ELECTRICAL CHARACTERISTICS Coil Voltage: 5 to 825 VAC, 50-60 Hz. 1.8 to 265 VDC OPERATING CONDITIONS Media: Air and other non-corrosive gases, water and oil. Filtration: Down to 60 microns or less is recommended.
for input and controling GW 24 VDC GW unit 4 2 3 7 8 Accessory No.
The product Ground terminal +24V Brown +24 VDC +24V Blue 0V Power supply 0V 24 VDC F.G. Be sure to ground.
(Error number 5) Vs : Power supply 24 VDC A : Input signal 4 to 20 mA DC 0 to 20 mA DC Vs : Power supply 24 VDC Vin : Input signal 0 to 5 VDC 0 to 10 VDC 4 points preset input type Brown Blue S1 White Vs Black S2 Vs: Power supply 24 VDC (Negative common) One of the preset pressures P1 through P4 is selected by the ON/OFF combination of S1 and S2.
LEF Auto switch model D-M9NV D-M9N D-M9B D-M9BV D-M9PV D-M9P Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular LEJ LEJ Wiring type 2-wire 3-wire NPN PNP Output type LEL Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) LEM Current consumption 10 mA or less Load voltage 24 VDC (10 to 28 VDC
, PLC 5 to 40mA 40 mA or less D-H7B D-H7A1 24 VDC (10 to 28 VDC) 28 VDC or less 2-wire 3-wire Solid state switch Yes Yes Auto switch mounting method is band mounting only.
Input and control unit power supply: 24 VDC 10% Solenoid valve power supply: 24 VDC + 10%/5% (with power drop warning at approx. 20 V) Power supply voltage range Communication power supply for DeviceNet 11 to 25 VDC How to Order EX500 G DN1 200 mA or less (Single GW unit) Current consumption Communication power supply for DeviceNet 50 mA or less Communication protocol Maximum 64 inputs/
Power for SI Unit/Input Block: 24 VDC 20%, 1.1 A or less Inside of SI Unit: 0.1 A or less Input block: 1 A or less (Depending on number of connecting sensors and specifications) Power for solenoid valve: 24 VDC +10%/-5%, 2 A or less (Depending on number of solenoid valve station and specifications) Connection load: Solenoid valve with protection circuit for 24 VDC and 1.5 W or less surge
Refer to the table for each pressure specification (page 110) Display/set pressure range Display/min. setting unit Power supply Used as switch output device 12 to 24 VDC (10%), and voltage ripple (p-p) 10% at max. voltage Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Electric spec. Power supply voltage 12 to 24 VDC (10%), and ripple (p-p) 10% at max.
Measure the voltages at both sides of the power supply for CompoNetTM. 14 VDC to 26.4 VDC Investigate the cause of the voltage fluctuation, and take countermeasures against it. Confirm the voltage is within the specified range.
range: 19 VDC to power supply voltage Current consumption: 5 mA or less Connect with +24V Voltage range: 19 VDC to power supply voltage Current consumption: 5 mA or less Ionizer stop signal Connect with 0V Voltage range: 5 VDC or less Current consumption: 5 mA or less Connect with 0V Voltage range: 5 VDC or less Current consumption: 5 mA or less Input signal Cleaning signal Maximum load
DXT170-176-2-01 DXT170-176-2-02 100V 200V 100 VAC 200 VAC DXT170-176-2-03 110V 110 VAC DXT170-176-2-04 220V 220 VAC DXT170-176-2-07 DXT170-176-3-51 DXT170-176-3-06 DXT170-176-3-05 DXT170-176-3-53 240V 6VD 12VD 24VD 48VD 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC Circuit with Indicator Light AC circuit DC circuit NL: Neon bulb R: Resister D: Protective diode LED: Light emitting diode R: Resistor 4
VXK21 VXK22 VXK23 Model 2 mm 3 mm 4.5 mm 6 mm 8 mm Orifice size Orifice size M Solenoid Coil Coil: Class B, Class H M Rated Voltage 100 VAC, 200 VAC, 110 VAC, 220 VAC, 240 VAC, 230 VAC, 48 VAC, 24 VDC, 12 VDC 1/8 1/4 1/4 3/8 1/4 3/8 Port size Normally Open (N.O.)
Brown DC (+) Brown DC (+) Load Main circuit Black OUT1 Black OUT1 Output (OUT2) display (Red) Load 12 VDC 12 VDC Load + + White OUT2 White OUT2 24 VDC to to button (SET) 24 VDC Load FUNC Blue DC () FUNC Blue DC () LED display Max. 80 mA Residual voltage: 2 V or less Max. 28 V, 80 mA Residual voltage: 2 V or less button (UP) button (DOWN) The FUNC terminal is connected when using the copy
CKQ CLKQ Relay, PLC Note 1) D-P4DWZ 5 m 2-wire (14) 2-color display CK1 D-P79WSE 24 VDC 0.3 m Pre-wired connector Reed auto switch DC/AC magnetic field CLK2 Series C(L)KQP D-P74L 3 m 24 VDC 100 VAC 1-color display 2-wire Grommet D-P74Z 5 m Note 1) PLC: Programmable Logic Controller Note 2) There are other applicable auto switches other than the listed above.
6 12 VDC V 6 VDC S 5 VDC R 3 VDC F G Supply valve/Release valve combination Pilot valve J K Supply valve Nil DC: 1 W (With indicator light: 1.5 W) AC Supply valve and release valve A Supply valve (N.O.)
, 600 or less with 24 VDC output Power supply voltage 12 to 24 VDC 10% Current consumption 20 mA or less (without load) Enclosure IP65 Environmental resistance Operating temperature range Operating: 0 to 50C, Stored: 25 to 85C in stock (with no condensation and freezing) Voltage resistance 1000 VAC for 1 min. between external terminals and case Insulation resistance 50 M or more (500 VDC
10% 12 to 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% 24 VDC 10% Temperature characteristics (25C reference) 3% F .S. (15 to 35C) 5% F .S. (0 to 50C) 2% F .S.
, variable from 0 to 60 s/0.01 s increments Hysteresis Variable from 04 Protection Over current protection Input type Voltage input: 1 to 5 VDC (Input impedance: 1 M) Number of inputs 4 inputs Connection method e-CON Protection Over voltage protection (up to a voltage of 26.4 VDC) Auto-shift input5 Voltage free input (Reed or Solid state), input for 5 ms or longer, Independently controllable
/ 4 W 24 VDC/ 4 W 12 VDC/ 4 W 24 VDC/ 4 W 12 VDC/ 6 W 24 VDC/ 6 W Electric specifications 8.4 VDC (Rated 35%)/ 0.8 W Allowable voltage fluctuation*5 10% of rated voltage (0 to +10%) Type of coil insulation Class B 5 VDC (Rated 42%)/ 0.7 W 10 VDC (Rated 42%)/ 0.7 W 5 VDC (Rated 42%)/ 0.7 W 10 VDC (Rated 42%)/ 0.7 W 4.2 VDC (Rated 35%)/ 0.8 W Holding*2 Holding voltage/ Power consumption *1