Products approved by CSA or UL standards are accepted in most states and governments beyond question.
prevent a pressure increase caused by exhausted air inside the control panel or temperature rise caused by the heat generated by the valve. 3.
MY1B m2 m3 Moment (Nm) MY1M M1 = F1 x L1 F1 M2 = F2 x L2 M3 = F3 x L3 F3 F2 MY1C L2 L1 L3 MY1H 4. Accuracy Mechanically jointed rodless cylinders do not guarantee traveling parallelism. When accuracy in traveling parallelism and intermediate stroke position is required, please contact SMC sales representatives.
Dynamic moment MG Va Calculation Example CX m Operating Conditions Cylinder: CYP32 Mounting: Horizontal wall mounting Maximum speed: U = 300 [mm/s] Load mass: m = 1 [kg] (excluding mass of arm section) L1 = 50 [mm] L2 = 50 [mm] D-X L2 L1 20Data Item Load factor n Note 1. Maximum load mass m 1 = m/mmax = 1/5 = 0.20 L2 Review m. L1 M2 = m g (L1 + B) 103 2.
Mep MXF L2 A4 Fig. (3) Workpiece Mounting Coefficient: K L3 A2 MXW Table mounting MXJ W Note) Static moment: Moment generated by gravity Dynamic moment: Moment generated by impact when colliding with stopper MXP Table (1) Maximum Allowable Kinetic Energy: Emax (J) MXY K = 1 1.0 End plate mounting Model Allowable kinetic energy Rubber bumper 0.027 0.055 0.11 0.16 MTS 0.7 MXF8 MXF12 MXF16 MXF20
Dynamic moment Va Calculation Example m Operating conditions Cylinder: CYV32 Mounting: Horizontal wall mounting Maximum speed: U = 300 [mm/s] Load mass: m = 1 [kg] (excluding mass of the arm section) L1 = 50 [mm] L2 = 50 [mm] L2 L1 Item Load factor n Note 1. Maximum load mass m 1 = m/m max = 1/5 = 0.20 L2 Review m. L1 2.
= 50 [mm] D-X L2 L1 20Data Item Load factor n Note 1.
Mep MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com L2 A4 Fig. (3) Workpiece Mounting Coefficient: K L3 A2 CX Table mounting DW Note) Static moment: Moment generated by gravity Dynamic moment: Moment generated by impact when colliding with stopper Graph (1) Allowable
(M12, 8 pins, plug) (Pitch) P = 20 25 Connector for input device connection (M12, 4 pins, socket) DIN rail 47 31 8 5.5 35 31 60 L2 L3 (L4) Position indicator LED 5 Marker: BN-WH (Made by Phoenix Contact) (Rail mounting pitch: 12.5) L1 46.9 44.2 EX500-IB1 EX500-IE3 EX500-IE3 EX500-IE3 EX500-IE3 EX500-IE3 EX500-IE3 EX500-IE3 EX500-IE3 32.2 (7.5) (PNP) VOLTAGE IP CODE 24VDC/60mA IP65 IP65 24VDC
Products approved by CSA or UL standards are accepted in most states and governments beyond question.
For standard installation, turn 15 to 30 using tool, after fastening by hand. Pay attention not to over torque the product.
element Drain cock D side Outlet for check Control unit n: Stations L Stations Formula 20n + 21 20n + 176 20n + 232.5 4 101 5 121 6 141 7 161 8 181 9 201 10 221 11 241 12 261 13 281 14 301 15 321 16 341 17 361 18 381 19 401 20 421 21 441 22 461 23 481 24 501 3 81 236 256 276 296 316 336 356 376 396 416 436 456 476 496 516 536 556 576 596 616 636 656 292.5 L1 L2 (MP) L2 (AP) 312.5 332.5
5 (R) port] 4 x 7 (For mounting) 1/8 (Pilot port: Upward) 30 (Pitch) P=33 VPA4 Breathing hole SYJA (Station n) (Station 1) 1/8 [Pilot port: Lateral (-P)] VZA VTA 76 53.5 29.5 VGA VPA Dimensions n: Stations 2 3 n L 10 9 8 7 6 5 4 357 VPA3 L1 L2 93 126 159 192 225 258 291 324 80 113 146 179 212 245 278 311 344 Type 21: VV5FA5-21-1-: Common exhaust L2 L1 17.5 20 15 3 P R R 66 2B 2B 2B 2B 2B
(VJA314) Air operated valve is controlled by external 3 port valve. External release is done directly from external 2 port valve. The following columns shall be filled in by SMC. Enter the ordering number in the table. Part no. Qty. Part no. Qty. Order no. Person in charge (Code no.) Section code 13-14-18 Date issued: 18 Photo copying this page is recommended.
812 796 853 837 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations Station n L1 L2 1573
DIN rail is prepared by customer. DIN rail is not suitable for port size F02 (G1/4).
This can be prevented by inserting a noise filter, such as a line noise filter and ferrite core, between the switch-mode power supply and the product, or by using a series power supply instead of a switch-mode power supply.
The NvJ3000 may be used as a N.C. or N.o. 3 way valve by plugging one ol the A, B ports. Be sure not to plug the exhaust ports.