 0.32 Without switch 0.17 0.17 0.17 Model ZM2 ZM4 ZM6 ZM1-J ZM3-J ZM5-J ZM1-K ZM3-K ZM5-K ZM1-A ZM3-A ZM5-A ZM1-B ZM3-B ZM5-B ZM0.24 0.28 0.33 0.34 0.39 0.25 0.29 0.34 0.35 0.4 0.25 0.29 0.34 0.35 0.4 0.26 0.3 0.35 0.36 0.41 P Q 0.24 0.28 0.33 0.34 0.39 -04R/L 0.209 0.214 0.219 0.224 0.229 0.234 0.239 0.244 0.249 0.254
Note 2) 400 V type is provided with an earth leakage breaker -B as standard.
Symbol (B) 2 (A) 4 1 (P) 3 (R) Flow Rate Characteristics C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 14/2(PA/B) 4/25/3(A/BEA/EB) Flow rate characteristics Valve model Port size Body ported 10-VQD1121(V)-L M-M5 10-VQD1121 -L M-M5 10-VQD1151(V)-L M-M5 10-VQD1151W-L M-M5 0.05 0.07 0.06 0.07 Base mounted (With sub-plate) 0.22 0.27 0.22 0.27 0.16 0.24 0.10 0.25 0.05 0.07 0.05 0.07 0.19 0.28 0.22 0.27
Endurance 10 G; X, Y, Z directions, 3 times each Impact resistance 350 g or less Weight 1) 90 phase difference input Multi-counter/Dimensions A phase I 24-M3 x 0.5 B phase J A B C D A COM COM COM B 12 VDC GND F.G.
Although A, B+ and B marks are indicated on the terminal block, this can be used as either +COM or COM.
Effective area (mm2) Weight (g) Dimensions (mm) 20 35 1 5 9.5 20 1 3.3 22.5 38 9 17 11 A B 13 6 8 Note) NPT thread for AN101 and AN110 is alsoavailable.
(Values at the initial period) Note 3) At rated voltage Flow Characteristics/Weight Flow characteristics 1 2 (P A) 2 3 (A R) 3 2 (R A) 2 1 (A P) Weight Valve model Grommet C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VT317 VT317V (Vacuum spec. type) VT317E (Continuous duty type) 0.29 kg 2.4 0.26 0.62 2.6 0.34 0.67 2.8 0.25 0.67 2.5 0.37 0.66
Green Between case and AC line: 500 VDC, 50 Mor more GND 32 to 122F (0 to 50C) (No freezing) Ambient temperature F.G.
Flow-rate Characteristics/Weight Flow-rate characteristics 1 2 (P A) 2 3 (A R) 3 2 (R A) 2 1 (A P) Port size Weight Valve model Grommet C[dm 3/(sbar)] b Cv C[dm 3/(sbar)] b Cv C[dm 3/(sbar)] b Cv C[dm 3/(sbar)] b Cv VT307 VT307V (Vacuum spec. type) VT307E (Continuous duty type) VT307Y (Energy-saving type) VT307W (Energy-saving, Vacuum spec. type) VT307 VT307V (Vacuum spec. type) VT307E
Replacement method Standard replacement period Refrigerating compressor 1 B 20,000 hours (6 years) Plate type heat exchanger 1 B 20,000 hours (6 years) Water regulating valve 1 B 20,000 hours (6 years) High pressure switch 1 B 20,000 hours (6 years) Low pressure switch 1 A 20,000 hours (6 years) Magnetic contactor 1 A 20,000 hours (6 years) Programmable controllers 1 A 20,000 hours (6 years
Circulating fluid return port When heating the circulating fluid, the high-pressure, high-temperature refrigerant gas is bypassed into the evaporator by expansion valve B to heat the circulating fluid. The combination of the precise control of expansion valve A for cooling and expansion valve B for heating allows for high temperature stability.
Optuon B ventilation air outlet Earth leakage breaker Handle Lid for circulating fluid fill port (There is a handle on the other side too.)
Cv b Cv b Cv b Cv Grommet VTA315 1.6 0.30 0.39 1.7 0.39 0.45 1.9 0.38 0.49 1.7 0.36 0.45 0.16 VOA315 1.4 0.12 0.33 1.2 0.18 0.29 1.5 0.16 0.35 1.2 0.13 0.28 Construction/Dimensions Precautions Breathing port of diaphragm Pilot port Rc 1/8 Be sure to read before handling.
For driving air operated valves for fluid control N.C N.O N.C N.C Air operated style fluid control valve Vacuum valve Vacuum pad A, B 1(P) A, B 1(P) A, B 1(P) A, B 3(P) 3(R) 3(R) 3(R) 1(R) Vacuum releasing air Atmospheric pressure or micro pressure The characteristic values shown in the catalog are representative values, not warranting the performance. 4-3-1 2 Series SY100 Precautions Be