.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Bracket Nil B None With bracket Electrical entry G Grommet Solenoid valve option C Conduit Nil Standard D DIN terminal Select an option mark in page 17-3-64 by Applicable Fluids Check List for special fluids outside of the standard.
PUSH TURN Precaution Insert/remove the connector vertically, not at an angle. LOCK Applicable cable Cord O.D.: 3.5 to 7 (Reference) 0.5mm2 2-core and 3-core wires equivalent to JIS C 3306.
Take appropriate measures to avoid freezing of drainage, moisture, etc. q When the valve is installed in an atmosphere where there is a lot of dust, install a silencer into the port "3(R)". When dust enters the valve from the port "3(R), it may cause malfunction. w Operation method To stop the valve midway can cause malfunction.
Please use an appropriate dryer to ensure dry air and prevent the valve lrom lreezing. The double solenoid valve must be energized for at 0.1 seconds or more to ensure proper operation. Re c omm ended L ubricants for SMC Pneumatics'Vah:es Lubrication OThe valve has been lubricated for life at manufacture, and does not rquire further lubrication in service.
There may be the case it will vary substantially depending on an ambient environment.
Set value IO-Link is an open communication interface technology between the sensor/actuator and the I/O terminal that is an international standard, IEC61131-9. *1 IODD File: IODD is an abbreviation of IO Device Description. This file is necessary for setting the device and connecting it to a master. Save the IODD file on the PC to be used to set the device prior to use.
(Effective for up to the number of set channels) Interrupting an operation via an external switch is possible using input signals.
The load should be applied to the piston rod in an axial direction.
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4.
The load should be applied to the piston rod in an axial direction.
AXT100-DR7 L dimension Select L dimension from the table below and enter an applicable symbol.
Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. (3) Connecting the wireless unit. After connecting the required I/O units, connect the wireless unit.
Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. (3) Connecting the wireless unit. After connecting the required I/O units, connect the wireless unit.
In the case of obtaining an accurate flow rate, refer to front matter pages 1 to 6.
Fit an auto switch into the auto switch mounting groove to set it roughly to the mounting position for an auto switch. 4. After confirming the detecting position, tighten up the mounting screw (M2.5) attached to an auto switch, and secure the auto switch. 5. When changing the detecting position, carry out in the state of 3. 1.
An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. d. When used in an interlock circuit, dual interlock such as mechanical protection is necessary in case of accident. Periodical inspection is also necessary to confirm proper operation.
Therefore, if an external stopper is used to stop the piston rod and the lock is engaged, the piston rod will shift in the amount of its axial play. 6. To effect an intermediate stop, take the cylinders stopping precision and overrun amount into consideration.
How to Use L/M Plug Connector Manual Override Caution Warning Without an electric signal for the solenoid valve the manual override is used for switching the main valve. Non-locking push type (tool required) is standard. Locking type (tool required) is available as an option.
The product does not have an explosion proof construction. Be sure to take measures to prevent the area around the product from becoming filled with an explosive gas, when using an explosive fluid. 56
Note) The -X126 model cannot be manufactured with an L plug connector for electrical entry. Therefore, use a grommet type or an M plug connector.