SMC Corporation of America
Elite Part Number Search
Search Results "PSE577-02-28"

No Thread IMPERIAL Code : Thread Form 00 : None (No reduction in METRIC Code : Thread Form METRIC Code : Thread Form Code : Thread Form 27 : 3/4-10 60 : M3 x 0.35 88 : M14 x 1.5 piston rod diameter) 28 : 3/4-16 61 : M3 x 0.5 89 : M20 x 1.5 01 : 2-56 29 : 7/8-9 62 : M4 x 0.5 90 : M12 x 1.25 02 : 2-64 30 : 7/8-14 63 : M4 x 0.7 91 : M42 x 1.5 03 : 4-40 31 : 1-8 64 : M5 x 0.5 92 : M24 x 3.0 04

(Example) CUJ-M3 x 27l A A C B B D Axial mounting style Lateral mounting style Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Without Auto Switch For Axial Mounting For Lateral Mounting B 21 23 25 27 22 24 26 28 33 22 24 26 28 33 38 22 24 26 28 33 38 Model Mounting

Note 4) Energization on A (set) side generates vacuum and energization on B (reset) side stops generation of vacuum. 28 - Doc. no. ZB-OM00201-B How to operate the supply valve of the latching type Latching type refers to a solenoid with a self holding mechanism.

assembly ZK2-CH 2 04 -A Connector type Applicable stations 1 D-sub connector (25 pins) 02 For 2 stations manifold 2 Flat ribbon cable connector (26 pins) 04 For 4 stations manifold 06 For 6 stations manifold 08 For 8 stations manifold 10 For 10 stations manifold -43No.

ZK2-OM00201 Manifold ZZK2 04 A 1 L 00 00 (1) (2) (3) (4) (5) (6) Remains blank when no potion is selected. (1) Number of stations Note 1) Symbol Stations 01 1 station 02 2 stations 10 10 stations Note 1) In the case of an ejector, for an adequate performance, the number of stations when operated simultaneously depends on the nozzle diameter.

BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon receipt of order.

L dimension 19 248 18 235.5 17 223 16 210.5 15 198 14 185.5 13 173 12 160.5 11 148 No. 20 260.5 L dimension 30 385.5 29 373 28 360.5 27 348 26 335.5 25 323 24 310.5 23 298 22 285.5 21 273 No. Blanking plate with 2 screws and gasket L dimension 39 498 38 485.5 37 473 36 460.5 35 448 34 435.5 33 423 32 410.5 31 398 No. 40 510.5 L dimension 4-12-16

Stations Stasions 3 2 1 Dside Uside 02 2 stations VVQ1000-10A-2 20 20 stations Port size and thread 01N 01T 01F M5, Rc(PT)1/8 NPT1/8 NPTF1/8 G(PF)1/8 Only thread port size 1/8 style (2U type, P/E port) has choice of thread.

(TB-3CB) TG.1 TG.2 36' w )i 28 d!65 h TK-2 Tube Cutter (1mn llb n9 or less) TK-3 Tub Cuire.

Stations U side D side 2 stations 02 VVQ1000-10A-2 Stations4321 20 stations 20 Port size and thread M5, Rc 1/8 NPT 1/8 NPTF 1/8 PF 1/8 Nil 01N 01T 01F Only thread port size 1/8 type, (Type 2U, P/E port) has choice of thread.

Clear Water (as Circulating Water) Quality Standards The Japan Refrigeration and Air Conditioning Industry Association JRA GL-02-1994 Cooling water system Circulating type Supply water Influence Item Unit Standard value Corrosion Scale generation p p p p p p pH (at 77F (25C)) 6.0 to 8.0 100to 300 Electrical conductivity (77F) [S/cm] Standard item Reference item Chloride ion (Cl) [mg/L]

Stations U side D side 2 stations 02 VVQ1000-10A-2 Stations4321 20 stations 20 Port size and thread M5, Rc 1/8 NPT 1/8 NPTF 1/8 PF 1/8 Nil 01N 01T 01F Only thread port size 1/8 type, (Type 2U, P/E port) has choice of thread.

For the specifications of D-M9, please refer to SMC Information '02-E500. AC DC Auto switch model Lead wire (m) Load voltage Indicator Wiring (Output) Special function Type Electrical entry Pre-wired connector Applicable load 3 (L) 5 (Z) 0.5 (Nil) Perpendicular In-line 3-wire (Equiv.

Note 3) If clear water is used, use water that conforms to Water Quality Standards of the Japan Refrigeration and Air Conditioning Industrial Association (JRA GL-02-1994 cooling water system circulating type make-up water).

Connection circuit (POWER connector) 0.8-1.0 26-24 0.14-0.2 ZS-28-C Wiring of the IZS40 e-con is adopted for the connector of the IZS40. Connector with cable or without cable may be selected when placing an order for the power supply cable. When only an e-con is required, place an order for it as a part.

Caution REC25 101110-AS2001F-06-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC32 101110-AS3001F-08-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC40 101110-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 2. Speed control is possible with meter-in and meter-out types of speed controllers.

Accessory (Option)/For AFF2B to AFF75B Applicable model Bracket assembly With cap bolt and spring washer AFF2B AFF4B AFF8B AFF11B AFF22B AFF37B AFF75B BM51 BM52 BM53 BM54 BM55 BM56 BM57 Accessory (Option)/For AFF75A to AFF220A AFF75A AFF125A AD402-03-2 G46-15-02 AFF150A AFF220A Applicable model Auto drain (2 pcs. each) Pressure gauge (2 pcs. each) Companion flange (2 pcs. each) Anchor bolt

(Including band and screw) Operating Range Bore size (mm) Bore size (mm) Auto switch model Auto switch model 20 25 32 40 50 20 25 32 40 50 D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 D-B7/B80 BMA2 -025 BMA2 -032 BMA2 -040 BMA2 -050 BMA2 -020 10 8 10 9 10 D-B73C/B80C D-C7/C80 BA -32 BA -04 BA -05 BA -01 BA -02 10 8 10 9 10 D-C73C/C80C D-B5/B64 BM1 -01 BM1 -02 BM1 -32 BM1 -04 BM1 -05 10 8

BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon receipt of order.

Remarks Power supply/output cable ZS-26-L Length 2 m For PF2A5##, PF2W5##, PF3W5## Connector for sensor lead wire (e-con) ZS-28-CA-4 1 pc., Finished outside diameter: 1.15 to 1.35 Cover colour: Blue For PF2D5## Connector for sensor lead wire (e-con) ZS-28-CA-2 1 pc., Finished outside diameter: 0.9 to 1.0 Cover colour: Red Panel mount adapter ZS-26-B With set screw M3 x 8L (2 pcs.) and waterproof