SMC Corporation of America
Elite Part Number Search
Search Results "VNH111A-10A-5DZ-B-Q"

Compatible Fluid: Air / Water / Vacuum / Oil / Gas, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Open, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 3/8, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Operating Pressure Difference

Compatible Fluid: Air / Water / Vacuum / Oil / Gas, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 3/8, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Operating Pressure Difference

Compatible Fluid: Air / Water / Vacuum / Oil / Gas, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 3/8, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Operating Pressure Difference

Size: 2 [ø15(ø11)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: NBR seal, Thread: Rc(PT), Port Size: 3/8, Voltage: 24VDC, Lead Wire: DIN Terminal w/Light & Surge Voltage Suppressor, Manual Override: -, Bracket: -, CE Compliant: -

Size: 1 (ø10), Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: A (NBR), Thread: Rc, Port Size: 10A (3/8), Voltage: 5 (24VDC), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor)

Size: 1 [ø7], Valve Type: 2 [NO (Operating Pressure 1MPa)], Sealant: B (FKM Seal), Body Material: Standard, Pilot System Option: Standard, Thread: Rc(PT), Port Size: 10A (3/8), Voltage: 5 (24VDC), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor)

Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: A (NBR seal), Thread: Rc(PT), Port Size: 10A (3/8), Voltage: 5 (24VDC), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor)

Size: 2 [ø15(ø11)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: B (FKM Seal), Body Material: Standard, Pilot System Option: Standard, Thread: Rc(PT), Port Size: 10A (3/8), Voltage: 5 (24VDC), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor)

Size: 1 (Port Size 3/8), Number of Ports: 3 (2 Port), Valve Type: 3 [NC (Operating Pressure 7.0MPa)], Gasket: A (NBR Seal), Thread: Rc(PT), Port Size: 10A (3/8), Voltage: 5 (24VDC), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor)

Size: 2 [ø15(ø11)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: B (FPM seal), Thread: Rc(PT), Port Size: 10A (3/8), Voltage: 5 (24VDC), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor)

Size: 2 [ø15(ø11)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: A (NBR seal), Thread: Rc(PT), Port Size: 10A (3/8), Voltage: 5 (24VDC), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor)

MTS Air pressure supplied from A operates on both surfaces q and w. (Extension) MY q w A B Piping is concentrated in the head cover. CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Air pressure supplied from B operates on surfaces e.

Q = qm x C x (T2 T1) x qv x C x iT 60 1 x 70 x 4.186 x 103 x 4.0 60 = = qm x C x (T2 T1) 860 Q = = 19535 [J/s] 19535 [W] = 19.5 [kW] x qv x 60 x C x iT 860 = Cooling capacity = Considering a safety factor of 20%, 19.5 [kW] x 1.2 = 23.4 [kW] 1 x 70 x 60 x 1.0 x 103 x 4.0 860 = Thermo-chiller T1: Outlet temperature Q: Heat generation amount 1680 [cal/h] 860 Users equipment = T = T2 T1

w q w q Unit psig/bar MPa Code No code MPA Sample Order Number Port AZ1001S e q FV4 FV4 FV4 w FV4 FV4 FV4 r 2PW 3PW 4PW 2PW 3PW 4PW 2) Pressure gauge unit MPa or psig/bar selectable.

SI unit for VQC/S0700 series valve ( EX500-Q ) Current consumption Supply current for block Supply voltage for block Connected block station Connected block Solenoid valve ( single, double ) General purpose output block ( EX500-Q 02 only ) Supply current for block 0.65A Max.

B + Stroke A + Stroke 20, 25 Rod end male thread Rod end nut Rod End Male Thread Bore size (mm) 12 16 20 25 H1 M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.25 X 10.5 12 14 17.5 L1 14 15.5 18.5 22.5 C1 9 10 12 15 Basic Style Without auto switch With auto switch Bore size (mm) Stroke range (mm) A 25.5 25.5 29 32.5 C E F H I K L M N OA OB Q RA RB T B 22 22 24.5 27.5 A 30.5 30.5 39 42.5 B 27 27 34.5

q Check the actuator label for model number. This matches the controller/driver. w Check Parallel I/O configuration matches (NPN or PNP). q w * Refer to the operation manual for using the products.

with level gauge With bowl guard Metal bowl with level gauge Metal bowl Semi-standard specifications B B B 10-/21-AW20-B 10-/21-AW30-B 10-/21-AW40-B 10-/21-AW40-06-B 10-/21-AW60-B 142.1 174.1 176.1 261.1 93.9 122.1 154.1 156.1 241.1 91.4 Dimensions B B B B Standard specifications Model Optional specifications Round type pressure gauge Bracket mounting size Panel mount Q R S T U V W Y Z

A B Weight [g] ZP3P-T50PTSFJ10-B01 40.5 107 101.3 ZP3P-T50PTSFJ20-B01 50.5 112.5 102.3 Part no. A B Weight [g] ZP3P-T50PTSFK10-B01 40.5 107 100.7 ZP3P-T50PTSFK20-B01 50.5 112.5 101.8 8 ZP3P Series Construction Pad with Adapter Male thread Female thread e w w q q Component Parts No.