COM Max. 30 VDC, 50 mA CEU2 OUT4 Load COM U Valve driving output COM Valve BR PNP transistor output Controller: CEU2P U Valve driving output OUT1 Load Valve B COM Max. 30 VDC, 50 mA CEU2P OUT4 Load U COM Valve driving output Valve B However, on the valve output side, the COM of the input circuit and the COM of the output circuit are electrically insulated from each other. 24 VDC 24 VDC E
insulated from each other. 24 VDC ML2B 24 VDC C J G5-S Electrical Wiring CV
insulated from each other. 24 VDC ML2B 24 VDC C J G5-S Electrical Wiring CV
Indicator light Output 1 and 2: Orange Power supply Used as switch output device 12 to 24 VDC, including ripple (p-p) 10% voltage Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Current consumption 50 mA max.
Power for SI Unit/Input Block: 24 VDC 20%, 1.1 A or less Inside of SI Unit: 0.1 A or less Input block: 1 A or less (Depending on number of connecting sensors and specifications) Power for solenoid valve: 24 VDC +10%/-5%, 2 A or less (Depending on number of solenoid valve station and specifications) Connection load: Solenoid valve with protection circuit for 24 VDC and 1.5 W or less surge
24 VDC +10%/-10% Under-voltage detection approx. 18 VDC PWR(V) Operating voltage 24 VDC +10%/-5% Galvanic isolation Yes (between PWR and PWR(V)) Fieldbus Bus protocol PROFINET I/O Version PROFINET Specification Version 2.3 Conformance Class C Yes (Only for IRT switch function) FSU (Fast Start Up) Yes MRP (Media Redundancy Protocol) Yes MRPD (Media Redundancy for Planned Duplication) Yes
Failure of the power supply for the input and control Supply 24 VDC 10% to the power supply for the input and control.
VEX1 Nil H C37 Stainless steel FKM Voltage SRH 5 6 24 VDC Thread type (with sub-plate) 12 VDC SRP Nil F N T Rc Electrical entry: Grommet G SRF NPT NPTF Orifice size ARX20 Port size Orifice dia. Max. operating pressure Symbol 16 23 40 VCHR 1.6 mm 0.7 MPa Without sub-plate (with mounting screw M3 x 8L, 2 pcs.)
Operating voltage range 21.6 to 26.4 VDC Rated input current 5 mA TYP Input impedance 4.7 kW Input signal Rated load voltage 48 VAC or less/30 VDC or less Max. load current 500 mA AC/DC (Resistance load) Min. load current 5 VDC 10 mA Output voltage 24 VDC 10% 200 mA MAX (No inductive load) Contact output signal Product side Customer system side 1 Contact input signal COM 1 k 2 Contact input
supplies for logic/input and output) Operating voltage range 24 VDC +10%/-10% For logic/input Under-voltage detection approx. 16.8 VDC For output Operating voltage range 24 VDC +10%/-5% Isolation Yes (Between power supplies for logic/input and output) Fieldbus Bus protocol IO-Link Version 1.1 IO-Link type Device IO-Link Port Class Class B Transmission rate COM2 (38.4 kbps) Firmware update
Maximum load current 500 mA AC/DC (Resistance load) Contact output signal 1, 2, 3 Minimum load current 5 VDC 10 mA 24 VDC Output voltage 24 VDC 10% 500 mA MAX1 (No inductive load) 1 When using the power supply of this product, make sure that the total load current is 500 mA or less. Contact Input/Output Pin Nos. Pin no.
Name Lead wire colour Function 1 L+ Brown 18 to 30 VDC 2 N.C.
node number setting 1 to 64 Station type Remote I/O node Transmission speed 156 kbps 625 kbps 2.5 Mbps 5 Mbps 10 Mbps Min. cable length between nodes 20 cm or more Max. total cable length 1200 m 900 m 400 m 160 m 100 m Rated voltage 24 VDC Power supply for SI unit: 24 VDC 10% Power supply for the solenoid valves: 24 VDC +10/-5% Power supply voltage range (Voltage drop warning is generated
Check that the power supply voltage is within the range of 12 to 24 VDC 10%. Supply the correct voltage of 12 to 24 VDC 10%. Incorrect power supply Power saving mode Check if the power saving mode is selected. Reset the function settings. Indicator turns off. 9 Check the power supply wiring.
Incorrect operation of the internal data of the Pressure switch (Er0, Er4, Er6,Er7) System error (Er0, Er4, Er6 or Er7) is displayed. (2) Check that the power supply voltage is within the range 12 to 24 VDC 10%. The display shows "HHH". 7 (2) Supply a correct voltage of 12 to 24 VDC 10%.
5 6 4 position dual 3 port valve (B) 2 position double (metal) 24 VDC Note) (A) 4 (B) 2 (A) 4 (B) 2 B Note) S kit is only available for 24 VDC.
12 VDC 230 VAC All types equipped with surge voltage suppressor.
[Option] How to Order Light/Surge voltage suppressor Rated voltage Nil S Z R U Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor With surge voltage suppressor (Non-polar type) With light/surge voltage suppressor (Non-polar type) DC CE-compliant 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC For AC voltage valves there is no S option.
DC 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC Bracket Nil: Without bracket F: With bracket AC (50/60 Hz) 3 port 1 2 3 4 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, DC voltage is only available. Type of actuation Bracket 1 2 Normally closed Normally open (For manifold type 20, 20R) Bracket is mounted.
D-S79# D-S99# D-S99V# D-S7P# D-S9P# D-S9PV# D-T79#(C) D-T99# D-T99V# Lead wire orientation In line Perpendicular In line Perpendicular In line Perpendicular Wiring 3-wire 2-wire Output NPN PNP Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5/12/24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current