This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2 COMPACT CYLINDER, PE, 63MM CQ2 DBL-ACT AUTO-SW, 1.73920 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, PE, 63MM CQ2-Z DBL-ACT AUTO-SW, .00000 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, PE, 63MM CQ2-Z DBL-ACT AUTO-SW, 2.22046 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, PE, 63MM CQ2 DBL-ACT AUTO-SW, 2.39353 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, PE, 63MM CQ2 DBL-ACT AUTO-SW, 2.39353 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, PE, 63MM CQ2 DBL-ACT AUTO-SW, 2.64554 lb
Load voltage Auto switch model Lead wire length (m) Pre-wired connector Applicable load Applicable bore size Indicator light Type Special function Electrical entry Wiring (Output) DC AC 20 to 63 80, 100 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line In-line M9NV M9N IC circuit 3-wire (NPN) G59 5 V, 12 V 3-wire (PNP) M9PV M9P G5P Grommet 2-wire 12 V M9BV M9B K59 Connector H7C
Lead wire length [m] Pre-wired connector Applicable load 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) DC AC Perpendicular In-line Special function Wiring (Output) Load voltage Auto switch model Lead wire type Indicator light Applicable size Electrical entry Type M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V 3-wire (PNP) M9PV M9P V V V v v 2-wire 12 V M9BV M9B V V V v v 3-wire (NPN) 5 V
Use taps on the bottom. 758 A Solid State Auto Switch Direct Mounting Type D-M9N(V)/D-M9P(V)/D-M9B(V) RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-M9, D-M9V (With indicator light) 2-wire load current is reduced (2.5 to 40 mA).
Weight (g) D-M9P(V) D-M9B(V) D-M9N(V) Auto switch model 0.5 m (Nil) 8 7 1 m (M) 14 13 Lead wire length 3 m (L) 41 38 5 m (Z) 68 63 Dimensions (mm) D-M9 D-M9V Mounting screw M2.5 x 4 L Slotted set screw (flat point) 500 (1000) (3000) (5000) Indicator light 2.6 3.95 Mounting screw M2.5 x 4 L Indicator light 2.8 Slotted set screw 2 7.5 0.3 22.8 2.6 15.9 4.6 2.8 2.6 19.5 2.6 6 Most sensitive
Prepare an auto switch mounting bracket (BMY3-016) when mounting the auto switch on to the EQFS32/40H. 29 Solid State Auto Switch Direct Mounting Type D-M9N/D-M9P/D-M9B Refer to the SMC website for details on products that are compliant with international standards.
D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.
In-line In-line Perpendicular Perpendicular 3-wire (NPN equivalent) IC circuit 5V A76H A96 A96V Grommet A72H A73H 200 V A72 A73 A73C A93 A93V Reed switch Solid state switch Yes 100 V Relay, PLC 2-wire 12 V 24 V Connector Diagnostic indication (2-color indication) A79W Grommet F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV 3-wire (NPN) 3-wire (PNP) F79 F7P J79 F79W F7PW J79W F7BA M9N M9P