SMC Corporation of America
Elite Part Number Search
Search Results "HRS060-AN-20-J"

The apparent power in parentheses is for VXZ2232. 50 66(60) 20 60 57(51) 15 AC VXZ22 DC 50 93 25 60 79 20 AC VXZ23 DC JIS Symbol OUT IN 17-3-63 Applicable Fluids Check List Refer to pages 17-3-62 and -63 for models and specifications. Refer to pages 17-3-62 and -63 for models and specifications.

Model Exhaust Piping/Port location Port size Applicable P R 1 A,B P It A,B Valve NWsF5-20Common Side /Base Side/Base fop/ Valve %NPrF I %flPlf LNPIF %NPIF NVFSO20 DXT 156-20-1TA EXH relocation spacer NVV5F5-20 156-19-14 NW5F5-20 " Spacer is used when it is nscessary to exhaust from certain valves individually.

(Mounting position: Horizontal) W 1000 500 400 Allowable lateral load W (N) 300 Allowable kinetic energy 200 Piston speed 200 180 200 100 180 Piston speed Allowable kinetic energy 20 to 400mm/s 12.4J 50 40 30 (m1 + m2) V Kinetic energy E (J) = 2 m1: Weight of moving cylinder parts kg m2: Load weight kg V: Piston speed m/s 20 10 0 20 40 60 80 100 120 140 160 180 200 220 260 240 280 300 Kinetic

It cannot be used if connected in the opposite direction. 4.6-24 Series AME Dimensions: AME150 to AME350 M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 146 167 167 198 198 I 56 66 66 80 80 J 15 20 17 22 19 K 5 8 8 8 8 L 9 12 12 14 14 N 35 40 40 50 50 O 54 66 66 80 80 P 70 84 84 100 100 Q 26 28 28 34 34 R 4.5 5 5 5 5 S 1.6 2.0 2.0 2.3 2.3 1/8, 1/4, 3/8

: 201 to 300mm 80 40 50 50 20 20 Load weight m (kg) Load weight m (kg) Load weight m (kg) 20 10 10 10 63 63 63 5 5 5 50 50 50 [Example ] 40 40 40 1 1 1 70 100 300 500 1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.

hole: G1/2 LQ LVN Manual override (Non-locking) TI/ TIL Pilot port PA PAX PB Main port Main port Rc Pilot port Rc A B C D E F H J K L Model 1 8 1 4 1 4 VNC5-32A VNC6-40A VNC7-50A 1 4 1 2 1 1 2 105 120 140 77 96 113 53 60 74 26.5 30 37 120.5 137 160 20 24 24 129.5 147 170 229.5 247 270 197 214.5 237.5 55 63 74 17-4-25 6 Series VNC Flange Type Port size: 32F, 40F, 50F Electrical entry hole

Note) The minimum bending radius of the D sub connector cable is 20 mm. Insulation resistance Mkm, 20C (68F) 5 or more 16 44 8 SMC Connector manufacturers Fujitsu Ltd. Japan Aviation Electronics Industry, Ltd. J. S. T. Manufacturing Co., Ltd.

An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 1.

20 0.5 0.4 0.3 0.2 0.5 0.4 0.3 0.2 25 20 16 16 12 12 0.1 0.1 0 40 60 80 100 120 140 160 180 200 20 20 0 40 60 80 100 120 140 160 180 200 Overhang L (mm) Overhang L (mm) Graph (20) Stroke: Up to 150 stroke Graph (16) Stroke: Up to 150 stroke 10 20 10 20 2 3 4 5 2 3 4 5 Weight W (kg) Weight W (kg) 40 40 32 32 1 1 0.5 0.4 0.3 0.2 0.5 0.4 0.3 0.2 25 25 20 20 0.1 0 40 60 80 100 120 140 160 180

Both input and output sizes are shown for an input / output unit. In / Out size Input data "--" is displayed for an output unit. Displays input data value which is sent to an input unit or input / output unit. Output data "--" is displayed for an input unit.

Ambient temperature 0 to 40C (No freezing) Ambient humidity 35 to 65%RH (No condensation) Material Case: PBT Emitter: Tungsten Weight (Body only) Standard nozzle 200 g Bypass nozzle 250 g Standards/Directive CE (EMC directive, RoHS directive), UKCA Ambient humidity 20 to 80%RH Safety standards IEC 62368-1 *4 An AC cord included with an AC adapter is only for use in Japan.

The area of one pad can be divided to an equivalent area of multiple pads (n) as necessary, based on these forces and the shape of the load. Calculation Method: Pad Diameter A vacuum pad diameter with applied safety factor based on lifting orientation of workpiece (vertical or horizontal) can be derived from calculations or by using the Selection Graph shown below.

Solenoid Specifications Apparent power (VA) Inrush Holding Power consumption (W) (Holding) Temperature rise (C ) (Rated voltage) Frequency (Hz) 50 25 12 60 20 8 Model Power source 5 50 3.5 35 6 50 8 55 6.5 45 8 50 0.5 60 9.5 50 11.5 55 Note) They are values in an ambient temperature of 20C 5C and application of rated voltage.

This may also have an adverse effect on the peripheral equipment in proximity. Should a valve be continuously energized for long periods, or its daily energized state exceeds its non energized state, please use a valve with DC specifications.

Note 8) Min. operating pressure = 0.1 MPa Note 9) If a compact pressure switch is mounted later on, an elbow (R x Rc) is necessary. Mist separator and regulator are combined together. Filtration 0.3 m Space-saving and easy piping.

~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC Material Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Courtesy of Steven Engineering, Inc. !

H G I J K L A B C D E F M R Size Tolerance +0.058 0 -0.1 -0.2 -0.1 -0.2 -0.1 -0.3 -0.1 -0.3 AD-FI-20 AD-FI-25 AD-FI-32 AD-FI-40 +0.027 0 +0.027 0 +0.027 0 +0.027 0 9 9 16 16 36 38 55 55 16 18 22 22 9 9 12 12 20 25 32 40 10 10 15.5 15.5 20 20 24 24 14 14 20 20 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 20 25 32 40 46 46 56 64 28 30 40 43 60 60 80 88 22 22 30 30 16 16 16 24 10 10 12 12 30 30

CH2-4 has one output each. 4 Multi-channel Digital Sensor Monitor PSE200A Series 3-Screen Display IO-Link is an open communication interface technology between the sensor/ actuator and the I/O terminal that is an international standard, IEC61131-9.