SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2A40-50DMZ-M9N"

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: Double Knuckle Joint, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25

CK1 Load voltage Auto switch model Lead wire length (m) Pre-wired connector Applicable load DC AC Band mounting Rail mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line Perpendicular In-line Indicator light Type Special function Electrical entry Wiring (Output) C(L)K M9NV M9N M9NV M9N V V V v v IC circuit 3-wire (NPN) C(L)KU 5 V,12 V 3-wire (PNP) M9PV M9P M9PV M9P V V V v

How to Order [Option] XLGV M9N 16 A 1 G L Flange size 16, 25, 40 1 q e u r t XLGV M9N 50 A 1 G L Flange size 50, 63, 80 i w y o !0 !

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

Data Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL Auto Switch Mounting Bracket Part No.

D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.

Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Band mounting Rail mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line Perpendicular In-line Indicator light Type Special function Electrical entry Wiring (Output) M9NV M9N M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V 3-wire (PNP) M9PV M9P M9PV M9P V V V v v Grommet Solid

Lead wire length symbols: 0.5 mNil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Refer to page 10-12-16 for details on other applicable auto switches than listed above.

Chemraz is a registered trademark of Greene, Tweed Technologies, Inc. 10 XLF/XLFV Series Air Operated, With Solenoid Valve Solenoid valve How to Order [Option] w XLFV 16 2 G M9N A y 1 G q e i r t u o !

SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.? Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving?ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,?

SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.? Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving?ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,?