Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting), Option 3: T (w/o Operation Manual, Calibration Certificate)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: C6L (One-touch Fitting ø6mm, Elbow Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover), Option 3: T (w/o Operation Manual, Calibration Certificate)
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)1 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 4 to 20 mA ?2.5% F.S.?
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?
This is a legacy product, and replaced byISE20C-T-A2-W-X502, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DX, ISE40/50/60 1/4 (MISC.
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)1 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 4 to 20 mA ?2.5% F.S.?
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?
1-C6 ind supply spacer, VQ1000/VQ20/VQ30 VALVE*** $59.55 + Add to Quote Add To Cart Add to Cart SMC VVQ1000-P-1-N7 ind supply spacer, VV5Q* MANIFOLD VQ 4/5 PORT*** $56.55 +
Refer to P.18 for assembling method. PNP output Conversion cable M8 8 Pin connector (Plug) PIN No.
Refer to P.18 for assembling method. NPN output M8 8 Pin connector (Plug) PIN No.
Load voltage 12 to 24 VDC10%, Ripple(p-p) 10% or less If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system Check the product regularly for proper operation Otherwise malfunction can result, causing an accident. 5 to 40 mA Load current Leakage current 1 mA or less Int. voltage drop 5 V or less The following instructions must
For more than 6 stations, supply air from both P ports on. For common exhaust type, exhaust from both R ports. 2. P and R ports can be 3/8 by mounting the optional mounting bracket to the manifold base. Mounting When mounting valves on the manifold base, the mounting orientation is decided. If it is mounted in the wrong direction, connected equipment may malfunction.
Supply(P),Vacuum(V), One-touch Fitting: N (Supply (P) Port: ø1/4"; Vacuum (V) Port: ø1/2"), Exhaust Type: Silencer Exhaust, Supply/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking
5 u t !8 @1 r @4 w 12 to 40 @7 !1 !7 q !6 !0 @2 @3 o @4 @6 y e r !8 @1 @5 u w Rod cross section for 12, 16, 20, and 25 Rod cross section for 32 and 40 With end lock 12 to 40 y !7 !6 q !0 o @2 @3 @4 @6 e r !8 @5 @1 i @8 !4 !5 !2 @9 !3 w Parts list No. 1 2 3 4 5 No. Description Rod cover Head cover Cylinder tube Piston Spacer for switch type Description Qty. Note Material Qty.
For vacuum equipment precautions, refer to the Handling Precautions for SMC Products and the Operation Manual on the SMC website: http://www. smcworld.com Nozzle diameter Port size 05 0.5 mm 07 0.7 mm Nil 6 One-touch fitting 01 Rc1/8 female thread Symbol EXH Vacuum pressure reached S 90 kPa L 48 kPa Mounting P V Caution Specifications 1 .
EX##-OMF0012 10 EX##-OMF0012-A No.EX-OMF0012-B -11- 6. Wiring 6-1 Communication line There are two connection types are available for slave of CompoBus/S, which are T branch and Multi drop. In T branch, slave is connected to stay branched from trunk and in Multi drop, slave is connected directly to trunk. However, in both types, it is impossible to branch from stay.
B AR20-B AR40-B AR25-B Differential pressure gauge GD40-2-01-X29 Y30(T)-A Y30(T)-A Y20(T)-A Y40(T)-A Spacer Y40(T)-A Y20(T)-A Fluid Compressed Air Range of operating conditions Inlet air pressure MPa 0.3 to 1.0 0.3 to 0.85 0.3 to 1.0 0.3 to 0.85 Inlet air temperature oC -5 to 55 -5 to 50 -5 to 55 -5 to 50 *Note1 Ambient temperature oC -5 to 55 -5 to 50 -5 to 55 -5 to 50 *Note1 Standard Performance