Magnet: None, Mounting: Front Nose, Bore Size: 40mm, Stroke: 100mm, Action: Spring Extend, Switch Mounting: -, Stainless Steel: -
Magnet: None, Mounting: Front Nose In-line, Bore Size: 40mm, Stroke: 100mm, Action: Spring Extend, Switch Mounting: -, Stainless Steel: -
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 100, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~80, Operating Pressure(MPa): 0.05~1.0, Specification: Without magnet, Support bracket: None
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~80, Operating Pressure(MPa): 0.05~1.0, Specification: Without magnet, Support bracket: None
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 100, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~80, Operating Pressure(MPa): 0.05~1.0, Specification: Without magnet, Support bracket: None
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~80, Operating Pressure(MPa): 0.05~1.0, Specification: Without magnet, Support bracket: None
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnet: Built-in Magnet, Series: Standard, Head Cover Type: Double End Boss-cut, Bore Size: 32mm, Stroke: 100mm, Action: Single Acting, Spring Extend, Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: Rail Mounting
Magnet: D (Built-in), Series: 85 (Standard), Head Cover Type: N (Basic Integrated Clevis), Bore Size: 25mm, Stroke: 100mm, Action: T (Spring Extend), Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: B (Band)
Magnet: D (Built-in), Series: 85 (Standard), Head Cover Type: N (Basic Integrated Clevis), Bore Size: 16mm, Stroke: 100mm, Action: T (Spring Extend), Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: B (Band)
Magnet: D (Built-in), Series: 85 (Standard), Head Cover Type: F (Boss Cut), Bore Size: 20mm, Stroke: 100mm, Action: T (Spring Extend), Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: A (Rail)
Magnet: D (Built-in), Series: 85 (Standard), Head Cover Type: N (Basic Integrated Clevis), Bore Size: 20mm, Stroke: 100mm, Action: T (Spring Extend), Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: B (Band)
Magnet: None, Mounting: Basic Style, Bore Size: 40mm, Piping: Screw-in, Stroke: 100mm, Action: Single Acting Spring Extend, Valve Voltage: 110VAC, Electrical Entry: Grommet, Light & Surge Suppressor: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Single Clevis, Bore Size: 20mm, Piping: Screw-in, Stroke: 100mm, Action: Single Acting Spring Extend, Valve Voltage: 24VDC, Electrical Entry: DIN Terminal, Light & Surge Suppressor: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 100mm, Action: Single Acting Spring Extend, Head Cover Port: 90° to Axis (or No Port for Spring Extend), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Made-to-Order: -
Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 100mm, Action: Single Acting Spring Extend, Head Cover Port: 90° to Axis (or No Port for Spring Extend), Auto Switch: A--With Switch Rail, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -
Magnet: Built-in, Mounting: Front Flange, Bore Size: 16mm, Stroke: 100mm, Action: Single Acting Spring Extend, Head Cover Port: 90° to Axis (or No Port for Spring Extend), Auto Switch: Band Type Switch, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -
Magnet: Built-in, Mounting: Axial Foot, Bore Size: 16mm, Stroke: 100mm, Action: Single Acting Spring Extend, Head Cover Port: 90° to Axis (or No Port for Spring Extend), Auto Switch: J79W--Solid State, 2-color Indication, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -
Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 100mm, Action: Single Acting Spring Extend, Head Cover Port: 90° to Axis (or No Port for Spring Extend), Auto Switch: Band Type Switch, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -
Magnet: Built-in, Mounting: Axial Foot, Bore Size: 16mm, Stroke: 100mm, Action: Single Acting Spring Extend, Head Cover Port: 90° to Axis (or No Port for Spring Extend), Auto Switch: F7PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -