million cycles VQC2100: 20 ms 2 ms; 200 million cycles VQC4100: 17 ms 3 ms; 100 million cycles '-t t iS nge mounting screw Avai abe configurations lN.C.
SUP = 0.2 MPa 0.2 0.2 0.2 0.1 0.1 0.1 0 0 0 50 100 150 200 0 Discharge (mL/min) 0 Discharge (mL/min) 200 400 600 800 1000 0 Discharge (mL/min) 200 400 600 800 1000 Air Consumption: Built-in Solenoid Valve/Air Operated Calculation of Air Consumption Air Consumption 45 Find the air consumption for operation with a 5 Hz switching cycle and pilot air pressure of 0.35 MPa from the air consumption
Nil S n Front nose mount Rear pivot mount Double end mount B C E Nil Without auto switch Auto switch Bore size 3/4" 1 1/16" 1 1/2" 2" 075 106 150 200 For the applicable auto switch model, refer to Best Pneumatics Stroke Hundredths of an inch (i.e. 06 = 0.06") Standard stroke Inches Specifications Specifications 075 (3/4") 200 (2") 106 (1 1/16") 150 (1 1/2") Bore size (in) Fluid Air Maximum
Flow rate Power consumption Operating frequency 100 Hz 500 Hz 1000 Hz 80 W 1200 Hz Low flow type 50 L/min 40 W 1000 Hz 10 W 550 Hz 4 W 350 Hz 80 W 650 Hz Medium flow type 100 L/min 40 W 550 Hz 10 W 300 Hz 4 W 200 Hz 80 W 600 Hz High flow type 150 L/min 40 W 500 Hz 10 W 250 Hz 4 W 150 Hz VCH VDW SX10 SX10 Select a model according to applications and purposes.
(120) 3 position 0.35 0.48 [0.57] [0.41] [1.3] center 3.3 0.78 0.43 Pressure 0.45 0.56 2.1 [0.85] [0.25] [0.54] center 170 (90) Single 2.3 0.61 0.35 0.74 2.9 0.41 2 position 190 (110) Double Closed 1.9 0.50 0.44 0.60 2.2 0.46 center 1/4 Note 1) M5 x 0.8 SYJA740-02 Exhaust 0.27 0.87 3.7 3 position 1.3 200 (120) 0.35 0.45 center [0.56] [1.4] [0.43] 3.6 Pressure 0.84 0.23 0.47 0.58 2.1 [0.83
Grommet Class B coil: AWG20 Outside insulator diameter of 1.8 mm 2 port q w Lead wire color Rated voltage w Red Blue Red Gray q Black Blue Red Gray DC 100 VAC 200 VAC Other AC Maintenance Warning There is no polarity. 1. Removing the product The valve will reach a high temperature when used with high temperature fluids.
72 74 41 590 AMV 3/4 200 72 74 41 710 1 200 72 74 41 605 AMP 1 200 72 74 41 725 1 230 72 74 41 665 1 230 72 74 41 810 11/4 240 72 74 54 765 11/4 240 72 74 54 910 11/2 240 72 74 54 790 11/2 240 72 74 54 935 609 5.0 MPa 5.0 MPa Applications included air-blowing, charging fluid into a vessel, or discharging (Blow-molding equipment, etc.)
Flow Rate Characteristics Relief Characteristics IR1220-01-A Supply pressure: 0.7 MPa IR1220-01-A Back pressure: 0.7 MPa 0.7 0.7 0.6 0.6 Set pressure [MPa] Set pressure [MPa] 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 200 400 600 800 0 0 50 100 150 200 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Pressure Characteristics Supply pressure: 0.3 to 1.0 MPa Set pressure: 0.2 MPa Flow rate:
M5 x 0.8 12-CY3B10 10 500 50, 100, 150, 200, 250, 300 15 1000 12-CY3B15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rc1/8 NPT1/8 G1/8 25 12-CY3B25 (Both sides) Non-lube 32 12-CY3B32 1300 Rc1/4 NPT1/4 G1/4 12-CY3B40 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-CY3B50 50 12-CY3B63 63
to 230 VAC (50/60 Hz) Single phase 200 to 230 VAC (50/60 Hz)Three phase 170 to 253 VACSingle phase 170 to 253 VAC1.5Single phase 200 to 230 VAC (50/60 Hz)Single phase 170 to 253 VAC0.210 inputs6 outputs1 M (when differential receiver), 200 k (when open collector)0 to ?
958 219 78 100 11.0 463 916 485 170 IDF90 Anchor bolt location Hole diameter:13 Unit: mm IDF80 IDF90 IDF60 745 (957) (Air dryer outside) (Air dryer outside) 704 916 (Air dryer outside) 330 355 (Air dryer outside) (485) 463 IDF70 890 (Air dryer outside) 849 (Air dryer outside) 365 390 IDF60/70/80/90 Series 7.3 Dimensions 7-3 IDX-OM-V022 Chapter 7 Documents 7.4 Electric circuit IDF60/70 200
Tubing for AD27-D: I.D. 2.5 (3/32") or larger, Length 5 m (200 inch) or shorter Tubing for AD37, 47(N)-D: I.D. 4 (3/16") or larger, Length 5 m (200 inch) or shorter Tubing for AD38, 48(N)-D: I.D. 6.5 (1/4") or larger, Length 5 m (200 inch) or shorter 8) Pipework for auto drain discharge which rises higher than the auto drain outlet should be avoided.
Tubing for AD27-D: I.D. 2.5 (3/32") or larger, Length 5 m (200 inch) or shorter Tubing for AD37, 47(N)-D: I.D. 4 (3/16") or larger, Length 5 m (200 inch) or shorter Tubing for AD38, 48(N)-D: I.D. 6.5 (1/4") or larger, Length 5 m (200 inch) or shorter 8) Pipework for auto drain discharge which rises higher than the auto drain outlet should be avoided.
Selects the time to hold the input signal. 15 ms 200 ms Memorizes the number of times the input device is ON. Generates error per channel when the operation count exceeds the set value. 3 Enable Generates an error.
, 250, 300, 350, 400, 450, 500 Replacement Parts: Seal Kits 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Contents Kit No. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1 pc.
JIS symbol Minimum Operating Pressure Unit: MPa Bore size (mm) Minimum operating pressure 20 25 32 40 50 63 80 100 0.02 0.01 Standard Stroke Table Replacement Parts: Seal Kits Bore size (mm) Bore size (mm) 20 25, 32, 40, 50, 63, 80, 100 Standard stroke (mm) Note 1) Contents Kit No. 25, 50, 75, 100, 125, 150, 200 25, 50, 75, 100, 125, 150, 200, 250, 300 20 25 32 40 50 63 80 100 CG1Y20-PS CG1Y25
300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400500 1000 1500 Piston speed mm/s Piston speed mm/s Piston speed mm/s Piston speed mm/s Features 6
or less 0.02/200 or less 0.02/200 or less 0.02/200 or less Simplified Selection Flow Chart Simplified Selection Flow Chart Simplified Selection Flow Chart Single Axis Electric Actuator Series LTF (AC Servomotor) Single Axis Electric Actuator Series LTF (AC Servomotor) Work load kg Maximum speed mm/s Positioning repeatability mm Guide type Motor type Lead screw Series Capacity Brake Ground
For Air Upstream pressure of valve P1 1.0 MPa 1.0 Downstream pressure of valve (P2) MPa Downstream pressure of valve (P2) MPa 0.8 Subsonic Critical pressure 0.9 0.6 0.7 0.8 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500
Piston seal NBR Valve seal Non-lube Tube gasket CS1N125A-PS 125 140 160 180 200 CS1N125A-PS CS1N140A-PS CS1N160A-PS CS1N180A-PS CS1N200A-PS CS1N140A-PS Piston gasket Component part numbers: @8, #0, #1, #2, #3, #5.