When two or more symbols are specified, indicate them alphabetically. 2-3-7 8 Series SQ1000 Manifold Option Blanking plate SSQ1000-10A-3 Individual SUP/EXH spacer SSQ1000-PR1-3Name plate (-N) SSQ1000-N3-n External pilot specifications (-R) P. 2-3-44 P. 2-3-45 P. 2-3-47 P. 2-3-48 C6 L6 External pilot port SUP/EXH block SSQ1000-PR-3-C8 (-S) SUP block plate SSQ1000-B-P Blanking plug KQ2P-23/04
Local Area: (800) 258-9200-www.stevenengineering.com 50% 30% 10% 70% 50% 70% 10% 0 0 800 400 MB 80 MB 63 300 600 Stroke (mm) AS5000-02 AS420-02 AS3201F -03-10 200 400 200 100 0 0 SV400 AN300 -KM12 T1209 SV300 ANA1 -C12 T1075 800 400 MB 100 MB 80 600 300 Stroke (mm) AS5000-02 AS420-02 AS4000-03 400 200 200 100 0 0 400 800 CS1 125 MB 100 600 300 Stroke (mm) AS5000-02 AS420-02 200 400 AS4000-04
DXT170-176-2-01 DXT170-176-2-02 100 VAC 200 VAC 100V 200V DXT170-176-2-03 220V 110V 110 VAC DXT170-176-2-04 220 VAC DXT170-176-2-07 DXT170-176-3-51 DXT170-176-3-06 DXT170-176-3-05 DXT170-176-3-53 240 VAC 240V 6VD 12VD 24VD 48VD 6 VDC 12 VDC 24 VDC 48 VDC Circuit with Indicator Light AC Circuit diagram DC Circuit diagram D: Protective diode LED: Emitting diode R: Resister NL: Neon bulb R:
Port size Body size Thread size Thread type Symbol N F Rc NPT G 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 An interface part is required if a spacer or spacer with bracket shown in the table below is attached to a modular FRL.
Body Size: 40, Model Type: B (Air Filter + Regulator), Thread: Rc, Port Size: 04 (1/2), Float Type Auto Drain: w/o Auto Drain, Pressure Gauge/Digital Pressure Switch: w/o Pressure Gauge, Attachment: V (Mounting Position: AF + AFM + AR + V), Set Pressure: 1 (0.02 to 0.2 MPa Setting), Bowl Type + Lubricator: Standard (Polycarbonate Bowl + Lubricator), Bowl Guard: None, Air Filter Drain Port
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Size: 3 (30), Valve Type: 1 (Normally Closed), Body Material: A (Aluminum), Seal Material: N (NBR), Port Size: 04 (Thread; 1/2), Thread Type: N (NPT), Rated Voltage: 5 (24 VDC), Electrical Entry: G (Grommet)
Body Class: 4 (Class 4, Orifice ø12), Valve Type: 0 (Normally Closed), Port Size: 04 (1/2), Thread: R, Rc, Material: A (Body: SUS, Endplate: PPS, Diaphragm: PTFE), Option: None, Specification: V (Vacuum)
.: 04 (ø4), Thread: R, Port Size: 01 (1/8)
.: 04 (ø4), Thread: R, Port Size: 01 (1/8), Seal Method: S (with Sealant)
.: 04 (ø4), Thread: R, Port Size: M5 (M5 x 0.8)
.: 04 (ø4), Thread: R, Port Size: 01 (1/8)
.: 04 (ø4), Thread: R, Port Size: 01 (1/8), Seal Method: S (with Sealant)
.: 04 (ø4), Thread: R, Port Size: M5 (M5 x 0.8)
.: 04 (ø4), Thread: R, Port Size: M3 (M3 x 0.5)
.: 04 (ø4), Thread: R, Port Size: M3 (M3 x 0.5)
Size: 40, Thread Type: Rc, Port Size: 04 (1/2), Mounting: w/o Mounting Option, Float Type Auto Drain: D [N.O. (Normally Open)], Bowl: Sizes 20, 30, 40: Polycarbonate Bowl; Sizes 50, 60: Stainless Steel, Drain Port: w/Drain Cock, Indicator: w/o Indicator, Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units: MPa
Size: 40, Thread Type: N (NPT), Port Size: 04 (1/2), Mounting: w/o Mounting Option, Float Type Auto Drain: C [N.C.
Size: 40, Thread Type: N (NPT), Port Size: 04 (1/2), Mounting: w/o Mounting Option, Float Type Auto Drain: D [N.O.