5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 359.0/9.5 (at 20C)??1.00.29/0.33 (at 37/49 l/min, total lifting height 25/25 m)37/4940Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 359.0/9.5 (at 20C)??1.00.29/0.33 (at 37/49 l/min, total lifting height 25/25 m)37/4940Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 359.0/9.5 (at 20C)??1.00.29/0.33 (at 37/49 l/min, total lifting height 25/25 m)37/4940Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 359.0/9.5 (at 20C)??1.00.29/0.33 (at 37/49 l/min, total lifting height 25/25 m)37/4940Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 359.0/9.5 (at 20C)??1.00.29/0.33 (at 37/49 l/min, total lifting height 25/25 m)37/4940Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 359.0/9.5 (at 20C)??1.00.29/0.33 (at 37/49 l/min, total lifting height 25/25 m)37/4940Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 359.0/9.5 (at 20C)??1.00.29/0.33 (at 37/49 l/min, total lifting height 25/25 m)37/4940Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 3513.0/14.5 (at 20C)??1.00.28/0.31 (at 42/53 l/min, total lifting height 25/25 m)42/5360Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 3513.0/14.5 (at 20C)??1.00.28/0.31 (at 42/53 l/min, total lifting height 25/25 m)42/5360Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 3513.0/14.5 (at 20C)??1.00.28/0.31 (at 42/53 l/min, total lifting height 25/25 m)42/5360Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
.: 4, 6, 8, 10, 12, Applicable fittings include: KQ, KJ, KF, KFG, and M/MS, Tubing colors include: black, white, red, blue, yellow green, Maximum operating pressure: 20C = 0.8 MPa and 60C = 0.4 MPa, TUBING, WEAR RESISTANT, CONNECTORS, TUZ WEAR RESISTANT TUBING, FX, TUZ 6MM, .86112 lb, ModelTubing O.D. (mm)Tubing I.D. (mm)--TUZ060464--
W (due to an increase in the heat generation of the pump) Note 1) -MT: Applicable to deionized water piping + High pressure pump Note 2) The capacity at the thermo-chiller outlet when the circulating fluid temperature is 20C. Note 3) Required minimum flow rate for cooling capacity or maintaining the temperature stability. Note 4) Cooling capacity will decrease as pump power increases.
W (due to an increase in the heat generation of the pump) Note 1) -MT: Applicable to deionized water piping + High pressure pump Note 2) The capacity at the thermo-chiller outlet when the circulating fluid temperature is 20C. Note 3) Required minimum flow rate for cooling capacity or maintaining the temperature stability. Note 4) Cooling capacity will decrease as pump power increases.
Installation environment and power supply are within specification range and stable. 6 The capacity at the thermo-chiller outlet when the circulating fluid temp. is 20C. 7 Fluid flow to maintain the cooling capacity and the temperature stability.
Installation environment and power supply are within specification range and stable. 6 The capacity at the thermo-chiller outlet when the circulating fluid temp. is 20C. 7 Fluid flow to maintain the cooling capacity and the temperature stability.
Please contact us for the latest version.sales@ocaire.com, GRIPPER PARALLEL TYPE, ACTUATOR, MHZ2 GRIPPER, PARALLEL, HT, 20MM MHZ2, .83591 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2) Mass (g) Gripping force per finger Effective value (N) ExternalInternalSingle actingNormally closedMHZ2-20C(N)20?5710240
Please contact us for the latest version.sales@ocaire.com, GRIPPER PARALLEL TYPE, ACTUATOR, MHZ2 GRIPPER, PARALLEL, HT, 20MM MHZ2, .88184 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2) Mass (g) Gripping force per finger Effective value (N) ExternalInternalSingle actingNormally closedMHZ2-20C(N)20?5710240
40mm, Double acting and Single acting available, Auto switch capable, Improved rigidity of guide rail, GRIPPER PARALLEL TYPE, ACTUATOR, MHZ2 GRIPPER, PARALLEL, HT, 20MM MHZ2, .80836 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2) Mass (g) Gripping force per finger Effective value (N) ExternalInternalSingle actingNormally closedMHZ2-20C