Refer to page 100 for part numbers. 105 Made to Order/Clean Room Specification Series LJ1H20 Dimensions/LJ1H202 (X60) Scale: 15% When two dimensions are shown, the top dimension is for 100 to 600mm strokes, and the bottom dimension is for 700 to 1200mm strokes.

VQZ235 Rubber 12.6 (0.7) 15 or less 20 or less 53 VQZ200 VQZ225 Metal 10.0 (0.55) 14 or less 18 or less N.O. VQZ245 Rubber 12.6 (0.7) 15 or less 20 or less VQZ315 Metal 16.2 (0.9) 17 or less 22 or less N.C. VQZ335 Rubber 21.6 (1.2) 25 or less 33 or less VQZ300 77 VQZ325 Metal 15.3 (0.85) 17 or less 22 or less N.O.

M2 3.0 5.2 9.0 15 24 38 60 3.0 5.0 8.5 14 23 35 50 M3 1.0 1.7 2.4 5.0 8.0 15 19 2.0 3.0 5.0 10 20 35 50 m2 7 10.4 15 23 33 48 72 7 10 14 21 30 42 60 m3 2.1 3 4.5 6.6 10 14 21 2.1 3 4.2 6 8.2 11.5 16 16 20 25 32 40 50 63 16 20 25 32 40 50 63 MY1MW MX MTS MY MY1CW CY MG The above values are the maximum allowable values for moment and load.

Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 100mm, Port Thread: TN (NPT; ø50 to ø100), Stroke: 15mm

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Without built-in magnet, Support bracket: Without auto switch mounting

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Without built-in magnet, Support bracket: Without auto switch mounting

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber bumper (standard), Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Support bracket: None, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber bumper (standard), Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Support bracket: None, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber bumper (standard), Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Support bracket: None, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 8, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber bumper (standard), Operating Pressure(MPa): 0.1 to 1.0, Specification: Without magnet, Support bracket: None, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber bumper (standard), Operating Pressure(MPa): 0.08 to 1.0, Specification: Without magnet, Support bracket: None, Auto Switches: Without