SMC Corporation of America
Elite Part Number Search
Search Results "AS2001FM-07"

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow

Indicator: S, Control Method: E (Meter-out), Stud Position: B (Left Side), Tube Diameter: 07 (ø1/4"), Thread: N (NPT), Port Size: 01 (1/8)

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)],

. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 6 (-100 to 100 kPa, SI Unit only, w/Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch)

. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 6 (-100 to 100 kPa, SI Unit only, w/Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch)

Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch

. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 5 (-100 to 100 kPa, w/ Unit Selection, w/Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch), Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: E (Vacuum Break Flow Adjustment Needle Screwdriver

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment

. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 5 (-100 to 100 kPa, w/ Unit Selection, w/Energy Saving), Connector: L3 (without connector), Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch), Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual Release Pressure Supply: D [With Individual Release Pressure Supply (

.: 07 (ø1/4"), Actuator Type: 33 [Push Button (Flush)], Suffix: G (Push Button Selector Color Green), Indicator: None, Bracket: B (w/Bracket Included)

Stations: 07 (Stations), Wiring: F (D-sub Connector), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: K (Vacuum Break Flow Adjusting Needle, Screwdriver

Body Class: 3 (Orifice Diameter ø8), Valve Type: 0 (Normally Closed), Applicable Tube OD: 11 (3/8), Port B OUT: 07 (NPT1/4), Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5, 6 - Rc1/8, Material: Body PFA, Actuator Endplate PPS, Diaphragm PTFE, Option: 1 (Flow Rate Adjustment)

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch

Single Unit - Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)]

. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 5 (-100 to 100 kPa, w/ Unit Selection, w/Energy Saving), Connector: L3 (without connector), Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch), Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]