SMC Corporation of America
Elite Part Number Search
Search Results "RZQL32TF-75-20"

H 28 30 36 44 54 E 22 21 26 F 45 55 58 65 76 G 33 42 44 50 61 D 34 46 63 67 78 A 59 78 107 110 134 B 20 29 39 42 53 C 40 53 70 75 90 I 45 55 63 69 81 Model Piping port VHS20 VHS30 VHS40 VHS40-06 VHS50 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1938 Series VHS20/30/40/50 Specific Product Precautions Be sure to read before handling.

Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. q Symbol Description Body size 20 40 60 30 Nil K Note 1) Without backflow function With backflow function With backflow function w + Nil N Note 2) F Note 3) Thread type Rc NPT G e + 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 Port size r + Nil B Note 5) H Note 4) a Without mounting option

Registration of dummy Remote 75 6. Wireless system configuration example 76 6.1. Flow chart for using the wireless system (Refer to Step 2) 76 6.2. System Construction Example 77 6.3.

30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMS0001-B 6.

25 30 ( 30 10 XL-OMY0001 5 5-1 1 , SUS304 8 4 SUS304 10 , SUS316L 7 5 A6063 2 1 6 SUS304 3 2 9 2 SUS304 SUS304 11 XL-OMY0001 5-2 C E E E KF K Fd Fn C D H B A G A mm A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257

Single Axis Electric Actuator Series LJ1 (AC Servomotor) Maximum speed mm/s Work load kg Positioning repeatability mm Clean room Dust seal Series Guide type Lead screw Brake 5 300 0.1 Horizontal mount specification Slider guide Series LJ1 300 Slide screw 0.1 500 0.1 1 0 Ground ball screw 0.02 High rigidity direct acting guide 600 Rolled ball screw 0.05 1 5 0.1 500 Slide screw 20

Standard strokes (mm) Bore sizes (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 32, 40 50, 63 80, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Example) For CQ2XB40-57D, an 18mm spacer is installed inside a standard stroke CQ2XB40-75D cylinder. Specific Product Precautions Be sure to read before handling. Refer to pages 15 to 24 for safety instructions and precautions.

Single Axis Electric Actuator Series LJ1 (AC Servomotor) Maximum Work Positioning Clean Dust speed Series Guide type load Lead screw Brake repeatability room seal mm/s kg mm 5 300 0.1 Horizontal mount specification Slider guide Series LJ1 300 Slide screw 0.1 500 0.1 1 0 Ground ball screw 0.02 High rigidity direct acting 600 Rolled ball screw 0.05 guide 1 5 0.1 500 Slide screw 20

SX3000 Response time ms Type of actuation With light/surge voltage suppressor 15 or less 2 position single 13 or less 2 position double 20 or less 3 position SX5000 Response time ms Type of actuation With light/surge voltage suppressor 26 or less 22 or less 38 or less 2 position single 2 position double 3 position Weights Type of actuation Weight g 67 75 Valve model Single Double Closed center

100 126 141 88 118 148 163 34 44.5 60.5 66.5 10.5 16 19.5 15.5 62 6 x 8 7 x 10 9 x 12 9 x 12 20 24 24 70 92 109 17-4-34 5 Series VNH High Pressure Coolant Valve 3.5 MPa, 7.0 MPa Precautions Be sure to read before handling.

.: 19 (NPT threads: 3/4 inch) B Width across flats 19 OUT Purge air for dehumidification IDG 30, 50, 60, 75, 100 Dimensions (mm) A IDG3, 5, 10, 20 A IN IDG1 Series IDG Series IDG Comes with pre-filter as detailed left + regulator AR. Weight Bracket Weight Bracket Weight Bracket BM65 BM64 BM65 BM59 BM61 BM63 BM64 BM65 1.

Bore size/Stroke (mm) 10 25, 50, 75, 100 Cushion (Option) 15 25, 50, 75, 100, 125, 150, 175, 200 With adjusting bolt (2 pcs.) Nil 25 25, 50, 75, 100, 125, 150, 175, 200 B With shock absorber (2 pcs.) For 15 and 25, strokes up to 300 are available as made-to-order. (-XB11) BS With shock absorber (1 pc.)

T270 WRF-T/T-type clamp arms (Without cover) 2 x M12 x 1.75 depth 24 4 x M8 x 1.25 depth 12 15 60 108 15 80 600.05 +0.015 0 2 x 8H7( ) depth 12 (2 x 4 x M5 x 0.8 through) For limit switch mounting C B A0.5 55 55 1000.3 Switch mounting bracket Note 2) 12 70 12 Fulcrum 13 40 15 10 F 2 x 4 x M10 x 1.5 depth 12 107 Note 3) 70 2 x 2 x 8H7 +0.015 0 ( ) depth 12 60 1 52 (58.7) (70) 95 700.05 85 75

kW 6 sec/min (3 cycle/min) /75 to 110 kW 8 sec/min (4 cycle/min) /220 to 370 kW 4 Component Parts Replacement Parts 6 8 Part no.

Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. q Symbol Description Body size 20 30 40 50 60 25 Nil K Note 1) Without backflow function With backflow function With backflow function w + Nil N F Thread type e Rc NPT G + 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 Port size r + Nil B Note 3) H Note 2) a Without mounting option With bracket

-XN1 / 16 25 40 50 AS568-025V AS568-030V AS568-035V AS568-039V AS568-025 ** AS568-030 ** AS568-035 ** AS568-039 ** B2401-V15V B2401-V24V B2401-P42V AS568-227V B2401-V15 ** B2401-V24** B2401-P42 ** AS568-227 ** 1) FKM:No.1349-80** AS568-025-XN1 2) 4 3) FKM for EPDM Barrel ULTIC ARMOR R R Kalrez Chemraz VMQ R PLASMA R Perfluoro No. 2101-80 70W 4079 SS592 SS630 SSE38 1232-70 3310-75

SealKir 25, 30, 35, 40. 45, 50, 75, 100 25 30,35,4A, 45,50.75, tOD 25, 30, 35.40, 45, 50, 75, 100 .Ho{ to make interrediaie slroke rtrmediale stroke berwen 50-l0o (5s,60,65 ...) are obtained throlgh the use ol spaceB (5. 10, 1s,20mm) (Example) CDQBPSo-55 oMr S[4C would install a 20mrn width spacer in rire cDQ2Bp 50 750M. ll lool brackel is required, order 2 pcs/cylindef.

6 6 6-1 IDU22E IDU37E IDU55E IDU75E 3/min (ANR)( 1) 50Hz/60Hz 3.9/4.3 5.7/6.1 8.4/9.8 11.0/12.5 m MPa 0.7 55 32 10 580 MPa 0.151.0 240 (85%) AC230V10% 50Hz ( 4) V ( 4) AC200/220V10% 50Hz/60Hz ( 4) AC230V (50Hz) 4.3 6.9 10.7 AC200V (2) A (50/60Hz) 4.2/4.8 6.7/7.3 8.2/9.3 AC230V (50Hz) 960 1570 2300 AC200V (2) (50/60Hz) 1100/1450 1570/2050 2000/2850 AC230V (50Hz) 10 20

No.PS-OMU0002CN-D // ZSE20A(F) ISE20A 2 8 10 11 15 15 17 19 [] 22 23 3 24 26 28 28 28 F0 30 F1 OUT1 31 F2 OUT2 34 F3 36 F4 37 F5 FUNC 39 F6 41 F10 42 F11 48 F80 49 F81 50 F82 52 F90 53 F96 55 F97 56 F98 58 F99 60 61 65 65 66 75 75 78 -1No.PS-OMU0002CN-D 1 (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO

The C85/75-XB24 double acting single rod, ISO6432 (C85 only) compatible cylinder with new technology offers at least 4 times longer and environmental resistance compared to standard products. It allows for extended maintenance intervals and has the same dimensions and specifications as the existing C85/75 compact cylinder models.