A Normally OFF detection (1) (2) B Normally ON detection Adjust the switch position according to load and speed. (mm) A 2 2.5 4 5 5.5 10 B Model MXS6 MXS8 MXS12 MXS16 MXS20 MXS25 3 86

MGC MGF CY1 q B MY1 Normally ON w * Adjust the switch position according to load and speed.

When sum of load rate does not exceed 1, it is possible to use. n=1+2+3 1 < = < = 47 MXS Series Air Slide Table How To Select Allowable load: W(N) Fig.1 Overhung: Ln(mm), Correction value for moment center distance An (mm) Fig.2 Pitch moment Yaw moment Roll moment W My Mp Mr W W W Static moment Kinetic moment L1 A1 L3 A5 L2 A3 W Mp Mr My W W L3 A6 W L1 A2 L2 A4 W Mey Mep L2 A4 A2 L3 Work

V IDF100F V IDF125F V IDF150F B 1-3 IDF100150F 1 4 IDX-OM-U021 1 3.6 5.2 (IDF100F, 125F) R OFF 5.2 L1 L2 L3 M5 9.5mm 3.5mm 2 1,2 3,4 5,6 L1,L2,L3 PE: L1 L2 L3 PE 1 2 3 4 5 6 M4 9.5mm 5.5mm 2 M3 6.5mm 1.25mm 2 1-3 IDF100150F 1 5 IDX-OM-U021 1 3.6 5.2 5.2 (IDF150F) R OFF L1 L2 L3 M5 9.5mm 3.5mm 2 1,2 3,4 5,6 L1,L2,L3 PE: L1 L2 L3 PE 1 2 3 4 5 6 M4 9.5mm 5.5mm

Lead Series Lead (Including Pn20E Pn210 symbol pulley ratio) A 12 65536 750 LEY25/LEYG25 B 6 375 LEY25D/LEYG25D C 3 131072 375 A 20 65536 1250 LEY32/LEYG32 B 10 625 LEY63D C 5 131072 625 A 16 1000 LEY B 8 500 LEY32D/LEYG32D C 4 250 65536 A 20 1250 B 10 625 C 5 131072 625 LEY63 5(2.86) L 229376 625 (Pulley ratio 4/7) H 20 1250 LEFS25 A 12 750 B 6 375 H 24 1500 LEFS32 A 16 1000 B 8 500 LEF

L2 [mm] L2 [mm] L2 [mm] 600 600 600 Y 400 400 400 Mer m 200 200 200 0 0 0 0 5 10 15 20 25 30 35 0 10 20 30 40 50 0 10 20 30 40 50 60 70 Work load [kg] Work load [kg] Work load [kg] 1000 1000 1000 800 800 800 Mep L3 [mm] L3 [mm] L3 [mm] m 600 600 600 L3 Z 400 400 400 200 200 200 0 0 0 0 10 20 30 40 50 60 70 0 10 20 30 40 50 0 5 10 15 20 25 30 35 Work load [kg] Work load [kg] Work load [kg

-LD Piping port P Operating direction A 7 Piping port P Operating direction B W K G With switch rail Q + Stroke Z + Stroke Piping port P (plug) Operating direction B HS CR HR Plug 22 8 Piping port P Operating direction B Piping port P (plug) Operating direction B 8 Piping port P Operating direction A 16 19.5 16 Plug REBR15 REBR15 (mm) A B C CB CR D F G GP GW H HA HB HC HP HR HS HT Model REBR15

Switch operating range Stroke (mm) 20 41 29 47 35 Type 25 46.5 34.5 30 55 43 10 31 19 15 36.5 24.5 A B A B A B MXP10 Auto switch MXP12 3 Screwdriver (Grip diameter 5 to 6mm) MXP16 2 Color indication solid state switch D-F9BW(V), D-F9NW(V), D-F9PW(V) mm Switch operating range Stroke (mm) 20 42 28 48 34 Type 25 47.5 33.5 30 56 46 10 32 18 15 37.5 23.5 A B A B A B MXP10 MXP12

P1, L2 T1 S/S . P1, L4 T2 S/S . P1, L4 T3 S/S . P1, L4 T4 S/S . P1, L4 T6 S/S . P1, L4 RT3-1-1 S/S . P2, L5 RT3-3-1 S/S . P2, L5 RT3-1-3 S/S . P2, L5 RT1-3-1 S/S . P2, L5 X1 S/S . P3, L10 1 2 1 2 1/2 B Thd D A Thd C Hole Dia. Stainless Steel Threaded Parts Page & Part No. Line No. Page & Part No. Line No. D Line No.

d L2 d M M D1 D1 D2 D2 L6 L6 L3 L4 AS H H ASP (Width across flats) (Width across flats) ASN D3 D3 AQ A1 A1 ASV L5 L5 A2 A2 AK ASS T T ASR ASF Model T H D1 D2 D3 L1 L2 L6 A2 M L5 A1 Weight (g) Note 5) MAX.

A B A B 54 MXY6 34 MXH 59 5 MXY8 39 MXU 67 MXY12 47 MXS Solid State Auto Switch D-M9B(V), D-M9N(V), D-M9P(V) Lead wire entries inside MXQ (mm) B B Model Mounting Auto switch operating range MXF A B A B A B 50 MXY6 3 38 MXW 55 MXY8 3.5 43 MXJ 63 MXY12 3 51 MXP Lead wire entries parallel 2-Color Display Solid State Auto Switch D-M9BW(V), D-M9NW(V), D-M9PW MXY (mm) B A Model Mounting Auto switch

A B A B 54 MXY6 34 59 5 MXY8 MX 39 67 MXY12 MTS 47 MY Solid State Switch D-M9B(V), D-M9N(V), D-M9P(V) Lead wire entries inside (mm) B B CY Model Mounting Switch operating range A B A B A B 50 MXY6 2 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 38 55 MXY8 2.5

Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -37No.PS-OMY0007-A [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.

L4 Weight (g) L2 L3 D1 D2 L1 D3 A Part No.

Spatter Cover 2: KR (Applicable tube: FR soft nylon, FR double layer) Applicable fitting size Model Installed L1 L2 D KR-08C1 KR-06C1 6 12.8 15 18 20 KR-10C1 KR-12C1 18 13.7 20 15.7 22 17.2 22 17.2 8 10 12 One-touch fitting How to install One-touch fitting Construction of spatter cover Install with matching A and B parts. 15-3-5

time of pressure in the cylinder Body (Red) Residual pressure release push button (Red) VCHC D With One-touch fitting without a push button guard Release button (Blue) Release button (Blue) ASR ASQ D L1 Q B A D 8 4.2 Applicable tubing W (mm) M M L2 L2 Applicable tubing Weight (g) Model Applicable tubing O.D. 6 8 10 12 D L1 L2 Q W M KEB06 KEB08 KEB10 KEB12 12.8 15.2 18.5 20.9 25 27 27.7 29

Dynamic moment Me3 We W L2 Review Me3. = 1/3 14.7 (50 + 27) 103 = 0.38 [Nm] 3a = Me3/Me3 max = 0.38/3 = 0.13 Central axis of guide A Me1 W We Me1 = 1/3 We(L1 + B) 103 = 1/3 14.7 (50 + 48) 103 L1 B = 0.48 [Nm] 3b = Me1/Me1 max = 0.48/3 = 0.16 Review Me1.