SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2F50-700-E-A93"

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 650, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewied Connector: L (3m)

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal

A B Reed auto switch: D-A93 Stroke B Stroke E Auto switch operating range Model A 100 40 50 150 30 75 125 150 10 20 30 125 75 100 20 50 10 40 13-/22-MXQ6(L) 13-/22-MXQ8(L) 13-/22-MXQ12(L) 13-/22-MXQ16(L) 13-/22-MXQ20(L) 13-/22-MXQ25(L) 6 4.5 5.5 5.5 13.5 5.5 13.5 1 1 1 9 9 7.5 5 12 32 8 31 8 16 3.5 3.5 7.5 11.5 26.5 27.5 11.5 6 40.5 14.5 40.5 14.5 21.5 24.5 21.5 20 10 10 17 17 36 36

6 q e r t !5 w !4 CUJ CU CQS CQM CQ2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com !0 u y RQ MU 32 to 50 With auto switch (Built-in magnet) !6 q e r t !5 i o !1 !3 !2 !7 w !4 D-X 20Data !0 u y Description No.

C D (KF) KF (K) KF G I H H V Fn Fd A C C U U M E V V A L E B K S H J M G A A A B C D E Fn Fd G H J K XLD-25 50 123 48 1 12 40 26 41 16 7.5 XLD-40 65 170 66 2 11 55 41 63 20 15 XLD-50 70 183 79 2 11 75 52 68 20 17.5 XLD-63 88 217 100 3 11 87 95 70 72 20 20 XLD-80 90 256 117 3 11 114 110 83 98 20 26.5 XLD-100 108 321 154 3 11 134 130 102 133 20 38 XLD-160 138 335 200 3 11 190 180 153 114

Dimensions/12 to 25 Standard (Through-hole/Both ends tapped)/CQSYB, CDQSYB 12 2-M5 x 0.8 Auto switch Lead wire min. bending radius 10 H thread effective depth C 2 x 4-OB counter bore depth RB 2 x 4-OA effective depth RA Note 1) Q F 16 I 4-N through D M E T Plain washer K B + Stroke L M A + Stroke E 20, 25 Rod end male thread H1 Rod end nut Note 2) C1 X L1 Rod end male thread Bore size (mm

7 q e @0 !0 o @2 @3 !5 u t !8 @1 r @4 w 12 to 40 @7 !1 !7 q !6 !0 @2 @3 o @4 @6 y e r !8 @1 @5 u w Rod cross section for 12, 16, 20, and 25 Rod cross section for 32 and 40 With end lock 12 to 40 y !7 !6 q !0 o @2 @3 @4 @6 e r !8 @5 @1 i @8 !4 !5 !2 @9 !3 w Parts list No. 1 2 3 4 5 No. Description Rod cover Head cover Cylinder tube Piston Spacer for switch type Description Qty.

K 2P (port size) M Q Q End lock mechanism dimensions (mm) B + Stroke L J E Bore size (mm) HN (Max.)

./0.05 MPa Ambient and fluid temperature 5C to 60C Port size Rc1/4 (Gauge port Rc1/8) Weight Approx. 700 g (at 100 mm stroke) Construction/Principle of Operation When signal pressure enters input chamber q, the input diaphragm e is deflected left. Clearance of the nozzle y is reduced causing higher back pressure at diaphragm A u.

ITV End Block IC O-ring ARM5 E L A ITVH ITVX End block Air supply specification Air supply speicification Symbol 1 2 PVQ Centralized supply Manifold mounting Individual supply VY1 Mounting Symbol A B 1 Applicable for the end block on the right side only.

d e. 6. f. g. ( ) h. i. 7. j. k. l. 2. 8. ,,, 9. 1. 10. 2. 11. 3. 1. 1. 0.11.0MPa 0.30.5MPa :060 2. 3 2. 1. 3. 5 2. 35% 1. ( 6 ) ()70% ()35% 2. 50% ( 6 ) 15% 3. 1. 4. () 0.5 3. 5. F.G. 4. 1. 1. 2. 2. 3. 1. 1. 2. 2 3. 2. 1.52 4. 5. 1. 1ISO VG32 1. 2. 1. 2. 3. 1. 2. 1. 2. 14.5mT CE2 3. 15,000 18cm 4. 3. 4. IP65 5.

(F) C (10, (10 1m) 1m) J K L2 N1 M P 13 4x H (911)[] 911)[] mm A B C D E F G H J K L M N P IDU22E R1 325 775 1153 93 445 1235 279 353 600 379 46 85 IDU37E R11/2 360 1258 64 550 1350 290 388 680 414 50 13 IDU55E 855 1345 1440 R2 470 53 530 360 36 500 75 700 526 IDU75E 1480 1575 70 IDU Series 6-2 GWP 6 2 IDX-OM-W029 6 6-4 IDU22E-23 IDU37E-23 GFCI For Option R GFCI R GFCI For Option

A90 A90V No Reed switch Solid state switch 2 wire 24V A93 A93V Grommet 100V 12V Yes 3 wire (NPN equiv.)

1 OPEN o e CLOSE OPEN For 200 mm wafer For 300 mm wafer XGT22 XGT31 XGT22 (200 mm wafer type) Component Parts XLA No.

Auto switch model Lead wire length (m) 0.5 (Nil) 3 (L) 5 (Z) Load voltage Indicator light Applicable load Perpendicular In-line Special function Type Electrical entry Wiring (Output) AC DC 100 V A90 A90V 5 V, 12 V 100 V or less IC circuit No Relay PLC 24 V Reed switch Solid state switch 2-wire A93 A93V 12 V Grommet Yes A96 A96V IC circuit 5 V 3-wire (NPN equiv.)

With air cushion 4-FD E-0.05 0 FT F FX0.15 B (mm) Bore size 40 B 61 E 25 F 2 FX 46 FD 6.6 FT 8 50 63 76 92 30 32 2 2 58 70 9 11 9 9 Note) End boss is machined on the flange for E.

6 e !0 !3 w @1 @2 !5 t y q r e !0 !3w #0 @9 #3 @8 @7 o @0 !6 i !9 !8 u o @0 !7 i !9 !