Function selection mode In measurement mode, press the button between 3 and 5 seconds, to display [F 0]. Select to display the function to be changed [F ]. Press and hold the button for 2 Measurement mode Power is supplied. Press the button between 3 and 5 seconds.
Caution: [F 4] Auto-preset function OFF [F81] Security code OFF Press the button once.
NY-325 NY-800 NY-1000 CB 1.265 1.515 3.032 CD 0.75 1 1 3/8 CE 2 3/8 3 1/8 4 1/8 CH 1 3/8 1 1/2 2 CW 5/8 3/4 1 F 1 1/4 1 1/2 2 L 1 1/4 1 1/2 2 1/8 A 1 1/8 1 5/8 2 KK 3/4-16 1-14 1 1/4-12 ER 3/4 1 1 3/8 Weight (lbs) 1.50 3.78 9.32 Note: Jam nut, pivot, and cotter pins are included. 12 Alignment Coupler F Shank dia.
A B C D E F G H J 1.6 M5 2.3 3.2 For other special options, refer to page 462.
Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.
ZH ZU Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZL Vacuum Switch/Suction Filter Unit: ZR1-F ZY Specifications ZQ Unit no. ZR1-F Vacuum to 0.5 MPa 5 to 50C 30 m PVF Refer to page 13-3-13 regarding vacuum switch.
1/8 81 M24 x 1.5 13 28 19 15 143 32 Up to 800 21 M14 x 1.5 24 22 38 16 19 12 8 53 8 9 40 31 f8 7.5 1/8 87 M30 x 1.5 13 36 19 15 159 40 Up to 800 21 M33 x 2 M16 x 1.5 24 24 41 18 21 14 11 54 10 11 48 34 f8 7.5 1/4 108 19 44 24 21 183 Axial foot type: CHML Width across flats B2 H N GA F N GB F Rc P Rc P 2 x NN Width across flats B1 Effective thread H2 H1 D I 4 x LD LH MM A K NC Width across
28 60 86 (mm) J 72 130 170 H 348 466 546 G 288 406 486 F 188 246 286 E 80 138 178 D 164 222 262 B C 116 174 214 112211221122MHL2-40D MHL2-40D1 MHL2-40D2 268 386 466 931
Fittings & Tubing Air Cylinders Rotary Actuators 2 x P (Rc, NPT, G) H2 Width across flats B2 2 x NN G Relief port M5 x 0.8 G H1 Width across flats B1 Standard port I Relief port 2 x Eh8 D MM AL A F K NA N N H S + Stroke F ZZ + Stroke (mm) ZZ S P N I E D A 12.5 11 10 10 13 F Bore size Stroke range AL K MM NA NN G H2 41 32 32 26 B2 H H1 22 17 17 13 B1 0 6 6 5 8 8 8 50 45 45 41 200 to 1000 150
MVGQ CC RB J D-X 20Data 10-6-11 11 Series RHC Dimensions: Basic Style 20 to 40 Rc P Rc P GA H2 NN NN GB I H1 MM D NB ND NE C Effective thread E E NF 10 N JD N JC 10 A K F NA S + Stroke F H WH B ZZ + Stroke Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B C D E
Guide shaft mounting surface n = 1 + 2 + 3 + 4 = 0.20 + 0.24 + 0.13 + 0.16 = 0.73 n = 0.73 1 Therefore it can be used. 8-17-5 5 Series CYP Model Selection 3 Caution on Design (2) Table Deflection Note) Table deflection due to pitch moment load Table deflection due to yaw moment load Table deflection due to roll moment load Guide central axis F A F F L L A L Guide central axis A M1 = F x
Rubber back of the belt is softened and sticky f . Cracks on the back of the belt are visible The traveling parallelism is the reference plane for the body mounting reference plane. If the traveling parallelism for a table is required, set the reference plane against parallel pins, etc.
.) : Setting of the normal/reverse output switching and hysteresis/window comparator mode switching are performed with the function selection mode [F 1] OUT1 setting and [F 2] OUT2 setting. Peak/bottom value indication The max. (min.) pressure when the power is supplied is detected and updated.
(The default setting does not include arbitrary display.) 6 Display colour Output ON: Green/ Output OFF: Red (Linked to OUT1) 9 8 8 [F 0] Setting of the switching function of the pressure range, display unit and switch output specifications is completed. 4.5 4.5 [F 2] Setting of OUT2 Same setting as [F 1] OUT1. 28 Press the button between 1 and 3 sec.
Standard condition [F 4] [F 5] [eES] Response time [1.00] 1 second Specifications / Outline with Dimensions [F 6] [dSP] Display mode [ inS] Instantaneous flow [F 7] [ inP] External input [ r_r ] Accumulated flow external reset Refer to the product catalogue or SMC website (URL http://www.smcworld.com) for more information about the product specifications and outline dimensions. [1E2] 100-
Field name Example RTU mode ASCII mode (HEX) character data binary data Header : None Device address 0x01 0,1 0x01 Function 0x04 0,4 0x04 Quantity of bytes to read 0x02 0,2 0x02 Information of 0009h(Data display 1) 0x00FA 0,0,F,A 0x00,0xFA Checksum ASCII:LRC RTU:CRC F,F 0x39,0x73 Trailer CR/LF None Total quantity of byte 15 7 * Response message at an ambient temperature of 25.0C 3.13 Register
Move M Speed Position Pushing F TriggLV In pos Change of positioning stop position Position: 50mm 30mm mm/s mm % % mm 0 Absolute 250 50.00 0 0 0.50 Input 30 Step data No. Move M Speed Position Pushing F TriggLV In pos mm/s mm % % mm 0 Absolute 250 30.00 0 0 0.50 6.
e. f. -46- 7.5. 1. 2. (1mm ) 3. 4. N Nm LEY16 LE-D-2-1 10 0.36 LEY25 LE-D-2-2 19 0.63 LEY32 LE-D-2-3 30 1.5 5. LEY32 Nm LEY16 0.63 LEY25 1.5 LEY32 5.2 6. -47- 8.