Besides, the overall length is longer than the cylinder with air cushion as follows, because the bumpers are attached to the both sides of the piston: 32, 40: +6 mm, 50, 63: +8 mm, 80, 100: +10 mm. 32 40 50 63 80 100 90 90 102 102 124 124 164 200 200 141 145 164 Stroke range Bore size (mm) Effective thread length Width across A D Ee11 F G H MB J K MM N P S V W ZZ C B flats 19.5 27 32 32
Part no. 25 32 40 50, 63 0.040 0.076 0.040 0.076 0.040 0.076 0.050 0.093 CD-MU02 CD-MU03 CD-MU04 CD-MU05 25 32 40 50, 63 8 10 10 14 M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 17 19 22 27 18.2 22.2 26.2 32.2 6 7 8 11 19.6 21.9 25.4 31.2 16.5 18 21 26 23 27 31 38 7.6 9.6 9.6 13.4 NT-03 NT-MU03 NT-04 NT-05 A nut is attached with rod end male thread as standard. (Double rod type: 2 pcs.)
-X14 424 Ionizer IZS40/41/42 Series Specifications IZS41(NPN) IZS41-P (PNP) IZS42(NPN) IZS42-P (PNP) IZS40 Ionizer model Dual AC 6,000 V AC, DC Corona discharge type Ion generation method Method of applying voltage Applied voltage Offset voltage Note) AC, Sensing AC, DC 7,000 V IZS IZS Within 30 V Air (Clean dry air) 0.5 MPa or less 0.7 MPa 6, 8, 10 Fluid Operating pressure Proof pressure
Besides, the overall length is longer than the cylinder with air cushion as follows, because the bumpers are attached to the both sides of the piston: 32, 40: +6 mm, 50, 63: +8 mm, 80, 100: +10 mm. 32 40 50 63 80 100 90 90 102 102 124 124 164 200 200 141 145 164 Stroke range Bore size (mm) Effective thread length Width across A D Ee11 F G H MB J K MM N P S V W ZZ C B flats 19.5 27 32 32
Part no. 25 32 40 50, 63 0.040 0.076 0.040 0.076 0.040 0.076 0.050 0.093 CD-MU02 CD-MU03 CD-MU04 CD-MU05 25 32 40 50, 63 8 10 10 14 18.2 22.2 26.2 32.2 M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 17 19 22 27 6 7 8 11 19.6 21.9 25.4 31.2 23 27 31 38 16.5 18 21 26 7.6 9.6 9.6 13.4 NT-03 NT-MU03 NT-04 NT-05 A nut is attached with rod end male thread as standard. (Double rod type: 2 pcs.)
Bore d2 CK S5 K1 K2 l3 G1 l1 G2 EM G3 CA H6 R1 32 11 10 6.6 38 51 10 21 7 18 26 31 32 8 10 40 11 12 6.6 41 54 10 24 9 22 28 35 36 10 11 50 15 12 9 50 65 12 33 11 30 32 45 45 12 12 63 15 16 9 52 67 14 37 11 35 40 50 50 12 15 80 18 16 11 66 86 18 47 12.5 40 50 60 63 14 15 100 18 20 11 76 96 20 55 13.5 50 60 70 71 15 19 Mounting type CR Rear clevis with ball joint A B C D EN ER F G E L M N P
Port size Rc1/4, NPT1/4, G1/4 (ISO1179) Letter height 10mm M12 connector Lead wire with M12 connector (5m) 2 types: Straight and right angle Functions Key lock Anti-chattering Unit conversion (fixed with SI units inside Japan) Display calibration Zero clear Straight Right angle ISE70 ISE75 ISE75H MPa MPa MPa OUT1 OUT1 OUT1 Model U P DOWN U P DOWN U P DOWN SET SET SET Gray Orange Solid
From the View menu bar "parameter (A)" please click on the "parameter setting (P)". "Parameter Settings" screen will be displayed. Please click on Read". 6.3.3 Parameter setting method Please set the parameters for each actuator. Refer to "LECSS Operation Manual,chapter 5 for details of each parameter.
SOL.ASOL.B 1 AC 2 SOL.ASOL.B 1 DC24V 2 () () 1.1Nm ) SOL.ASOL.B 1 AC 2 SOL.ASOL.B 1 DC24V 2 9 VFR3000-OMJ0001-A VFR3000 VFR3000 VFR3000 VFR3000 Series Series Series Series 3 3 3 3 DIN DIN DIN DIN / / / / 01T 01T 01T 01T DIN (A B AB) COM 1.25-3.5M1.25Y-3L1.25-3M VFR3000 AB+ B+COM -COM 90 O 1) 0.9MPa 2) 3) MAX.50 4) 2 5) P 3 AB ARBF3000 P AB ARBF3050 A B P 1.0MPa 1)
Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.
Valve; Stop Valve: None), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display
Valve; Stop Valve: None), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display
Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: P (w/o Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: L2 [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: None], Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: L2 [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: None], Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Valve; w/Stop Valve), Return Port Size: 03 (3/8), Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow
Valve; w/Stop Valve), Return Port Size: 03 (3/8), Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow
Valve; w/Stop Valve), Return Port Size: 03 (3/8), Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: