, 75, 100, 125, 150, 200 201 to 350 301 to 400 301 to 450 301 to 800 D-C7/C8 D-B5/B6 D-H7 D-G5NTL 1500 10 mm 15 mm 25, 50, 75, 100, 125, 150, 200, 250, 300 D-B59W 15 mm 20 mm Note 1) Intermediate strokes other than the above are produced upon receipt of order.
Storage Service life cycles/Discharge per cycle (reference) Series Diaphragm material Discharge per cycle PTFE NBR Approx. 40ml PA3000 automatically operated type 100 million cycles 50 million cycles Approx. 100ml PA5000 automatically operated type 50 million cycles 50 million cycles Approx. 22ml PA3000 air operated type 50 million cycles In case of long term storage after use with water
/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other VC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other Nil S Z None With surge voltage suppressor With light/surge voltage suppressor With indicator light Option VDW L Light/Surge voltage suppressor Nil Z VQ Except 12 VDC, 240 VAC, other voltages
Between external terminals and case 1000V AC 50/60Hz for 1 min.
to 600 Accumulated pulse output wiring examples NPN 2 output type LFElAlll NPN + Analog output type LFElClll/LFElDlll Max. 28 V, 80 mA Black OUT1 Load White OUT2 (LFE A only) Load 0 V or Blue DC () 50 ms 50 ms PNP 2 output type LFElBlll Brown DC (+) Black OUT1 Max. 80 mA Load White OUT2 0 V or Load 50 ms 50 ms * When accumulated pulse output is selected, the indicator light is turned off
10.00 1000 1000 0 0 0 0.5 2 INC 50 10.00 1000 1000 0 0 0 0.5 2 3 INC 50 10.00 1000 1000 0 0 0 0.5 4 INC 50 10.00 1000 1000 0 0 0 0.5 57 No.SFOD-OMT0009CN-B () ... ...
type) Displacement m Displacement m 200 200 150 150 130 120 50 50 MSZA30A (High precision type) MSZA50A(High precision type) D70 60 50 40 30 20 10 0 120 100 80 60 40 20 0 Load N Load N 291 Rotary Table Air Consumption Air consumption is the volume of air which is expended by the rotary tables reciprocal operation inside the actuator and in the piping between the actuator and the switching
Standard Stroke (mm) Manufacturable stroke range Model Standard strokes CXSJ6 CXSJ10 CXSJ15 CXSJ20, 25, 32 60 to 100 10, 20, 30, 40, 50 80 to 150 10, 20, 30, 40, 50, 75 110 to 150 10, 20, 30, 40, 50, 75, 100 110 to 200 Strokes beyond the standard stroke range are available as a special order.
Standard Stroke (mm) Manufacturable stroke range Model Standard strokes CXSJ6 CXSJ10 CXSJ15 CXSJ20, 25, 32 60 to 100 10, 20, 30, 40, 50 80 to 150 10, 20, 30, 40, 50, 75 110 to 150 10, 20, 30, 40, 50, 75, 100 110 to 200 Strokes beyond the standard stroke range are available as a special order.
(kg) Load weight m (kg) Load weight m (kg) 30 30 20 -X 20 20 MGF40 MGF40 20MGF40 MGF40 10 10 10 MGF40 Data MGF40 10 5 4 3 5 4 3 2 2 5 5 1 10 20 30 40 50 100 200 300 400 1 5 4 10 20 30 40 50 100 200 300 400 5 10 50 100 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) l = 200 mm l = 300 mm Graph (3) Graph (4) v = 150 mm/s or less v = 200 mm/s or less Graph
Note 1) Note 2) Maximum available stroke (mm) Bore size (mm) 20 25 32 40 Standard stroke (mm) Model Long stroke (mm) 1 pc. 201 to 350 301 to 400 301 to 450 301 to 800 25, 50, 75, 100, 125, 150, 200 D-C7, C8 D-B5, B6 D-H7 D-G5N 15mm 10mm 1500 25, 50, 75, 100, 125, 150, 200, 250, 300 20mm 20mm 15mm 10mm D-B59W D-H7LF Note 1) Intermediate strokes other than the above are produced upon receipt
5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75, 100 56.5 49.5 10 to 50 48.5 40.5 11 depth 8 50 58.5 50.5 15 20 64 10.5 M10 x 1.5 86 7 17 8 50 6.6 1/4 10.5 80 41 19 75, 100 58.5 50.5 6 Series CQ2Y Mounting bracket dimensions are the same as those of the anti-lateral load type of Series CQ2S.
Standard stroke (mm) 10, 20, 30, 40, 50 10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 75 Bore size (mm) Nil S 6 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 75, 80, 90, 100 15, 20, 25, 32 Auto switch type Nil Without auto switch (built-in magnet) Note) Refer to the table below for auto switch part numbers. Applicable auto switches Load voltage Auto switch part no.
Use a fluid with a kinematic viscosity of 50 mm2/s or less.
Maximum Allowable Load MY3A, MY3B/m1 MY3A, MY3B/m2 MY3A, MY3B/m3 200 50 40 30 100 100 50 40 20 30 50 40 10 20 30 63 63 5 4 20 10 Load weight kg Load weight kg Load weight kg 63 3 40 10 40 5 4 2 3 25 5 4 1 25 40 2 3 25 0.5 0.4 16 2 1 16 0.3 16 1 0.2 0.5 0.1 0.5 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 MY3B max. MY3A max. MY3B max.
Standard Strokes Bore size [mm] Standard stroke [mm] *1 20 25, 50, 75, 100, 125, 150, 200, 250, 300 25 32 40 *1 Intermediate strokes not listed above are produced upon receipt of order. The minimum stroke is 25 mm. Mounting Brackets/Part No.
, 75, 100 54 M6 x 1.0 42 12 12(11.8) 45 8.5 M6 x 1.0 7 60 4.5 10 12 34 5.5 9 23 10 49.5 7 30 10 to 50, 75, 100 60.5 M6 x 1.0 48.5 13 16(15.8) 52 8.5 M8 x 1.25 7 69 5 14 12 40 5.5 9 26 10 57 10 40 10 to 50, 75, 100 62 M8 x 1.25 50 13 16(15.8) 64 12 M8 x 1.25 8 86 7 14 12 50 6.6 11 26 14 71 10 Note) Figures in ( ) are the dimensions for applying a wrench.
Note 1) Note 2) Maximum available stroke (mm) Bore size (mm) 20 25 32 40 Standard stroke (mm) Model Long stroke (mm) 1 pc. 201 to 350 301 to 400 301 to 450 301 to 800 25, 50, 75, 100, 125, 150, 200 D-C7, C8 D-B5, B6 D-H7 D-G5N 10mm 15mm 1500 25, 50, 75, 100, 125, 150, 200, 250, 300 15mm 10mm 20mm 20mm D-B59W D-H7LF Note 1) Intermediate strokes other than the above are produced upon receipt
Max. operating frequency 10 Hz Lubrication Manual override Non-locking push type Mounting orientation Unrestricted 150/50 m/s2 Impact/Vibration resistance (2) Dustproof Enclosure Grommet, Conduit, Conduit terminal, DIN terminal 100, 200, 110 , 220 , 240 Electrical entry DC AC (50/60 Hz) Coil rated voltage (V) 24, 12 15 to +10% of rated voltage 19 VA (50 Hz), 16 VA (60 Hz) 11 VA (50 Hz),
K M H D Plug Insertion Force in Pressurized Condition MS Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Insertion Force of Series KK T 350 300 VMG 250 Insertion force N Series KK6 200 Series KK4 150 100 Series KK3 Series KK2 50 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8