Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300/20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 300/20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Mounting: Front Flange, Bore Size: 40mm, Thread: Rc, Full Stroke: 300mm, First Stroke: 20mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Mounting: Front Flange, Bore Size: 50mm, Thread: Rc, Full Stroke: 300mm, First Stroke: 20mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Mounting: Front Flange, Bore Size: 63mm, Thread: Rc, Full Stroke: 300mm, First Stroke: 20mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Mounting: Front Flange, Bore Size: 50mm, Thread: NPT Thread, Full Stroke: 300mm, First Stroke: 20mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Valve stations 02 2 stations VK A port size (Base mounted) 20 20 stations VZ Max. 20 01 02 common exhaust/individual exhaust 1 8 individual exhaust 1 4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Please indicate manifold base type, applicable manifold valve
Flow rate characteristics Conditions: Upstream pressure 2.0MPa ARX20-01 ARX20-02 0.90 0.80 0.90 0.80 Downstream pressure MPa Downstream pressure MPa 0.70 0.70 0.60 0.60 0.50 0.50 0.40 0.40 0.30 0.30 0.20 0.20 0.10 0.10 0 0 100 200 300 400 500 600 700 800 900 1000 0 0 100 200 300 400 500 600 700 800 900 1000 Flow rate l/min(ANR) Flow rate l/min(ANR) ARX21-01 ARX21-02 0.35 0.35 0.30 0.30
Dead volume LVM11: 11 l or less LVM1R, LVM11: 20 l or less The dead volume enclosed by the body and the diaphragm Valve width ( ): 13 mm 2 port 3 port Valve width 9.5 mm (LVM090), 20 mm (LVM200) are also available.
change coils Clip design makes coil replacement easy Internal rectifier circuit (AC) AC/DC switchover is possible by simply changing the coil Reduced noise Incombustible molded coil material Conforms to UL94 V-0 Note) For Class B coil Coil size and weight reduced New compact coil reduces the overall size & weight of the valve Threaded assembly Simplifies maintenance Volume 15% Weight 20%
Caution One-touch fitting Dimensions VDW30-G--P7 / P7 Quick Fastener VDW40-G--P10 / P10 Quick Fastener 30 36 Approx. 300 21 23 32 18 20 27 Approx. 300 56 48 10 9 P7 1 (IN) port P7 2 (OUT) port 50 21 P10 1 (IN) port P10 2 (OUT) port 56 VDW40-5G--P10--N VDW30-5G--P7--N 16 12 2 x M3 x 0.5 thread depth 4 2 x M3 x 0.5 thread depth 5 Male Quick Fastener Dimensions Quick Fastener Clip Dimensions
Dead volume LVM11: 11 l or less LVM1R, LVM11: 20 l or less The dead volume enclosed by the body and the diaphragm Valve width ( ): 13 mm 2 port 3 port Valve width 9.5 mm (LVM090), 20 mm (LVM200) are also available.
H C37 3/4 20 J Stainless steel D 200 VAC E 230 VAC 6 25A N.C.
Refer to How to Order for standard specifications on pages 14-20-3, 16, 23, and 31.
20 SUP=0.2MPa SUP=0.2MPa 10 10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min 1m = 3.28ft 1l/min = 0.035SCFM Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
mA Maximum load impedance: 300 (12 VDC), 600 (24 VDC) Minimum load impedance: 50 PSE304 PNP open collector output (2 outputs), Max. 80 mA, residual voltage 1 V or less Analog output: 4 to 20 mA Maximum load impedance: 300 (12 VDC), 600 (24 VDC) Minimum load impedance: 50 DC(+) DC(+) (Brown) (Brown) Analog output Load Analog output (Gray) (Gray) + + Load OUT1 OUT1 12 to 24 VDC 12 to
6) 4 to 20 mA Accuracy: 2% F.S.or less, Max. load impedance: 300 or less with 12 VDC, 600 or less with 24 VDC output Power supply voltage 12 to 24 VDC 10% Current consumption 20 mA or less (without load) Enclosure IP65 Environmental resistance Operating temperature range Operating: 0 to 50C, Stored: 25 to 85C in stock (with no condensation and freezing) Voltage resistance 1000 VAC for
Description Material 40 NLP-40A PDU-16Z PSD-22 x 16 P44 DSM-20 CA40-1606 CA40-1601 P3 50 NLP-50A PDU-20Z PSD-27 x 20 P50 DSM-25 CA63-1608 CA50-1602 P3 63 NLP-63A PDU-20Z PSD-27 x 20 P60 DSM-25 CA63-1608 CA63-1603 P3 100 NLP-100A PDU-30Z PSD-38 x 30 P90 DSM-35 CA100-1610 CA100-1605 P5 Piston seal Rod seal A Rod seal B Brake piston seal Cushion seal Piston gasket Tube gasket Cushion valve seal
Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM, EPDM Model/Rated Flow Rate Model Port size Note 2) INLET OUTLET Rated flow rate (L/min) FH990-04 FH990-06 FH990-08 FH990-10 FH990-12 FH990-16 FH991-20 FH991-24 FH991-28 FH991-32 1B 1/2B 20 1B 3/4B 50 1 1/2B 1B 100 1 1/2B 1 1/4B 150 2B 1 1/2B 200 2B 2B 300 2 1/2B 2 1/2B 450 3B 3B 600 3 1/2B 3 1/2B 750 4B 4B 900 Note 2) Both flange
AS121FG-M5 AS231FG-01 R(PT) 1/8 20, 25, 32 AS221FG-01 AS231FG-02 R(PT) 1/4 20, 25, 32, 40 AS221FG-02 AS331FG-02 R(PT) 1/4 40, 50, 63 AS321FG-02 AS331FG-03 R(PT) 3/8 40, 50, 63 AS321FG-03 AS431FG-04 R(PT) 1/2 63, 80, 100 AS421FG-04 AS131FG-U10/32 10-32UNF 6, 10, 16, 20 AS121FG-U10/32 AS231FG-N01 NPT1/8 20, 25, 32 AS221FG-N01 Elbow type AS231FG-N02 NPT1/4 20, 25, 32, 40 AS221FG-N02 AS331FG-N02