SMC Corporation of America
Elite Part Number Search
Search Results "ISE20A-X-M5-J"

Port size M5 01 02 03 04 M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 With One-touch fitting Clean specifications Metal parts material Q G Brass (electoless nickel plated) Stainless steel 304 Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.

Port size M5 01 02 03 04 M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 With One-touch fitting Clean specifications Metal parts material Q G Brass (electoless nickel plated) Stainless steel 304 Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.

Mounting bracket Ass'y Mounting screws Controller model M3 x 0.5 LC1-1-N3 LC1-1B-N3 M5 x 0.8 LC1-1-N5 LC1-1B-N5 M3 LC1-1-L3 LC1-1B-L3 M5 LC1-1-L5 LC1-1B-L5 Note) This controller comes with either the T-nuts or T-brackets as accessories.

T-brackets T-nuts Model LC1-1-L5 (Weight: 16.0g) Model LC1-1-L3 (Weight: 15.5g) M (Weight: 10.0g) M5 M3 17.5 17.5 17.5 7.5 18 12 11 Model M 20 7.5 7.5 21 LC1-1-N3 M3 x 0.5 29 30 LC1-1-N5 M5 x 0.8 Controller Connectors These are connectors 'all halfpitch type' used for CN1 (control input/output) and CN2 (general purpose input/output).

Tap M5 thread on the brackets mounting positions at the installation side, and fix the ionizer body and brackets with M5 threads. M5 tap M5 threads 4. Adjust angle of the ionizer body to ensure proper static charge elimination, and fix it with detent threads (M5) of brackets.

9 23 55 53 28 M8 X 1.25 10 86 6.9 9.5 16 MM (N) M (NA) NN PA* PB PW Q QW RB RW S T U W X Y Z Bore size (mm) 12 M4 X 0.7 M8 X 1.0 6 8 27 30 60 80 85 26 RB0806 17.5 96 13 1 77 22 7.5 5 16 M5 X 0.8 M8 X 1.0 8 8 27 45 70 95 90 40 RB0806 15 103 13 2 92 22 7.5 5 20 M6 X 1 M10 X 1.0 10 10 29 60 100 120 105 46 RB1007 26 122 17 2 117 29.5 9 5.5 25 M6 X 1 M14 X 1.5 10 12 50 60 100 130 105 50 RB1411

Activated carbon filter Bracket B Bracket A Mounting screws Bracket mounting view Accessories Sold Separately/ International Standard Specific Product Precautions 22 AMK Series Dimensions AMK20 AMK30 AMK40 S N T J D M S N T U D J M U 2 x P 2 x P Q R Q R (Port size) (Port size) G B V C V C B IN OUT IN OUT Maintenance space A Maintenance space A E G AMK50 AMK60 D M J N T S U 2 x P R (Port size

Bore size NTJ-010A NTJ-006A 8 6 M3 x 0.5 2.4 5.5 6.4 5.5 6.5 M3 x 0.5 6 12.5 M4 x 0.7 3.2 7 8.1 7 8.5 M4 x 0.7 8 14.5 NTJ-015A 10 M5 x 0.8 4 8 9.2 10.5 M5 x 0.8 16.5 10 9 (mm) Standard C D E F B A J K L M N O P G H I Bore size 8 6 M2.5 x 0.45 13 7 7 10 9 19 3 5 4 9 3.5 8 7 5.3 24 M3 x 0.5 13 7 8 11 10 21 3 6 5 11 4.5 10 8 5.3 25 10 13.5 M3 x 0.5 7 8.5 11.5 10.5 22 3.2 6 6 12 5 11 8.5 5.6

U R(PT)1/8 M5 X 0.8 J\SP. 4;JOF~02 R(PT)I /4 Rc(PD1 /8 IIS'P530F:03 R(PT)318 Rc(PT)lIS 'ASi"!)30l"'lJ4 " R(PT)1!2 Rc(PT)1I4 ASP;l3OF:,FO~ RIPT)114 G(PF)1I8 I\Sps:ioFf;03' R(PT)318 G(PF)118 ),I'SPsJOF;;04: R(PT)1 /2 G{PF)1/4 A~P33!1F" 'l Il1 NPT1 /8 10-32UNF ,~Sp430FNO,?

C J G5-S Air-hydro Converter: CCT40 CV MVGQ 50 M32 x 2 Lube-plug CC Rc 1/4 Air port size RB J D-X 20Rc 1/4 Oil port size Data L Dimension (Effective oil level stroke) (mm) Effective oil level stroke (mm) 50 100 150 200 300 L 213.5 263.5 313.5 363.5 463.5 10-17-9 Valve Unit Series CCVS/CCVL How to Order CCV S 1 1 1 U1 Suffix S Single valve Valve unit size Unit for CC63 (Unit mounted to CCT63

C J G5-S Air-hydro Converter: CCT40 CV MVGQ 50 M32 x 2 Lube-plug CC Rc 1/4 Air port size RB J D-X 20Rc 1/4 Oil port size Data L Dimension (Effective oil level stroke) (mm) Effective oil level stroke (mm) 50 100 150 200 300 L 213.5 263.5 313.5 363.5 463.5 10-17-9 10 Valve Unit Series CCVS/CCVL How to Order CCV S 1 1 1 U1 Suffix S Single valve Valve unit size Unit for CC63 (Unit mounted to

mm2 30 M5 (Power supply) 50/60Hz (3 x AWG10) (Power supply) 3phase HRSH090-A-4020 AC460-480V HRSH090-W-401 x 14 mm2 (1 x AWG6) R14-5 60Hz (Grounding (Grounding cable) 3phase cable) 1: A specified earth leakage breaker is installed for option B [Earth leakage breaker] or option S [CE/UL] of each model.

HRZ x V x C x iT it m x C x (T0 Tt) it Q = = HRZD 1 x 300 x 4.186 x 103 x 12 900 = = 16744 [J/s] 16.7 [kW] m x C x (T0 Tt) it x 860 x V x 60 x C x iT it x 860 HRW Q = = Cooling capacity = Considering a safety factor of 20%, 16.7 [kW] x 1.2 = HECR 1 x 300 x 60 x 1.0 x 103 x 12 15 x 860 20 [kW] = HEC Thermo-chiller Q x t: Heat capacity [kJ] 16744 [W] = 16.7 [kW] Water bath 20C HEB Cooling

S, W, X, Y , Z, T, J, K Size Allowable kinetic energy [J] Adjustable range of rotation time safe in operation [s/90] Without air cushion With air cushion* 30 0.01 0.12 -X7* Heat resistant (100C) S, W, X, Y , Z, T, J, K 0.2 to 1 50 0.05 0.98 0.2 to 2 63 0.12 1.50 0.2 to 3 80 0.16 2.00 0.2 to 4 100 0.54 2.90 0.2 to 5 Cushion angle 35 -X16 Fluororubber seal S, W, X, Y , Z, T, J, K * -X7: Not

thread depth 3.5 Vacuum suction port 35 Note) 11-, 22-: Vacuum suction port 12-, 21-: Relief port ST 61+ST 15 49.5+ST 3.5 8 13 1 M5 x 0.8 x 4 L 4 16 14+ST 4.5 4.5 (Hexagon socket set screw) M8 x 1.25 x 8 L (Bolt holder) 1 40 45 45 3 3 330.2 330.2 330.2 42 20 8 8 6.5 counterbore depth 5.5 (Same on the opposite side) 3.4 through 2 x M3 x 0.5 through 3 3 6.5 45 45 M4 x 0.7 x 14.5 L (Hexagon

M N C D 4-O T Q 2-P E B S K L U W AA A I AP R X AB Y + Stroke J V Z + Stroke AC AD 8-AF AE For standard stroke (mm) Bore size (mm) Stroke range (mm) AC E D AF G AE AD AB AA N M F L K B J AP C H I A 20 25 32 40 50 75, 100, 125, 150, 200 M5 x 0.8 depth 10 16.5 92 60 9.5 depth 6 30 75 11 12 45 25 5.5 80 60 55 108 M8 x 1.25 depth 14 25 24 30 99 M6 x 1 depth 12 16.5 113 65 11 depth 8 30 85 13

A AL B B1 C D E F G H H1 J K KA M MM N P S ZZ 32 Up to 300 22 19.5 42 17 31 10 24 8 9 38 6 M5 x 0.8 5.5 8 8 M10 x 1.25 18 1/8 63 109 40 Up to 300 24 21 48 22 37 14 32 9 9 44 8 M5 x 0.8 8 12 8 M14 x 1.5 18 1/8 62 114 45 Up to 300 24 21 52 22 41 14 32 9 9 44 8 M5 x 0.8 8 12 8 M14 x 1.5 18 1/8 62 114 50 Up to 400 35 32 60 27 45 18 38 10 9 55 11 M6 x 1 7 16 11 M18 x 1.5 18 1/8 63 129 56 Up to

100 x 253 150 x 140 x 446 200 x 170 x 526 280 x 280 x 497 63 x 63 x 191 85 x 85 x 258 120 x 120 x 236 140 x 140 x 383 180 x 170 x 465 63 x 63 x 136 80 x 82 x 170 90 x 90 x 233 140 x 140 x 380 140 x 140 x 490 140 x 140 x 590 80 x 80 x 153 90 x 90 x 216 140 x 140 x 250 140 x 140 x 360 140 x 140 x 460 AFF4B AFF22B AFF37B AFF75B AM150 AM250 AM350 AM550 AM650 AMD150 AMD250 AMD350 AMD450 AMD550

Port 1(P) S K L M N B T Port 3(R) A G A Unit: mm Model A B C Fn Fd G J XLAV-16-2 40 108 38 30 17 41 XLAV-25-2 50 121 48 40 26 46 XLAV-40-2 65 171 66 55 41 54.5 XLAV-50-2 70 185 79 75 52 61 XLAV-63-2 88 212 100 87 95 70 80.5 XLAV-80-2 90 257 117 114 110 83 90.5 Model K L M N S T XLAV-16-2 17.2 10.2 3.6 3.6 M5 M5 XLAV-25-2 21.4 10.2 3.6 3.6 M5 M5 XLAV-40-2 33.9 10.2 3.6 3.6 M5 M5 XLAV-50-2

M10 x 1.25 14 +0.08 0 7.5 2 10 M12 x 1.25 16 11.5 3 14.5 M14 x 1.5 +0.08 0 Trunnion mounting taps for the width across flats NA are not attached to 80 and 100 types. 18 (mm) Bore size (mm) Stroke range (mm) 20 25 32 40 50 63 80 100 A AL B1 C D E F GA GB H H1 I J K KA MM 35 12 26 12 5 M4 x 0.7 depth 7 5 M8 x 1.25 Up to 200 14 13 8 15.5 2 18 12 6 40 12 31 12 6 5.5 M10 x 1.25 M5 x 0.8 depth