U S C E Padlock mounting position D C Padlock mounting position D SUP. SUP A B A B IN OUT IN OUT 2 1 3 EXH. EXH.

J Bracket (Option) AR20(K)-B to AR40(K)-06-B 2 x P1 Panel fitting dimensions A (Port size) Y W C B Q V K OUT OUT IN IN Z Plate thickness AR20(K)-B to AR30(K)-B: Max. 3.5 AR40(K)-B : Max. 5 R F P2 S (Pressure gauge port size) Bracket (Option) U M J D T N AR50(K)-B/AR60(K)-B 2 x P1 A (Port size) B Q C K OUT IN R F P2 S (Pressure gauge port size) Bracket (Option) T N J M D U 73 Regulator Series

(L) Dimensions n: Stations L n 19 226 218 20 237 229 13 160 152 15 182 174 17 204 196 5 72 64 6 83 75 7 94 86 9 116 108 11 138 130 L2 L1 2 39 31 3 50 42 4 61 53 16 193 185 18 215 207 10 127 119 12 149 141 14 171 163 8 105 97 601

Printed in Japan. 1st printing September, 1999 D-SMC.L.A. P-80 (D)

Refer to p.4.1-74, 4.1-75 for specifications and models.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75/20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket: Through

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 75mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewied Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector)

Mounting: B (Through Hole), Bore Size: 32mm, Thread: TN (NPT Thread), Full Stroke: 75mm, First Stroke: 20mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector)

Bearing Style: Slide Bearing, Bore Size: 50mm, Port Type: -, Stroke: 75mm, Locking Direction: Retraction Stroke Lock, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M12-4 Pin Connector, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 75mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewied Connector: 1.0m Cord Length, M12-4 Pin Connector, Number: -

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75/20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket: Through

SUP. 3 1 2 3 1 2 3 1 2 E Padlock mounting position D C SUP J 2 2 x K A T IN OUT AA 3 L 2 x P1 (Port size) B V BB U Built-in silencer (Option) M (Width across flats) 3 N P2 (Port size) Q EXH Y Bracket (Option) R S X W Dimensions (mm) Standard specifications Model P1 P2 A B C D E F G H I J K L M 1/8, 1/4 1/4, 3/8 1/8 1/4 3/8 1/2 1/2 66.4 80.3 104.9 110.4 134.3 22.3 29.4 38.5 42 53 40 53 70

C E E (KF ) Fn J H B A G A mm A B C D E Fn G H J XLC-16 40 110 38 1 30 17 40 26 XLC-25 50 120 48 1 12 40 26 39 27.5 XLC-40 65 171 66 2 11 55 41 63 36 9 XL-OMV0002 4-2.162580,100,160 C E D C E E (KF ) (K ) Fn Fd J K H B A G A mm A B C D E Fn Fd G H J K XLC-50 70 183 80 31 10.5 75 52 77 29 10.5 XLC-63 88 209 100 39 11 87 95 70 76.5 36 9 XLC-80 90 250 117 45.5 11 114 110 83 105 44 9 XLC-100

Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Fig. 3-13 Connection of RS-232C HRS Series 3.3 Installation 3-25 HRX-OM-W032 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly. Incorrect piping might cause leakage of supplied or drained fluid and wet surrounding area and facility.

How to Order B 40 30 D CQ2X Without auto switch With auto switch CDQ2X A73 B 40 30 D Number of auto switches With auto switch (with built-in magnet) Auto switch type 2 pcs. 1 pc. "n" pcs. Nil S n Nil Without auto switch (with built-in magnet) Microspeed cylinder Select auto switch model number from the table below.

Two mounting styles Table traveling accuracy C D Bottom mount Top mount Model Traveling accuracy C side against A side D side against B side LG1H 0.1 or less 0.1 or less A B Variations Mounting orientation Lead screw type Motor type Guide type Motor/Screw connection Series Standard motor [Tamagawa Seiki Co., Ltd.]

The valve arrangement is numbered as the 1st station from D side. Under the manifold base part number, state the valves to be mounted in order from the 1st station as shown in the figure above. Refer to page 1520 for manifold options. 1519 VFA3000/5000 Series Manifold Options For base mounted Blanking plate assembly Mounting screw, gasket part no.