Example) AR30K-03BE-1NR-B w e V q Body size 20 25 30 40 50 60 Symbol Description V w With backflow function Nil Without backflow function K Note 1) With backflow function + V e Pipe thread type Nil Rc N NPT F G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 V r Port size + a Mounting Nil Without mounting option B Note 3) With bracket H With set nut (for panel mount) + Nil Without pressure
Bit: 7 0 Byte 1 Offset Baud rate (Communication speed) (bit/s) 500 k 250 k 125 k 50 k 20 k 10 k 1 M 800 k Bit: 7 0 Byte 2 Offset Max. bus cable length (m) 25 50 100 250 500 1000 2000 5000 Power supply wiring Power supply connector Bit: 7 0 Byte 3 Offset M12 5-pin plug B-code (reverse) Bit No. 0 2 4 6 0 0 4 6 No. Description Function Output No.
CN2 STAT CN2TB/PC BUS STAT IF ALM SF BF LED 10.LED ALM LED 7 12.LEC 9 - 3 31 DC24V10% 200mA 300mA LEC 5 57words 57word UL , UL1310 Class2 Profibus Profibus DP V1 DP slave 0125 ID 1414 GSD Dsub 9.6k 19.2k 45.45k 93.75k 187.5k 500k 1500k 12000k (bps) (m) 1200 1000 400 200 100 IF RS485(Modbus ) 115.2k 230.4kbps 115.2kbps 28m 3m 5m 5m 5m 5m 5m 10 - 0 40 90%RH ) -10 60
(between lead wire and case) 10 to 60 C Ambient temperature Enclosure IP40 Weight 70 g 1 Trimmer Auto Switch D-7K/D-RK Descriptions Sensor unit 2 1 1 Sensor unit Red light turns ON when sensor detects the magnet field.
P R DC 24V, 12V 24V, 12V Coil rated voltage AC 50/60 Hz (inrush) 110V 110V A DC 3.1W, 0.3W Note3) (Holding) 1.5W Power consumption AC 1.45VA P R Plug-in, L/M type connector (With indicator light and surge voltage suppressor) Electrical entry Latching type specification Note 1) Consult P/A for available combinations. Grommet type entry is N/A with any of these options.
No.PS-OMR0001CN-J // ISA3 1 2 7 8 14 15 2 (ISA3) 15 () 16 (2 ) 16 17 20 26 26 29 34 38 3 41 42 44 44 44 45 45 4 46 46 46 () 58 59 60 5 61 62 62 -1No.PS-OMR0001CN-J 1 (ISO/IEC)(JIS) 1) 2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety
() 1 1 100200 kPa OUT1 OUT2 5 () 3 -20220 kPa 0.005 mm 0.010 mm 0.020 mm (25 ) 0.010 mm 0.015 mm 0.030 mm 0 0 (3) (20) 0200 kPa -20220 kPa / 1 kPa OUT2 6 0.5F.S. 1 digit (25 ) 2F.S. 0 7 600 kPa 1.5 4 5 L/min 12 L/min 22 L/min DC24 V 10(p-p)10() 25 mA 2 (NPN PNP) 10 mA 26.4 V 1 V (10 mA ) 2 LCD 3 7 (/) 6 7 () IP67 8 050 -2070 () 3585RH() AC1000 V 50/60
m³/hr [ANR])@37°F (3°C) PDP; Connections: R threads are standard on sizes 100/125, DIN flange on size 150
m³/hr [ANR])@37°F (3°C) PDP; Connections: R threads are standard on sizes 100/125, DIN flange on size 150
Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size *: 125, 140, 160, 180, 200, Standard stroke *: 10 through 300, Port thread types: Rc, NPT, G, Auto switch capable, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, MW, 40MM CQ2-Z DOUBLE-ROD
3 40 2 20 1 0 0 30 40 50 60 70 80 75 85 95 105 115 125 135 145 155 165 65 Current (mA) Current (mA) Dimensions PVQ13-L PVQ33 PVQ31 27 30 35 22 27 12 10 20.5 =60.6 5 49 24.7 12 2-1/8" 25 * Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
Nil Rc NPT G TN TF L H LOW type (60 mm) HIGH type (90 mm) LOW type HIGH type Guide pin diameter For guide pin diameter, refer to Table 1 below. Body shape Guide pin shape R D Round type Diamond type 90 Mounting surface (viewed from top) 60 Dimension Mounting Mounting hole (tap, pin hole) arrangement Symbol Diamond type guide pin diameter is 17.5 or more.
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): -, Stroke(mm): 125, Max.
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 32, Stroke(mm): 125, Max.
REPEATABILITY OUTPUT FLOW 2.8 SCFM at 20 psi / 7 SCFM at 60 psi 0.2 SCFM at 20 psi AIR CONSUMPTION 5 160 F 1/4" NPT ALUMINUM DIE CAST BODY AMBIENT AND FLUID TEMPERATURE AIR PORT MATERIAL WEIGHT 3.1 lbs. 2.65 lbs. NAMUR FEEDBACK SHAFTS HOW TO ORDER For IP5100 Series.
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Z73, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto