Series: 344 (VP300), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: T (w/Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: T (NPTF), Actuation: A (N.C., Normally Closed
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: T (w/o Operation
Series: 544 (VP500), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 6 (12VDC), Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: T (NPTF), Actuation Type: A (N.C., Normally Closed)
IP5x or IP65 (option “P”); Maximum work load: 200 kg (horizontal); 115 kg (vertical)(T motor spec, top/parallel mount); Maximum pushing force: 1910 N; Maximum stroke: 800mm; Positioning repeatability: ±0.02mm, ±0.01mm (high precision option); Encoder resolution: 17-bit (S motor), 22-bit (T motor), 20-bit (V motor)
The WRF100 with its high clamping force makes it suitable for a broad range of applications. Standardized T-type and S-type arms allows the selection to meet certain specifications or applications. Also, has an optional spatter protective cover with easy assembly even after the cylinder is installed.
The WRF100 with its high clamping force makes it suitable for a broad range of applications. Standardized T-type and S-type arms allows the selection to meet certain specifications or applications.
IP5x or IP65 (option “P”); Maximum work load: 200 kg (horizontal); 115 kg (vertical)(T motor spec, top/parallel mount); Maximum pushing force: 1910 N; Maximum stroke: 800mm; Positioning repeatability: ±0.02mm, ±0.01mm (high precision option); Encoder resolution: 17-bit (S motor), 22-bit (T motor), 20-bit (V motor)
), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: CM1 (JXCM1 CC-Link, Direct Input Type), I/O Cable Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)
), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: CM1 (JXCM1 CC-Link, Direct Input Type), I/O Cable Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)
Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: CM1 (JXCM1 CC-Link, Direct Input Type), I/O Cable Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)
Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: CM1 (JXCM1 CC-Link, Direct Input Type), I/O Cable Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)
Flexible Cable), Actuator Cable Length: B (15m), Controller Type - LEC, JXC: CM1 (JXCM1 CC-Link, Direct Input Type), I/O Cable Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)
Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: CM1 (JXCM1 CC-Link, Direct Input Type), I/O Cable Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)
Cable Length: 5 (5m), Controller Type - LEC, JXC: CM1 (JXCM1 CC-Link, Direct Input Type), I/O Cable Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)
Cable Length: 5 (5m), Controller Type - LEC, JXC: CM1 (JXCM1 CC-Link, Direct Input Type), I/O Cable Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)
(10m), Controller Type - LEC, JXC: CM1 (JXCM1 CC-Link, Direct Input Type), I/O Cable Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)
(10m), Controller Type - LEC, JXC: CM1 (JXCM1 CC-Link, Direct Input Type), I/O Cable Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)